Multi point illumination controller

NegotiableUpdate on 12/29
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The RX-390 multi-point illuminance tester consists of an illuminance sensor and a data recorder, which can be connected to a computer and comes with computer software. The system adopts embedded technology and modular structure, which can flexibly add communication and other functions according to user needs. This illuminance controller has advanced technology, high measurement accuracy, large data capacity, low power consumption, long telemetry distance, and user-friendly human-machine interface
Product Details

RX-390 Multi point Illumination Tester

1. Composed of an illuminance sensor and a data logger, it can

Connect the computer and randomly provide computer software.

The system adopts embedded technology and modular structure, which can be flexibly increased or decreased according to user needs

Corresponding modules and sensors can be combined in any way to conveniently and quickly meet the needs of various users

The power supply system can provide power to various sensors, and the wiring is simple and convenient.

The system comes with Chinese LCD display, automatic saving, real-time clock, data communication and other functions. that

The illuminance controller has advanced technology, high measurement accuracy, large data capacity, low power consumption, and telemetry distance

The advantages of distance, user-friendly human-machine interface, and high reliability are widely used in automatic control of indoor and outdoor lighting illumination

In fields such as manufacturing.

2. Technical parameters

2.1. Voltage: AC 100-240V, 50-60Hz or DC 12V (other voltage specifications can be customized);

2.2. Power: ≤ 1W, working current within 80mA at DC 12V;

2.3. Display: LCD display screen with backlight, 64 × 128 dot matrix, Chinese display;

2.4. Communication: 1 USB port, 2 RS232 ports, 2 RS485 ports; (One of which is RS485)

The port is used for connecting 485 sensors. If a 485 interface sensor is not equipped, this interface will not be led out;

2.5. Protocol: Compatible with Modbus RTU protocol;

2.6. Collection channel: By default, one illuminance sensor can be connected, and a maximum of eight can be connected (the number of channels is not limited)

Same, product prices are different.

2.7. Display window: 75mm × 44mm;

2.8. Volume: 200mm × 120mm × 75mm, (including fixed ear length of 240mm);

2.9. Weight: approximately 1kg;

2.10. Auto save data: (Calculated based on 5-channel data, can store 524288 entries)

Save once every minute for 365 days;

Save every 10 minutes for up to 10 years;

Save once per hour for up to 60 years;

2.11. 1 relay output, expandable to 2 relay outputs, with corresponding element values greater than the set value

Relay alarm output and display alarm status on the LCD screen.