Mouse Bcl-2 related X protein (BAX) ELISA kit

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Product name: Mouse Bcl-2 related X protein (BAX) ELISA kit Suitable species: Mouse Application field: For scientific research experiments only, not for clinical diagnosis. Please read the instructions carefully before use Storage conditions: 2-8 ℃, shelf life of 6 months.

Product Details

Brand: ZCIBIO (ZCIBIO)

Product Name:Mouse Bcl-2 related X protein (BAX) ELISA kit

Application fields:Mouse Bcl-2 related X protein (BAX) ELISA kitFor scientific research experiments only, not for clinical diagnosis. Please read the instructions carefully before use

(If you need to know the product manual, please contact our customer service. We will provide you with service. The product is only for scientific research experiments and cannot be used in clinical practice. Thank you.)



Detection Principle Coat the target antibody in a 96 well microplate to form a solid phase carrier. Add standard or specimen to each well, and the target is bound to the antibody on the solid phase carrier. Then add the microbial target antibody, wash the unbound antibody, add HRP label and avidin, wash again, and add TMB substrate for color development. TMB is converted to blue under the catalysis of peroxidase and to the final yellow under the action of acid. The depth of color is positively correlated with the target in the sample. Measure the absorbance (O.D. value) at a wavelength of 450nm using an enzyme-linked immunosorbent assay (ELISA) reader and calculate the sample concentration.
reaction type ELISA
specification 96T/48T
reaction time 2.5 h
reactivity mouse
detection method Double antibody sandwich method
Testing Scope 0.25 ng/mL – 8 ng/mL
sensitivity 0.1 ng/mL
Sample volume 50 μ L/well
Sample Type Serum, plasma, tissue, cell supernatant or other biological samples
Precautions for pipetting
The key to repeated and accurate pipetting is consistent operation. Smooth and rapid pipetting operation is very important. Avoid vigorous movement when absorbing and releasing liquids.

Check if the size of the gun head is appropriate and if it is securely fixed.

◆ When adding samples or reagents dropwise, change the nozzle each time.

Do not transfer liquids smaller than the minimum volume recommended by the pipette manufacturer. Otherwise, it will reduce the accuracy and reproducibility of the experiment.

Some liquids are prone to adhere to the inner and outer surfaces of the gun head, so it is best to wash the gun head in advance to avoid volume changes caused by surface tension. This will increase the accuracy of the transfer.

If the liquid that needs to be moved is viscous, please stay in the liquid to be taken for a period of time before removing it when the volume reaches equilibrium.

After using a pipette to extract the liquid, dry the outer surface of the gun head with a lint free paper.

If bubbles appear inside the nozzle when sucking liquid, discharge the already sucked liquid and slowly suck it again from the container. If bubbles still appear inside the gun head, replace the gun head.

◆ If foam appears in the gun head when sucking liquid, slightly tilt the pipette and slowly suck the liquid.

Each reagent is prepared and stored separately