- Phone
-
Address
21-1 Changjiang Road, Wuxi City, Jiangsu Province
Wuxi Dongyuan Instrument Technology Co., Ltd
21-1 Changjiang Road, Wuxi City, Jiangsu Province
Nine parameters of micro water stationAdopting an integrated design principle, it includes a water collection and distribution system, a detection unit (five measurement modules for total phosphorus, total nitrogen, chemical oxygen demand, permanganate index, ammonia nitrogen, and conventional five parameters), a quality control unit, and auxiliary units (waste liquid collection, lightning protection, air conditioning, etc.). The core unit is the detection unit, which includes total phosphorus, total nitrogen, chemical oxygen demand, permanganate index, ammonia nitrogen, and chemical analysis methods strictly following national standards. The conventional five parameter indicators (dissolved oxygen, conductivity, turbidity, temperature, pH) are measured using a multi electrode integration method.
Nine parameters of micro water stationTechnical parameters:
Detailed parameter information | ||
|
Conductivity/TDS |
measurement range |
Conductivity: 0-2000 μ S/cm, TDS: 0-4000mg/L |
measurement accuracy |
±1%F ·S |
|
resolution |
0.001:0.01 (depending on the electrode) |
|
|
pH/ORP |
measurement range |
pH:0~14pH,ORP:-2000~+2000mV |
measurement accuracy |
pH:±0.1pH,ORP:±5mV |
|
resolution |
0.001:0.01 (depending on the electrode) |
|
|
dissolved oxygen |
measurement range |
Dissolved oxygen: 0~25.00mg/L |
measurement accuracy |
Dissolved oxygen: ± 0.2mg/L |
|
resolution |
0.001:0.01 (depending on the electrode) |
|
|
Total Nitrogen |
measurement range |
Total nitrogen: 0-5mg/L, 0-50mg/L, 0-500mg/L (customizable) |
measurement accuracy |
Total nitrogen: ± 10% F.S |
|
resolution |
<0.001mg/L |
|
|
turbidity |
measurement range |
Turbidity: 0-10NTU (expandable) |
measurement accuracy |
浊度: ±5%F ·S |
|
resolution |
0.001:0.01 (depending on the electrode) |
|
|
Total Phosphorus |
measurement range |
Total phosphorus: 0-2mg/L, 0-10mg/L, 0-50mg/L (customizable) |
measurement accuracy |
Total phosphorus: ± 5% F · S |
|
resolution |
<0.001mg/L |
|
|
COD |
measurement range |
COD: 0-300mg/L, 0-1000mg/L (customizable) |
measurement accuracy |
COD:±5%F ·S |
|
resolution |
<1.0mg/L |
|
|
ammonia nitrogen |
measurement range |
Ammonia nitrogen: 0-1000mg/L |
measurement accuracy |
Ammonia nitrogen: ± 5% F · S |
|
resolution |
<0.002mg/L |
|
|
temperature |
measurement range |
0~100℃ |
measurement accuracy |
±0.5℃ |
|
resolution |
0.1℃ |
|
Communication output |
Two RS485 interfaces, Modbus protocol |
|
power supply |
85~265VAC,50/60Hz |
|
working conditions |
Temperature 0-45 ℃, humidity not exceeding 85%, no electromagnetic field interference |
|
Installation method |
Cabinet style |
|
process connection |
Water sample inlet: DN15 or hose 4 × 6mm; Water sample discharge outlet: DN15 |
|
Body dimensions |
1200×400×500mm |
|