mud flow rate meterProduct features:
1. Measurement is not affected by changes in fluid density, viscosity, temperature, pressure, and conductivity;
2. There are no obstructing flow components or pressure loss inside the measuring tube, and the requirements for straight pipe sections are relatively low;
3. Series nominal diameter DN15~DN3000. There are multiple options for sensor lining and electrode materials;
4. The converter adopts a novel excitation method, with low power consumption, stable zero point, and high accuracy. The flow range can reach 1500:1;
5. The converter can be integrated or separated from the sensor;
6. The converter adopts a 16 bit high-performance microprocessor, 2x16 LCD display, convenient parameter setting, and reliable programming;
7. The flowmeter is a bidirectional measurement system equipped with three integrators: forward total, reverse total, and differential total; Can display. Zhuang, reverse flow, and have multiple outputs: electric
Flow, pulse, digital communication HART;
8. The converter adopts surface mount technology (SMT) and has self checking and self diagnostic functions;
Technical parameters of mud flowmeter
| Nominal diameter (mm) (Special specifications can be customized) | Pipeline type PTFE lining: DN10~DN1200 | |
| Pipeline rubber lining: DN40~DN1200 | ||
| Flow direction: | Positive, negative, net traffic | |
| Range ratio: | 150:1 | |
| Repetitive error: | ± 0.1% of the measured value | |
| Accuracy level: | Pipeline type: 0.5 level, 1.0 level | |
| Temperature of the tested medium: | Ordinary rubber lining: -20 to+60 ℃ | |
| High temperature rubber lining: -20 to+90 ℃ | ||
| PTFE lining: -30 to+100 ℃ | ||
| High temperature PTFE lining: -20 to+180 ℃ | ||
| Rated working pressure: (High voltage can be customized) | DN6-DN80:≤1.6MPa | |
| DN100-DN250:≤1.0MPa | ||
| DN300-DN1200:≤0.6MPa | ||
| Flow rate range: | 0.1-15m/s | |
| Conductivity range: | The conductivity of the measured fluid is ≥ 5 μ s/cm | |
| Current output: | load resistance | 0~10mA:0~1.5kΩ |
| 4~20mA:0~750 kΩ | ||
| Digital frequency output: | The upper limit of the output frequency can be set within 1-5000Hz with a transistor collector open circuit bidirectional output with photoelectric isolation. When the external power supply is ≤ 35V and conducting, the maximum current at the collector is 250mA | |
| Power supply: | AC220V, DC24V or 3.6V batteries | |
| Require the length of the straight pipe section | Upstream ≥ 5DN, downstream ≥ 2DN | |
| Connection method: | The flowmeter and piping are connected by flanges, and the flange connection size should comply with the provisions of GB11988 | |
| Explosion proof grade: | mdIIBT4 | |
| Protection level: | IP65, Specially customized up to IP68 | |
| Environmental temperature: | -25~+60℃ | |
| Relative temperature: | 5%~95% | |
| Total power consumption: | Less than 20W | |
instrument selection
mud flow rate meter
1. Selection code:
| model | describe | |||||||||
| GC-LDE — | □ | □ | -□ | □ | □ | □ | □ | □ | -□ | |
| orifice |
|
|
|
|
|
|
|
|
| 10-2200mm |
| combination | S | All-In-One | ||||||||
| L | Split type | |||||||||
| Electrode material | M | stainless steel | ||||||||
| T | Ti (titanium) | |||||||||
| D | Ta (tantalum) | |||||||||
| H | Hastelloy alloy | |||||||||
| P | Pt platinum | |||||||||
| N | Ni nickel | |||||||||
| Output | 0 | no-output | ||||||||
| 1 | 4-20mA/1-5KHz | |||||||||
| 2 | 4-20mA | |||||||||
| Lining material | X | rubber | ||||||||
| F | PTFE | |||||||||
| P | polyethylene | |||||||||
| J | polyurethane | |||||||||
| local display | 0 | No on-site display | ||||||||
| 1 | local display | |||||||||
| Communication method | 0 | No communication | ||||||||
| 1 | RS485 | |||||||||
| 2 | RS232 | |||||||||
| 3 | Mobdus | |||||||||
| 4 | Hart | |||||||||
| grounding | 0 | No grounding ring | ||||||||
| 1 | There is a grounding ring | |||||||||
| 2 | There is a grounding electrode | |||||||||
| Maximum traffic limit | (n) | Upper limit flow rate (range) m3/h | ||||||||
Selection of lining:
| Lining material | Performance | scope of application |
| chloroprene rubber Neoprene | Good wear resistance, excellent elasticity, high tensile strength, and resistance to corrosion from low concentration acid-base salt media, but not resistant to corrosion from oxidizing media. | <80 ° C, general water, sewage, mud, slurry |
| polyurethane Polyurethane | Has excellent wear resistance, but slightly inferior acid and alkali resistance. | <60 ° C, neutral and strongly worn mineral slurry, coal slurry, and mud. |
| PTFE PTFE | A material with the most stable chemical properties, capable of withstanding boiling hydrochloric acid, sulfuric acid, nitric acid, aqua regia, concentrated alkali, and various organic solvents, but not resistant to chlorine trifluoride and high-temperature sulfuric acid. | <180 ° C, strong corrosive media such as concentrated acid and alkali, sanitary media. |
| F46 | Chemical stability, electrical insulation, lubricity, non adhesiveness, and non flammability are similar to PTFE, but F46 material has better strength, aging resistance, temperature resistance, and low-temperature flexibility than PTFE. Good adhesion to metal, better wear resistance than PTFE, with good performance | <180 ° C, hydrochloric acid, sulfuric acid, aqua regia, and strong oxidants, sanitary media |
Selection of electrode materials:
| material | Corrosion Resistance |
| 316L | For nitric acid, sulfuric acid at room temperature<5%, boiling phosphoric acid, alkaline solution; Under certain pressure, media such as sulfurous acid, seawater, and acetic acid have strong corrosion resistance. |
| Hastelloy HB | Resistant to all concentrations of non oxidizing acids, bases, and non chlorinated hydrochloric acids such as hydrochloric acid, sulfuric acid, and organic acids at boiling point. |
| Hastelloy HC | Resistant to oxidizing acids such as nitric acid, mixed acids, or mixtures of chromic acid and sulfuric acid, as well as oxidizing salts and seawater |
| titanium | It can withstand corrosion from seawater, various chlorides and hypochlorites, oxidizing acids (including fuming nitric acid), organic acids, alkalis, etc. It is not resistant to corrosion from relatively pure reducing acids (sulfuric acid, hydrochloric acid), but corrosion is greatly reduced when the acid contains oxidants (such as nitric acid and media containing Fe and Cu ions). |
| tantalum | It has excellent corrosion resistance similar to glass, and can withstand almost all chemical media (including boiling point hydrochloric acid, nitric acid, and sulfuric acid below 175 ° C) except concentrated sulfuric acid. It is not resistant to corrosion in alkali. |
Selection of measuring caliber and flow rate
| Nominal diameter (mm) | Measurable flow range (m3/h) | Effective measurement flow range (m3/h) | Nominal diameter (mm) | Measurable flow range (m3/h) | Effective measurement flow range (m3/h) |
| 10 | 0.0142~3.3912 | 0.0848~2.826 | 300 | 12.717~3052 | 76.302~2543 |
| 15 | 0.0318~7.6302 | 0.1908~6.3585 | 350 | 17.31~4154 | 103.86~3461 |
| 20 | 0.0566~13.5648 | 0.3392~11.304 | 400 | 22.61~5425 | 135.65~4521 |
| 25 | 0.0883~21.195 | 0.5298~17.6625 | 450 | 28.62~6867 | 171.68~5722 |
| 32 | 0.1447~34.7258 | 0.8682~29.9382 | 500 | 35.33~8478 | 211.95~7065 |
| 40 | 0.2261~54.2592 | 1.3565~45.216 | 600 | 50.87~12208 | 305.2~10173 |
| 50 | 0.3533~84.78 | 2.1195~70.65 | 700 | 69.24~16616 | 415.4~13847 |
| 65 | 0.5970~143.28 | 3.5819~119.39 | 800 | 90.44~21703 | 542.6~18086 |
| 80 | 0.9044~217.03 | 5.4259~180.86 | 900 | 114.46~27468 | 686.7~22890 |
| 100 | 1.413 ~339.12 | 8.478~282.6 | 1000 | 141.3~33912 | 847.8~28260 |
| 125 | 2.2079~529.87 | 13.2468~441.56 | 1200 | 203.5~48833 | 1221~40694 |
| 150 | 3.1793~763 | 19.0755~635.85 | 1400 | 277~66467 | 1662~55389 |
| 200 | 5.652~1356 | 33.912~1130.4 | 1600 | 361.8~86814 | 2171~72345 |
| 250 | 8.8313~2119 | 52.9875~1766 | 1800 | 457.9~109874 | 2747~91562 |