The HYHX-500J nuclear phase detector function verification device is a necessary testing equipment for verifying the accuracy of high and low voltage nuclear phase detectors. This device is a nuclear phase analyzer function detection device independently developed by our company, utilizing our years of expertise in the field of nuclear phase analyzer research and development. It has adjustable voltage, frequency, phase angle, and high output accuracy.
productfeature:
1. The whole machine is controlled by a high-speed microcontroller, with a high degree of automation and easy operation.
2. The instrument is brand newInverter power technology, outputting stable and adjustable low-frequency AC power.
3、Can simulate the high-pressure environment on site and obtain real data of the tested instrument.
4、Maximum output capabilityAC voltage with effective value of 1500V, adjustable frequency and phase.
5、During high voltage output, there are indicator lights and alarm sounds to warn operators to stay away.
6. Equipped with a hardware emergency stop button, it can ensure the normal stop output function in case of screen failure or other situations.
8The instrument is equipped with a high-energy lithium battery inside, which can work continuously for a long time without the need for an external power supply, making it convenient for indoor and outdoor use.
9. Supports both Chinese and English interfaces.
Technical Indicators:
1Measurement range:
Technical Specifications |
Parameter requirements |
Output AC voltage (effective value) |
100V/200V/400V/600V/
800V/1000V/1200V/1500V
|
Voltage accuracy |
≤2% |
output frequency |
45~65Hz |
Frequency accuracy |
≤0.1% |
Output phase angle difference between two power sources |
0°~359.9° |
Phase stepping |
0.1°/0.5°/1°/5°/10°/30° |
Phase accuracy |
0.1° |
2、battery parameters:DC11.1 V/6000mAH;
3、Charging parameters:DC12.6V2A
4Working temperature:-10~50℃
5Working humidity:<80%RH
6External dimensions: Long365mmX width269mmX高169mm
7Weight:6kg