Welcome Customer !

Membership

Help

Shanghai Shupei Experimental Equipment Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Shanghai Shupei Experimental Equipment Co., Ltd

  • E-mail

  • Phone

  • Address

    506, Building B, 1018 Mingzhu Road, Qingpu District, Shanghai

Contact Now

NH2 Aminopropyl Solid Phase Extraction Column SPE Extraction Small Column

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The NH2 aminopropyl solid-phase extraction column SPE extraction column is customized by Shanghai Shupei Experimental Equipment Co., Ltd. The NH2 (amino) is an aminopropyl extraction column based on silica gel. It has a polar stationary phase and a weak anion exchanger, which can achieve retention through weak anion exchange (aqueous solution) or polar adsorption (non-polar organic solution), thus having a dual effect. When used for pretreatment in non-polar solutions (such as n-hexane), it can form hydrogen bonds with molecules containing functional groups of - OH, - NH, and - SH.

Product Details

NH2 Aminopropyl Solid Phase Extraction Column SPE Extraction Small ColumnCustomized by Shanghai Shupei Experimental Equipment Co., Ltd., NH2 (amino) is an amino propyl extraction column based on silica gel. It has a polar stationary phase and a weak anion exchanger, which can achieve retention through weak anion exchange (aqueous solution) or polar adsorption (non-polar organic solution), thus having a dual effect. When used for pretreatment in non-polar solutions (such as n-hexane), it can form hydrogen bonds with molecules containing functional groups of - OH, - NH, and - SH.

Name: NH2 Aminopropyl Extraction Column SPE Solid Phase Extraction Column Amino Column Aminopropyl SPE Extraction Column

Specification: Please refer to the parameter specification table for details:

Purpose: Extract moderately polar or acidic compounds.

Amino pKa=9.8; The interaction with anions is weaker than SCX, and in aqueous solutions with pH<7.8, functional groups carry positive charges. Can be used as a weak anion exchanger, suitable for retaining strong anions such as sulfate ions that are strongly retained on SCX. The pH range is 2-8.

NH2 Aminopropyl Solid Phase Extraction Column SPE Extraction Small ColumnDetailed parameter specification table:

name

specification

packaging

Item Number

brand

NH2 Aminopropyl Solid Phase Extraction Column

100mg/1ml

100 pieces/box

SP-NH2-1001

Shanghai Shupei

NH2 Aminopropyl Solid Phase Extraction Column

100mg/3ml

50 pieces

SP-NH2-1003

Shanghai Shupei

NH2 Aminopropyl Solid Phase Extraction Column

200mg/3ml

50 pieces

SP-NH2-2003

Shanghai Shupei

NH2 Aminopropyl Solid Phase Extraction Column

500mg/3ml

50 pieces

SP-NH2-5003

Shanghai Shupei

NH2 Aminopropyl Solid Phase Extraction Column

500mg/6ml

30 pieces/box

SP-NH2-5006

Shanghai Shupei

NH2 Aminopropyl Solid Phase Extraction Column

1000mg/6ml

30 pieces/box

SP-NH2-10006

Shanghai Shupei

NH2 Aminopropyl Solid Phase Extraction Column

2000mg/6ml

30 pieces/box

SP-NH2-20006

Shanghai Shupei

NH2 Aminopropyl Solid Phase Extraction Column

2000mg/12ml

20 pieces/box

SP-NH2-200012

Shanghai Shupei

Diagram:


NH2氨丙基固相萃取柱 SPE萃取小柱