- Phone
-
Address
507, 5th Floor, Building 2, No. 1336 Gaobeidian Village, Chaoyang District, Beijing
Beijing Pingliyang Medical Equipment Co., Ltd
507, 5th Floor, Building 2, No. 1336 Gaobeidian Village, Chaoyang District, Beijing

Multiskan ™ Easeenzyme-linked immunosorbent assay optical filter
Multiskan ™ Easeenzyme-linked immunosorbent assay optical filter
Multiskan ™ Easeenzyme-linked immunosorbent assay optical filter
Used for Multiskan ™ Easy Absorption Microplate Reader from Thermo Scientific ™ Filter accessories expand the flexibility of analysis by achieving precise wavelength selection in a wide range of absorbance applications. These durable hard coated filters are designed to integrate smoothly with the optical system of the instrument, supporting both routine and advanced analysis while maintaining high measurement accuracy and long-term reliability.
Multiskan ™ Ease uses an easy to install 8-bit filter wheel and offers three pre installed standard filters (405 nm, 450 nm, and 620 nm). Additional filter accessories allow users to customize wavelength configurations to meet specific analytical requirements, from ELISA and protein quantification to enzyme kinetics and microbial growth analysis.
Optical Filter Wavelength and Its Typical Applications
Standard (pre installed on filter wheel):
405 nm alkaline phosphatase (ALP) enzyme-linked immunosorbent assay; ABT assay; Enzyme kinetics; Endotoxin testing method
450nm - HRP/tmb based ELISA (including rapid and real-time ELISA formats)
620nm - ELISA standard wavelength; Alternative readings for Bradford protein assay
Optional filters:
414 nm heme/hemoglobin assay, Soret band detection, selected oxidation and antioxidant capacity determination
492 nm OPD based ELISA, LDH cytotoxicity, MTS cell proliferation assay. Pierce ™ No dilution required ™ Rapid gold BCA protein assay.
520nm - Selective colorimetric assay for cell proliferation and metabolic activity determination
540nm - Determination of Nitric Oxide (Griess)
570nm - the main wavelength used for BCA protein quantification, MTT cell proliferation, and crystal violet assay
600 nm - Bacterial growth (OD600), Bradford protein assay and turbidity measurement
660nm - Pierce ™ 660nm protein assay
690nm - Reference wavelength for ELISA and MTT detection
750 nm Laurie protein assay; Reference wavelength for protein determination and turbidity correction
Key Features
Easy to install design allows for quick replacement of filters without the need for tools
Durable hard coated optical filter design for long-lasting performance and minimal maintenance
Wavelength accuracy optimization, reliable and repeatable absorbance measurement
With Multiskan ™ Ease's 8-bit filtering wheel is compatible
These optical filters and filter wheels are designed for Thermo Scientific ™ Multiskan ™ Ease Absorption Microplate Reader. They support detecting specific wavelength optimizations to improve data quality and are compatible with Thermo Scientific ™ SkanIt ™ Software integration to simplify detection settings and data analysis in existing laboratory workflows.
For research purposes only. Not applicable to diagnostic programs.
| Item Number | wavelength |
|---|---|
| MEOF0750 | 750nm |
| MEOF0414 | 414 nm |
| MEOF0492 | 492 nm |
| MEOF0520 | 520 nm |
| MEOF0540 | 540 nm |
| MEOF0570 | 570 nm |
| MEOF0600 | 600 nm |
| MEOF0660 | 660 nm |
| MEOF0690 | 690 nm |