Product Introduction: The $r $nINLab-2022 multi parameter water quality detector adopts a high-quality industrial plastic shell design. The whole machine is lightweight, beautiful, corrosion-resistant, acid alkali resistant, and high-temperature resistant. The instrument adopts an 8-inch ultra clear touch screen, with a built-in guided system operation and a fully Chinese operation interface, making it convenient for users to quickly operate and get started. Adopting a digestion colorimetric dual-purpose tube design, it saves reagents, simplifies processes, and pre stores dozens of conventional, heavy metal, and electrode method indicator parameter curves such as COD, ammonia nitrogen, total phosphorus, and total nitrogen,. It can be widely applied in fields such as environmental monitoring, scientific research water quality testing, production and emission monitoring and testing.
productIntroduction
InLab-2022Multi parameter water quality detector, designed with high-quality industrial plastic shell, the whole machine is lightweight and beautiful, resistant to corrosion, acid and alkali, and high temperature. The instrument adopts8-inch ultra clear touch screen, built-in guided system operation, fully Chinese operation interface, convenient for users to quickly operate and get started. Adopting a digestion colorimetric dual-use tube design, saving reagents, simplifying processes, and pre storingCOD、 Dozens of types including ammonia nitrogen, total phosphorus, total nitrogen, etcConventional, heavy metal, electrode methodIndicator parameter curve,It can be widely applied in fields such as environmental monitoring, scientific research water quality testing, production and emission monitoring and testing. This product also adopts modular programming design, which allows users to select single or multiple indicator detection indicator modules according to their needs. In the later use process, new measurement indicators can be added at any time according to the measurement requirements, maximizing user benefits.
Features
Color touch screen design, user-friendly human-machine dialogue interface, easy operation, visible digestion process, and direct reading of measured concentration;
Support adding indicators in the future, upgrading the product, and adding new detection indicators.
Using a dual-purpose digestion colorimetric tube, the water sample determination process is simple, fast, safe, and the measurement results are accurate;
Large capacity data storage, power-off protection design ensures that the instrument is not damaged and data records are not lost;
Calibration mode from 1 o'clock to 7 o'clock, automatically calculating slope, intercept, and correlation coefficient, with high measurement accuracy;
Intelligent design for fault self diagnosis, making instrument management and maintenance simple and convenient;
Using semiconductor cold light source emitters, the lifespan of the light source can reach tens of thousands of hours;
Equipped with data collection software, it can connect to a computer to export measurement data, and comes with a printer that can print measurement data and historical records;
Pre stored standard measurement curves can be easily retrieved for measurement, and self built measurement curves can also be created,Pre stored digestion programs for various indicators that need to be digested and measured, one click start digestion;
Low reagent usage, low operating costs, and strong anti-interference ability.
Temperature curve display, real-time display of the change curve of digestion temperature with digestion time during the digestion process, helping to observe and understand the temperature changes during the digestion process;
One click start digestion, the instrument preset commonly used digestion index parameters (such asCOD、 Total phosphorus, total nitrogen, etc.), select the corresponding indicators with one click to enter the digestion operation;
Splash proof protective cover, heat-resistant and anti-corrosion visual splash proof protective cover, convenient for operators to observe the real-time digestion status of water samples, ensuring operational safety;
The independent numerical numbering of the digestion well facilitates the differentiation of different water samples for digestion;
Color LCD screen, color page touch screen with full Chinese display, user-friendly operation interface;
Overtemperature power-off protection, automatic power-off protection when the set temperature is exceeded, to protect the safety of instruments and personnel;
The digestion mode can be set arbitrarily, with a wide temperature range and a large time span for digestion, improving the versatility of the instrument and meeting the different needs of different customers.
technical indicators
1Measurement indicators:COD、 Ammonia nitrogen, total phosphorus, total nitrogen, etc
2.Display mode: Color LCD touch screen, Chinese operation interface;
3Color comparison method: tubeColor comparison of formula
4.Number of curves: adjustable100Measurement curve parameters;
3.Calibration mode:1~7Point correction mode, automatically correcting curve values;
4.Record storage: storable30000The test results show that the data will not be lost when the power is cut off;
5.hit Printing: Comes with a thermal printer;
6.Data communication:USBBluetooth (optional), can upload measurement results to the computer for user statistical analysis; The measurement results can also be exported to a mobile phoneAPP;
7.Temperature control:45℃—200℃
8.Dissolved samples:15 pieces
9.Dissolving time:0-999 minutes
10.Temperature indication error:±2℃
11.Maximum power consumption:550W
12Temperature balance:≤1℃
13.Environmental temperature:(5~45)℃; Environmental humidity: Relative humidity<85%(No condensation);
14.Overall dimensions:370*250*140mm;
15.Working power supply:AC220V±10% / 50Hz;
Test indicator parameters(Any combination)
serial number |
indicator name |
Measurement range |
serial number |
indicator name |
Measurement range |
1 |
COD (High Range) |
5~10000mg/L |
25 |
barium |
0~30mg/lL |
2 |
COD (low range) |
5~150mg/L |
26 |
Total chromium |
0~10mg/L |
3 |
COD (manganese method) |
0~50mg/L |
27 |
iron |
0~50mg/L |
4 |
ammonia nitrogen |
0~50mg/L |
28 |
ferrous |
0~50mg/L |
5 |
Total Phosphorus |
0~24mg/L |
29 |
copper |
0~50mg/L |
6 |
Total Nitrogen |
0~100mg/L |
30 |
zinc |
0~20mg/L |
7 |
Nitrate nitrogen |
0~100mg/L |
31 |
nickel |
0~50mg/L |
8 |
Nitrite nitrogen |
0~6mg/L |
32 |
manganese |
0~50mg/L |
9 |
residual chlorine |
0~10mg/L |
33 |
magnesium |
0~20mg/L |
10 |
Total Chlorine |
0~10mg/L |
34 |
cadmium |
0~0.5mg/L |
11 |
Chlorine dioxide |
0~5mg/L |
35 |
cobalt |
0~0.5mg/L |
12 |
hexavalent chromium |
0~5mg/L |
36 |
dissolved oxygen |
0~20mg/L |
13 |
chroma |
0~500Hazen |
37 |
PH |
0~14 |
14 |
turbidity |
0~400NTU |
38 |
conductivity |
0~200Ms/cm |
15 |
suspended solids |
0~500mg/L |
39 |
temperature |
-20~120℃ |
16 |
sulfate |
0~200mg/L |
40 |
ORP |
-2000~+2000mV |
17 |
sulfide |
0~12mg/L |
41 |
TDS |
0~50000mg/L |
18 |
fluoride |
0~12mg/L |
42 |
salinity |
0~5% |
19 |
aniline |
0~20mg/L |
43 |
hardness |
0~100mg/L |
20 |
phosphate |
0~24mg/L |
44 |
Volatile phenol |
0~25mg/L |
21 |
ozone |
0~2mg/L |
45 |
chloride ion |
0-100mg/L |
22 |
formaldehyde |
0~10mg/L |
46 |
Total alkalinity |
0-1200mg/L |
23 |
QIN compound |
0~0.5mg/L |
|
|
|
24 |
Anionic surfactant |
0~40mg/L |
|
|
|