NS5928 rack mounted gigabit network managed industrial Ethernet switch fully meets the security requirements of the State Grid. NS5928 provides 24 10/100M adaptive Ethernet interfaces and 4 1000M SFP expansion slots for gigabit uplink or gigabit backbone ring network construction, with flexible port configuration and good expansion performance. NS5928 network managed Ethernet switch provides full line speed non blocking forwarding, IEEE802.3x flow control in full duplex mode, and backpressure flow control in half duplex mode. It can form a fast recovery self-healing ring network with a self-healing time of less than 20ms, providing strong guarantee for user network security and supporting automatic detection and switching of the ring. NS5928 provides rich network management functions, supports NLK ring fast ring network, is compatible with STP/RSTP/MSTP spanning tree protocol, port based VLAN, 802.1Q based VLAN, QoS, IGMP Snooping, broadcast storm suppression, port aggregation, port mirroring, port status management, SNMP, NTP timing, etc. At present, this product is widely used in industrial harsh environments such as intelligent transportation, energy wind power, pipe gallery tunnels, intelligent substations, etc. Deploy type II network security monitoring devices in the security zone II (or zone I) of power monitoring systems in power plants and grid connected substations to monitor and manage network security incidents. At present, the Type II network security monitoring device can achieve monitoring and alarm of the main equipment, network equipment, general and special security equipment related to the network in substations and power plants. It can real-time grasp the security events such as peripheral access, network equipment access, and personnel login of the internal network hosts in substations and power plants. After long-term testing and operation, the equipment is in a stable state and meets the security prevention and control goals of "effective containment of internal intervention and effective control of security risks".
|
attribute |
NS5928 |
|
interface |
24 10/100M adaptive Ethernet interfaces 4 1000M SFP expansion slots |
|
Network cable type and distance |
Twisted pair cable supports a transmission distance of 100m |
|
Optical port attribute |
Single mode 1310nm, multimode 850nm; single mode 20km, multimode 550m (long-distance modules can be customized) |
|
Process type |
store and forward |
|
MAC address table size |
Supports 8K MAC addresses Support black hole MAC addresses Support setting the maximum number of port MAC address learning Support static multicast MAC |
|
backplane bandwidth |
15.6Gbps |
|
Packet forwarding rate |
9.6Mpps |
|
Package cache |
4Mbit |
|
flow control |
Supports IEEE802.3x traffic control (full duplex) Support storm suppression based on port rate percentage Support PPS based storm suppression |
|
Ring network redundancy protocol |
Support NLK ring protocol (self-healing time<20ms) |
|
Spanning-Tree |
Support STP/RSTP/MSTP protocol Support STP Root Guard Support BPDU Guard |
|
VLAN |
Support port based VLANs (4094), 802.1Q VLANs Support GVRP |
|
Self healing ring networking method |
Support multiple self-healing rings Support tangent rings |
|
Link Aggregation |
Support static aggregation and dynamic aggregation |
|
Jumbo fr |
Support, maximum frame length is 9K |
|
DHCP |
Support DHCP Client |
|
Broadcast/multicast/unicast storm suppression |
Support storm suppression based on port rate percentage |
|
Multicast |
Support IGMP Snooping |
|
QoS |
Support limiting the rate at which ports receive and send messages, with a granularity of 8Kbit/s Each port supports 8 output queues Supports flexible queue scheduling algorithms that can be set based on both ports and queues, supporting SP, WRR, and SP+WRR |
|
ACL |
Provide based on source MAC address, destination MAC address, and source IP (IPv4) |
|
Port Mirror |
Support port mirroring |
|
network security |
Support user level management and password protection Support AAA certification Support Radius authentication Supports port isolation |
|
802.1X |
Support port based authentication and MAC based authentication |
|
Upgrade and Configuration |
Support FTP/TFTP/WEB upgrade log recording configuration file download and upload |
|
Alarm output |
Support power alarm |
|
manage |
Support command-line interface (CLI) configuration Support Telnet remote configuration Support configuration through Console port Support SNMP |
|
maintenance |
Support Ping Support Telnet remote maintenance |
|
pilot lamp |
Power indicator: POW, interface light indicator: CPU, SPEED, li |
|
power supply |
Input voltage: AC/DC85-265V Support power loss alarm function Support power anti reverse protection Industrial Phoenix Terminal Wiring |
|
work environment |
Working temperature: -40 ℃~+75 ℃ Storage temperature: -40 ℃~85 ℃ Relative humidity: 5% to 95% without condensation |
|
Installation method |
1U rack mounted installation |
|
External dimensions |
Width x Height x Depth: 485.8mm x 44mm x 280mm |
|
protection grade |
IP40 protection level, fanless design |
|
MTBF |
350000h |
|
Warranty period |
5 years |
|
Compliant with standards |
IEEE802.3:CSMA/CD
IEEE802.3i:10ba
IEEE802.3u:100ba IEEE 802.3ad: Link Aggregation IEEE 802.3x: Full Duplex Ethernet Data Link Layer Flow Control IEEE 802.1p: Traffic Priority IEEE 802.1Q:VLAN IEEE 802.1w: Fast spanning tree IEEE 802.1X: Port based Network Access Control |
|
EMI |
Electromagnetic interference level test |
|
EMC |
IEC61000-4-2(ESD) ±8kV(contact)±15kV(air) IEC61000-4-3(RS) 10V/m(80MHz~2GHz) IEC61000-4-4(EFT) Power Port:±4kV;Data Port:±2kV IEC61000-4-5(Surge) Power Port:±2kV/DM±4kV/CM; Data Port:±2kV IEC61000-4-6(CS) 3V(10kHz~150kHz); 10V(150kHz~80MHz) IEC61000-4-16 (common mode conduction) 30V (cont.) 300V (1s) |

|
PRODUCT MODEL |
Specification parameters |
|
NS5928-24T |
24 10/100M electrical ports, supporting network management |
|
NS5928-4GX-24T |
24 10/100M electrical ports, 4 1000M SFP expansion slots, supporting network management |
|
NS5928-8AM |
16 10/100M electrical ports, 8 100M multi-mode SC/ST/FC optical ports, 1310nm, 0-2km, supporting network management |
|
NS5928-8AS |
16 10/100M electrical ports, 8 100M single-mode SC/ST/FC optical ports, 1310nm, 0-20km, supporting network management |
|
NS5928-4GX-8AM |
16 10/100M electrical ports, 8 100M multi-mode SC/ST/FC optical ports, 1310nm, 0-2km, 4 1000M SFP expansion slots, supporting network management |
|
NS5928-4GX-8AS |
16 10/100M electrical ports, 8 100M single-mode SC/ST/FC optical ports, 1310nm, 0-20km, 4 1000M SFP expansion slots, supporting network management |
|
NS5928-16AM |
8 10/100M electrical ports, 16 100M multi-mode SC/ST/FC optical ports, 1310nm, 0-2km, supporting network management |
|
NS5928-16AS |
8 10/100M electrical ports, 16 100M single-mode SC/ST/FC optical ports, 1310nm, 0-20km, supporting network management |
|
NS5928-4GX-16AM |
8 10/100M electrical ports, 16 100M multi-mode SC/ST/FC optical ports, 1310nm, 0-2km, 4 1000M SFP expansion slots, supporting network management |
|
NS5928-4GX-16AS |
8 10/100M electrical ports, 16 100M single-mode SC/ST/FC optical ports, 1310nm, 0-20km, 4 1000M SFP expansion slots, supporting network management |
|
NS5928-24AM |
24 100M multi-mode SC/ST/FC optical ports, 1310nm, 0-2km, supporting network management |
|
NS5928-24AS |
24 100M single-mode SC/ST/FC optical ports, 1310nm, 0-20km, supporting network management |
|
NS5928-4GX-24AM |
24 100M multi-mode SC/ST/FC optical ports, 1310nm, 0-2km, 4 1000M SFP expansion slots, supporting network management |
|
NS5928-4GX-24AS |
24 100M single-mode SC/ST/FC optical ports, 1310nm, 0-20km, 4 1000M SFP expansion slots, supporting network management |