Product Parameters Brand: Model: Weight: Measurement Range:
Mineral rockBulk density tester

Applicable to:Mineral mining industry, geological research laboratory
According to the criteria; According to ASTM C39, ASTM C128, ASTM C127, AASHTOT 84, JIS, GB/T23561 specifications. Adopting Archimedes' principle and buoyancy method, applying vacuum saturation method, boiling saturation method, particle immersion method to quickly read measurement values.
Three density measurement modes:
Mode 1: For non absorbent materials, density and volume can be directly read;
Mode 2: Directly read bulk density, wet density, apparent density, apparent porosity, water absorption, open pore volume, sealed pore volume, and total porosity
Mode 3: The wax sealing method can directly read the bulk density and volume.
Mode 4: The water absorption rate of the absorbent material can be directly read.
Specification: (The following three methods can be used to measure product density using silicone oil method. If mercury method is required, please contact the supplier)
|
Model:
|
FK-300Z
|
FK-600Z
|
FK-120Z
|
|
Weighing range:
|
0.005g~ 300g
|
0.005g~ 600g
|
0.001g~ 120g
|
|
Specific gravity accuracy:
|
0.001 g/cm3
|
0.0001 g/cm3
|
|
Measurement time:
|
About 10 seconds
|
|
Setting function:
|
Temperature compensation setting, solution compensation setting, sealing wax density setting, saturated medium (oil) density setting
|
|
Measurement function:
|
Bulk density, wet density, apparent porosity, water absorption, open pore volume, closed pore volume, total porosity
|
This machine adopts an integrated injection molding measuring frame and an integrated injection molding transparent water tank, which is easy to assemble, wear-resistant, drop resistant, corrosion-resistant, and can clearly observe the condition of the sample in the medium.
Standard attachments:
① Host, ② sink, ③ measuring table, ④ tweezers, ⑤ instruction manual, ⑥ weights, ⑦ windproof and dustproof cover, ⑧ one set of particle measuring accessories, ⑨ one set of float measuring accessories, ⑩ one power transformer
Functional characteristics and devices:
·Gold plated ceramic capacitive sensor;
·Electronic balance combined with density testing device can achieve density testing of liquids and solids;
·Can be used in conjunction with a constant temperature water bath to measure the specific gravity of liquids at the required temperature;
·Density direct reading reduces tedious calculations;
·Standard RS232 data output function, easy to connect to PC and printer.;
·Fully automatic zero point tracking, buzzer alarm, overload alarm function
·External dimensions, 270 * 270 * 270; Weight; 6.5KG
·Integrated sink size, 165 * 115 * 85
·Blue backlit LCD display;
The measurement steps of saturation method density:
① Place the sample on the measuring table, measure the weight in the air, and press the M key to memorize.
② After saturating the sample, place it on the measuring table, measure the weight in the air, and press the M key to memorize.
③ After saturating the sample, place it in water, measure the weight in the water, press the M key to memorize, and directly display the density value.
Press 0 to switch between displaying wet density, apparent porosity, water absorption, open pore volume, closed pore volume, and total porosity.
Measurement steps for density of non absorbent materials:
① Place the sample on the measuring table, measure the weight in the air, and press the M key to memorize.
② Immerse the sample completely in water, measure the weight in water, press the M key to memorize, and directly display the density value.
Measurement steps for density of porous materials using wax sealing method:
① Place the sample on the measuring table, measure the weight in the air, and press the M key to memorize.
② Place the sample in the wax oven and seal it with wax before placing it on the measuring table. Measure the weight in the air and press the M key to memorize.
③ Put the sealed wax sample into water, measure the weight in the water, press the M key to remember, and directly display the density value. Press 0 to switch the display volume.