Welcome Customer !

Membership

Help

Zhengzhou Huatu Biotechnology Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Zhengzhou Huatu Biotechnology Co., Ltd

  • E-mail

  • Phone

  • Address

    702, Building C, Triumphal Arch, No. 238 Tongbai South Road, Zhongyuan District, Zhengzhou City, Henan Province

Contact Now

Networked gas chromatograph

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The GC-2090 networked gas chromatograph is equipped with EPC and EFC control systems for the entire system. This system is designed and manufactured as a gas micro flow control system using high-precision proportional valves, pressure sensors, and flow sensors. Compared to traditional mechanical valve control methods, it greatly improves the accuracy of gas pressure and flow control, enhances the automation level of instruments, eliminates the shortcomings of traditional mechanical valves that cannot compensate for temperature, and thus improves the overall performance of instruments!

Product Details

GC2090 typeNetworked gas chromatograph

The entire system is equipped with EPC and EFC control systems, which are designed and manufactured as gas micro flow control systems using high-precision proportional valves, pressure sensors, and flow sensors. Compared to traditional mechanical valve control methods, it greatly improves the accuracy of gas pressure and flow control, enhances the automation level of instruments, eliminates the shortcomings of traditional mechanical valves that cannot compensate for temperature, and thus improves the overall performance of instruments!

Anti control chromatography workstation
Unlike ordinary gas chromatographs, it requires a 10/100M adaptive network environment (when remote data transmission through the Internet is required, Internet access services are also required) and a set of computers with Chinese Windows 2000, XP, win7, and win8 operating systems.

Building a network environment is very simple. If the user's laboratory already has a network environment (with IP remaining in this network environment), the instrument can be directly connected to this network using Ethernet cables. If the user's laboratory does not have a network or intends to isolate the instrument's network from the office network, a network can be constructed using switches, HUBs, etc. Switches, HUBs, etc. can be purchased from local computer stores, or from manufacturers or distributors when ordering instruments.

The reverse control chromatography workstation can modify and set any parameters within the GC2090 host.


GC2090 typeNetworked gas chromatograph

Main technical indicators

Operation display: 8-inch color LCD touch screen

Temperature controlled area: 8 channels

Temperature control range: 4 ℃ to 450 ℃ above room temperature, increment: 1 ℃, accuracy: ± 0.1 ℃

Program heating order: 20 orders

Cheng Sheng rate: 0.1-60 ℃/min

Gas path control: Full electronic pressure (EPC), electronic flow control (EFC)

Range: 0-100psi (pressure); 0-1000mL/min (flow rate)

Resolution: 0.01Psi (pressure); 0.01 mL/min (flow rate)

External events: 8 channels; Control output 2 channels

Sample injector types: packed column injection, capillary injection, six way valve gas injection, automatic injector

Number of detectors: 3 (the most); FID, TCD, ECD, FPD, and NPD are optional

Start injection: manual or automatic options available

Communication interface: Ethernet: IEEE802.3


GC2090 typeNetworked gas chromatograph

[Precautions for Operation]

During the operation or shutdown of the instrument, components such as the injector, detector, column box, and rear air outlet may experience certain high temperatures, and should be avoided from coming into contact with them to prevent damage. If parts need to be replaced, be sure to wait until the instrument temperature drops or after using protective measures!

Pay attention to the burning gas emitted during instrument cooling to prevent tank damage;

Flammable materials are strictly prohibited from being placed on the back of the instrument to prevent the release of hot gases from igniting flammable materials!

PVC and other gas pipelines should avoid the rear air outlet of the instrument to prevent the burning gas from melting the gas source pipeline and causing danger! Gas source hazard:

For the gas cylinders and sources used in the instrument, relevant regulations on gas cylinder transportation, storage, management, and overall use should be followed.