MQY301Multi channel automatic flash evaporation sampling systemComposed of 5 airbags and 1 liquid injection, airbag sectionUsed to extract gaseous samplesQuantitativeBatch automatic injection into gas chromatograph. Mainly used for environmental air detection, cooling tower emissions, tobacco smoke, soil moisture sampling, and petrochemical gas analysis. The number of injection points is optional and comes standard with hanging5Sampling airbags (customized for other quantities). Gaseous samplepassvacuum pumpExtract, fill the quantitative ring of the internal injection valve of the instrument, and then transfer the sample toInjection of chromatograph口The supported brands include but are not limited to Agilent, American Thermal Power PE、 Shimazu and others.
Liquid injection is used for pre-treatment of liquid hydrocarbon substances before analysis, to determine the composition of C1 to C5 hydrocarbons. It allows a small stream of liquid to enter a high-temperature zone, where the sample is flash evaporated. The pressure generated during the flash evaporation process can allow gaseous samples to be injected into the gas chromatograph. Because the temperature in the high-temperature zone can be controlled by the user, it is possible to achieve flash evaporation for multiple samples and ensure reproducible analysis.
Instrument features:
u can be performed5 routesBatch injection of airbags,1 liquid sample injection
u Independently developed software control;
u Chromatography and data acquisition software can be enabled;
u Capable of controlling chromatographic instruments for sequential injection;
u Flash evaporation temperature and heat tracing temperature can be independently controlled, with the highest temperature230℃,Accuracy ± 0.1℃
u Liquid injection pressure: 100-400psi;
u sampleHeat tracing output,Ensure that the sample does not condense;
u usePassivation treatment pipeline to prevent sample adsorption or corrosion
u instrumentbuilt-ingasInjection valve,Realize quantitative injection
feature |
Technical Specifications |
Number of injection ports |
6 positions,5 air bags, 1 liquid bag |
Connecting pipelines |
passivationpipeline |
External interface |
AUX、 Touch control |
power supply |
220 V 50Hz |
power |
300w |
Overall dimensions |
400255* 300mm |
Net weight |
15kg |