NR01-L 4-composite net radiometer

NegotiableUpdate on 12/17
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The NR01-L 4-compoonent net radiometer is a research grade net radiometer that measures the energy balance of incident shortwave radiation and longwave infrared radiation relative to shortwave radiation reflected from the surface and upward longwave infrared radiation. Our data collector can measure the output signal of NR01 and control its internal heater. This net radiation meter provides a professional solution for scientific research on energy balance.
Product Details

research-grade
A robust 4-composite net radiation meter that requires minimal maintenance


NR01-L 4-composite net radiometerIt is a scientific research grade net radiation meter that measures the energy balance of incident shortwave radiation and longwave infrared radiation relative to shortwave radiation reflected from the surface and upward longwave infrared radiation. Our data collector can measure the output signal of NR01 and control its internal heater. This net radiation meter provides a professional solution for scientific research on energy balance.


Technical Specification

NR01-L 4-composite net radiometerContains paired shortwave and longwave radiation meters, with one set facing upwards and the other facing downwards. Short wave radiation meters measure short wave radiation, while long wave radiation meters measure far-infrared radiation.


NR01-L 4-composite net radiometerIt includes a built-in RTD sensor to measure the internal temperature of the radiation meter, and a 1-W heater to minimize dew generation and melting frost. In order to reduce power consumption, the heater is usually delayed in starting, only when the solar radiation is less than 20 W/m2It only starts when the time comes.

Kangbao ZhixinThe CR3000 and CR5000 data collectors are suitable for measuring this type of net radiation meter. CR1000 data collector can also be used, but a 4WPB100 module is required to measure the internal temperature of the net radiation meter.

Product Specifications

NR01-L 4分量净辐射仪