Sampling KitMulti functional portable sample collection and processing boxApplication:
When accidents such as fires, illegal attacks, and large-scale pollution incidents occur, there will inevitably be leaks of chemical substances and pollution of water bodies, soil, etc. At this time, firefighters or environmental inspectors need to conduct on-site analysis of gases, water, and soil at the accident site. There is an urgent need for a portable sampling kit that can collect various forms of samples, enrich, extract, and filter them, and directly inject them into GC/MS for detailed analysis. The Sampling Kit is designed for this purpose.
Due to its special fluidity and diffusivity, the collection of gas samples has always been a challenge for testing personnel. The traditional method is to use sampling bottles or bags to collect gas through natural diffusion. Although this method can solve certain problems, its operability is poor and the operation time is relatively long. The Sampling Kit uses solid adsorption and liquid-phase extraction methods to actively adsorb or dissolve gas samples for preservation purposes, effectively solving the problem of rapid and efficient collection and preservation of gas samples.
Sampling KitMulti functional portable sample collection and processing boxTwo emergency response methods:
The Sampling Kit collects and processes samples in two ways for different states. For gaseous samples, specific adsorbents are used for adsorption, and then the adsorption is desorbed by heating to achieve the purpose of sample collection and processing. For liquid and solid samples, generally referring to water and soil samples, they are first stored in certain containers and sealed equipment, and then extracted with specific solvents.
Adsorption method:
The main determining factor of adsorption method is the selection of adsorption fillers, and the Sampling Kit has multiple types of adsorption fillers to choose from.
The Tenax TA adsorption tube has a wide range of applications, and its adsorption effect on volatile organic compounds is very good. The single recovery rate of benzene and toluene standard gases can reach over 95%, and the recovery rate of xylene and styrene standard gases can reach 90%.
When the boiling point of the detected compound is very high, multiple adsorbents can be used in combination to achieve the desired adsorption effect. The Sampling Kit provides three adsorbents for combined use: Tenax TA, Carboxen 569, and Carbobelieve SIII.
The adsorption capacity of the sample is determined by the type and concentration range of the adsorbed sample. In general, the adsorption capacity of the Sampling Kit is 1L. When the concentration of the sample is very high, excessive gas may cause damage to the adsorbent packing. In this case, the adsorption capacity can be reduced to 100ML to protect the adsorbent.
After sample adsorption, it can be directly injected into GC/MS for analysis using a desorption device.
Extraction method:
After water and soil samples are collected, they can be extracted using n-hexane, acetone, etc., and then analyzed using GC/MS.
The standard sampling module of the Sampling Kit: The standard sampling module refers to the sampling program and method set by the Sampling Kit according to the characteristics of the sample in different emergency situations, and is equipped with corresponding tools and containers (adsorbents, sampling tubes, syringes, etc.).
Method WL: Water sample module containing volatile components
3 glass bottles for sampling and extraction
3 blowing and capturing devices
-Equipped with PTFE sealing nut and glass sealing cover, used for tightening the sleeve of the sampling tube joint.
2. Method WE (Water liquid extraction) water sample module containing dissolved substances
3 extraction bottles
3 sealing covers
3 pipettes
3. Method BL Soil Sample Sampling Module Containing Volatile Substances
3 250ml glass volumetric flasks
3 headspace gas seal plugs
Nut with PTFE seal
A cartridge with a joint locking nut and a joint sleeve.
4. Method BE contaminated soil sampling module
5 soil sample collection test tubes
5 PTFE sealing plugs
test tube rack
5. Method OF Surface Solid Sampling Module
5 solid sampling test tubes
5 semi-solid sampling test tubes
6 . Method LS gas sampling module
Individual internal operating standards
5 pollutant sampling test tubes
Standard sample collection and processing plan:
For some specific situations, Sampling Kit provides specialized solutions for sample collection and processing.
100ml methanol; 100g/ml deuterated isotopes D6 benzene, D8 toluene, D10 xylene, D8 naphthalene.
250ml n-hexane; 20g/ml deuterium isotopes D8 naphthalene, D10 anthracene, and d10 pyrene.
250m acetone; 20g/ml deuterium isotopes D8 naphthalene, D10 anthracene, and d10 pyrene.