N2O and CH4 analyzer (performance enhanced quantum cascade)

NegotiableUpdate on 01/30
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
GLA351-N2OM1, N2O and CH4 analyzer (performance enhanced quantum cascade), is a highly sensitive, accurate, and stable rack mounted analyzer used for reliable measurement of N2O and CH4.
Product Details

GLA351-N2OM1,N2O and CH4 analyzer (performance enhanced quantum cascade)It is a highly sensitive, accurate, and stable rack mounted analyzer used for reliable measurement of N2O and CH4.


Features and advantages

Simultaneously measure N2O and CH4

Excellent accuracy, precision, and low drift

• Optional measurement rate: max 10Hz

Only a few minutes to install and put into use

• Optional syringe injection for batch operation

• Strong ability to resist cross interference

• Ultra wide dynamic range

• Excellent reliability

Real time diagnostic function

• Durable and sturdy; The required maintenance work is minimal and the cost is low

• Easy replacement of long-term contaminated components (filters) and normally aged components (pump diaphragms)

Service engineers can diagnose and replace most other components on site

Mirror cleaning can be carried out on site without the need for time-consuming factory repairs


Overview

The GLA351-N2OM1 performance enhanced quantum cascade (EP QC) rack mounted analyzer can simultaneously measure the mole fraction of water vapor. Therefore, the analyzer can provide N2O and CO mole fractions without water vapor. It can accurately correct the dilution and absorption line broadening effects of water vapor without drying the sample or correcting based on experience.

GLA351-N2OM1,N2O and CH4 analyzer (performance enhanced quantum cascade)Designed specifically for demanding applications, it is mainly used for applications such as greenhouse gas emission research and atmospheric monitoring that require high precision, accuracy, and stability.

The ABB Performance Enhanced (EP) OA-ICOS analyzer adopts internal thermal control technology, which can achieve ultra stable measurement, and the measurement results have the characteristics of high accuracy, high precision, and low drift. In addition, only ABB's analyzer can provide reliable and guaranteed measurements when the mole fraction reaches more than 20 times the environmental level.

GLA351-N2OM1 has a built-in computer that can store data indefinitely (suitable for applications that run unattended for a long time), and sends real-time data to a data logger through analog and digital (RS232) output. This analyzer includes control and analysis software.


N2O和CH4析仪(性能增强型量子级联)

N2O和CH4析仪(性能增强型量子级联)