E-mail
info@wyoptics.cn
-
Phone
15921374716
-
Address
No. 199 Jiangkai Road, Building 1, 101
Shanghai Wenyi Optoelectronics Technology Co., Ltd
info@wyoptics.cn
15921374716
No. 199 Jiangkai Road, Building 1, 101
Wide wavelength 900-2500nm/transient 0.1ms spectral acquisition/deep cooling detector/small volume
IR seriesNear infrared spectrometerIt is a near-infrared spectroscopy analyzer with built-in cooling, using high-speed InGaAs CCD and integrating a step filter to eliminate high-order diffraction. It can cover the entire near-infrared spectrum of 900-2500nm and is suitable for near-infrared online spectral detection, laboratory portable near-infrared detection, and microscope combined near-infrared detection.
IR seriesNear infrared spectrometerHas the following significant characteristics:
1 Transient 0.1 ms spectral acquisitionIR seriesspectrometerUsing Hamamatsu arrayed InGaAs detectors, which are different from traditional scanning spectrometers, can collect spectra at the millisecond level and are very suitable for quickly completing experimental ideas in the laboratory;
2 900~2500nm wide spectrumThe IR series spectrometer covers multiple detection bands in the near-infrared region, providing multiple bands such as 900-1700nm, 900-2200nm, 900-2500nm, etc., to meet diverse sensitivity and band requirements;
3 Deep TEC refrigerationIR seriesspectrometerAdopting chip level internal cooling technology to deeply cool InGaAs detectors and effectively solve the problem of low-temperature condensation, the signal-to-noise ratio is increased to 5500:1 level;
4 IR seriesspectrometerThere are 256 pixel and 512 pixel detectors to choose from, with higher pixel resolution.
The cooling temperature can reach -20 ℃. Has good spectral response stability and reproducibility, suitable for laser measurement and near-infrared measurement. It is a high-performance fiber optic spectrometer for scientific research and development.
| model | IR1700 | IR1700-Pro | IR2500 | IR2500-Pro | |
| pixel | 256 pixels | 512 pixels | 256 pixels | 512 pixels | |
| TE-Cooled | First-order refrigeration | Second stage refrigeration | |||
| Wavelength Range | 900 - 1700 nm | 900 - 2500 nm | |||
| optical resolution | Slit 50um | ~8nm | ~5.5nm | ~15nm | ~10nm |
| Slit 100um | ~10nm | ~7nm | ~20nm | ~14nm | |
| integration time | 100 μs ~ 24s | 100 μs -200ms | |||
| signal-to-noise ratio | 5500:1 | 3500:1 | 3500:1 | - | |
| dynamic range | 9500:1 | 9300:1 | 9300:1 | 9300:1 | |
| Dark noise | 10 | 10 | 10 | 10 | |
| stray light | < 4.55‰ @ 1000 nm | ||||
| Wavelength accuracy | <1nm | ||||
| AD sampling | 16 bit, 15MHz A/D converter | ||||
| fiber optic interface | SMA905 | ||||
| numerical aperture | 0.1NA | ||||
| focal length | 60mm | ||||
| data interface | USB2.0@480Mbps 、RS232 | ||||
| optical structure | Czerny Turner optical structure | ||||
| Overall dimensions | 130 x 96 x 58 mm | ||||
| Collection Mode | Single, continuous, software triggered, synchronous external triggered | ||||
| Extended Function Interface | 8-pin expansion port connects spectrometer to external devices | ||||
| Operating Temperature | 0℃~40℃ | ||||
| Operating Humidity | 20%-85% | ||||
Typical application areas:
Due to the diversity of samples and the complexity of testing conditions, spectrometers need to have strong system universality and adaptability for transmission, reflection, and absorption spectroscopy.
Online component analysis, such as moisture analysis in tobacco, requires a spectrometer with MS level spectral acquisition and transmission capabilities; Meanwhile, it is necessary toitsEquipped with chip level internal cooling capability to meet stability requirements.
1064nm Raman spectroscopy, film thickness, food, pharmaceutical, environmental, and biochemical detection applications.
| model | Band range selection (nm) |
Grating number (g/mm) |
Wavelength interval (nm) |
Resolution corresponding to slit width (nm) | |||||
| 25 μm | 50 μm | 100 μm | 200 μm | ||||||
| IR1700 | 900~1700 | 240 | 3.2 | - | 7.2 | 10 | 14 | ||
| IR1700 | 1080~1440 | 400 | 1.4 | 3.1 | 4 | 5.5 | 7.5 | ||
| IR1700-Pro | 900~1700 | 240 | 1.6 | 4.2 | 5.2 | 7 | 14 | ||
| IR2500 | 900~2500 | 120 | 6.3 | - | 15 | 21 | 30 | ||
| IR2500-Pro | 900~2500 | 120 | 3.2 | - | 12 | 18 | 28 | ||
| You can also customize the required wavelength according to user requirements | |||||||||