- Phone
-
Address
Yongfeng Town Minsheng Industrial Park, Tianchang City, Anhui Province
Anhui Kanglan Electric Co., Ltd
Yongfeng Town Minsheng Industrial Park, Tianchang City, Anhui Province
NH-DJYPPV22-2 * 2 * 1.5 fire-resistant computer cableuse characteristics
Rated voltage UO/U: 300/500V
Maximum operating temperature: General type not exceeding 70 ℃
Cross linked polyethylene not exceeding 90 ℃
The maximum heat resistance of 105 ℃ shall not exceed 105 ℃
Environmental temperature: -15 ℃
Bending radius:
The cable without armor layer and shielding should not be less than 6 times the outer diameter of the cable;
Cables with armor layer or copper foil, aluminum/plastic composite tape shielding structure should not be less than 12 times the outer diameter of the cable
Model Description Table
Project code description Flame retardant code ZDDZWDZ Non flame retardant Omitted flame retardant (divided into three levels A, B, C) Low smoke, low halogen flame retardant, halogen-free, low smoke flame retardant series code DJ, J Insulation materials for electronic computers (including DCS systems) and electric instruments VYYJFVY Polyvinyl chloride polyethylene cross-linked polyethylene fluoroplastic, low smoke, low halogen polyolefin, halogen-free, low smoke polyolefin shielding material PP2P3 copper wire braided copper tape aluminum polyester composite film sheath material VYVY Polyvinyl chloride polyethylene, low smoke, low halogen polyolefin, halogen-free, low smoke polyolefin armor material 23 Steel strip armor Fine steel wire armor conductor type ABR single strand conductor seven strand stranded conductor multi strand soft strand conductor
NH-DJYPPV22-2 * 2 * 1.5 fire-resistant computer cableModel meaning:
NH: Fire resistant type, capable of maintaining normal operation of the circuit for 90 minutes in a 750 ℃ flame
DJY: Cable for electronic computers
PVP: Copper wire braided partial shielding+total shielding structure
22: Double steel belt armor enhances compressive and mechanical protection capabilities
Conductor specifications: 2 pairs (2 × 2), with a cross-sectional area of 1.5mm ² per core
Rated voltage: 300/500V
Working temperature: Long term allowable working temperature shall not exceed 70 ℃, and shall not exceed 160 ℃ during short circuit (duration ≤ 5s)
Laying temperature: should not be lower than 0 ℃, otherwise preheating is required
Bending radius: When there is an armored structure, it should not be less than 12 times the outer diameter of the cable
Execution standards: GB/T 9330, GB/T 19666 (Fire resistance standard)

Industrial control systems (such as DCS, PLC signal transmission)
Fire alarm system and emergency power supply line
Environments with high electromagnetic interference or requiring mechanical protection, such as subways, tunnels, and petrochemicals
NH-DJYPPV22-2 * 2 * 1.5 fire-resistant computer cableproduction scope
Model Rated voltage Conductor nominal cross-section mm20.50.751.01.5 Logarithms DJVPV DJVPVPDJVVP DJVPVRDJVPVPR DJVVPRDJVV DJVVR300/5001-40DJVP2V DJVP2VP2 DJVVP2DJVP3V
DJVP3VP3
DJVVP3
DJVP2VR
DJVP2VP2R
DJVVP2R
DJVP3VR
DJVP3VP3R
DJVVP3R2-401-40
DJVPV22
DJVPV22
DJVP2V22
DJVP2VP2/22
DJVP3V22
DJVP3VP3/22
DJVVP22
DJVP3/22
DJVVP2/222-401-40
Note: The production range of other models is the same as this table