■ Temperature measurement of coil winding
■ Temperature measurement of stator core
Electric motor
■ Engine
Industries such as pharmaceuticals, food, electricity, metallurgy, glass, chemicals, rubber, and textiles
| insulation resistance | When the ambient temperature is within the range of (15-35) ℃ |
| When the relative humidity is less than 80% | |
| The insulation resistance value of platinum resistance should be greater than 100M Ω | |
| Self heating effect | Thermal resistance allows a maximum measured current of 2-5mA |
| The resulting temperature rise shall not exceed 0.3 ℃ | |
| insulation class | H-grade |
| Protection level | IP65 |
| probe length | 60mm,80mm,100mm,200mm,250mm,500mm |
| Probe width | 8mm,10mm,12mm |
| Probe thickness | 3mm |
| Voltage endurance range | 2.5KV,4KV |
| response time | t0.5,10s~120s |
| accuracy class | Pt100, Class A: ± (0.15+0.002 | t |) |
| Grade B: ± (0.30+0.005 | t |) | |
| | t | "is the absolute value of the measured temperature of the temperature sensing element | |
| Connecting wires | Silicone, ambient temperature -50~180 ℃, polytetrafluoroethylene |
| Silicone, ambient temperature -50~180 ℃, polytetrafluoroethylene | |
| Electrical connection | The end of the wire is exposed and can be equipped with a cold press connector or a multi pin connector |
| wiring method | Two wire system, three wire system |
·The standard for cable connection ends is to directly expose the outgoing line. If you need a cold pressed joint or socket, please consult our sales personnel and indicate it when selecting;
·The standard cable material is silicone cable. For other materials, please consult our sales staff and specify when selecting;
·For special ranges or the selection of other temperature sensing components, please consult our sales personnel and specify when selecting;
·The standard isolation voltage of PL7110 is 2.5KV. If you need to choose a 4KV withstand voltage strength, please consult our sales personnel and indicate it when selecting.