Overview

The fully automatic coal mine gas chromatograph GC-4085 (configuration type II) is the core component of the coal mine bundle tube automatic monitoring system Z. GC-4085 (configuration type II) coal mine chromatograph is a national scientific and technological research project. It has the structural characteristics of dual column box temperature control, parallel injection of three columns, and exchange of chromatographic columns and multiple detectors. It can automatically connect the sampler with 12-32 gas sampling tubes underground, and realize automatic sampling, pre cutting, detection, gas content exceeding automatic alarm and report printing through microcomputer control and data processing workstation.

Product Details

Mine gas chromatographProduct Introduction

1. Fully automated operation: The instrument is automatically controlled by a microcomputer, achieving uninterrupted cyclic sampling from 1 to 32 points (expandable to more than 32 points), automatic injection and analysis of three columns simultaneously, automatic printing of analysis reports, and data transmission through the network.
2. High stability: Dual hydrogen flame, thermal conductivity detector, dual column box, three column parallel connection, equivalent to the configuration of two gas chromatographs combined into one. The dual column box device ensures the analysis of 10 gas components such as carbon monoxide, alkenes, and alkanes at different temperatures in different column boxes, ensuring the separation degree of each analytical component, greatly improving the analysis speed and accuracy, and ensuring the reliability of prediction and forecasting.
3. Safety and longevity: Three pre column devices prevent contamination of the three analytical columns, ensuring long-term uninterrupted operation of the entire instrument.
4. Rapid analysis: The instrument is equipped with a special blowback device, which greatly shortens the time of each analysis cycle. Complete the analysis of constant O2, N2, Co, Co2 and trace amounts of Co, CH4, C2H2, C2H4, C2H6 within 4-8 minutes with a single injection, providing data for rapid fire detection. Complete the analysis of constant O2, N2, CH4 and trace amounts of Co, Co2, CH4, C2H2, C2H4, C3H8 within 10 minutes.
5. Coexistence of routine analysis and patrol monitoring: For certain special locations (without sampling points), routine methods can also be used to collect gas samples back to the laboratory using a bladder and complete routine analysis.
6. Automatic/manual conversion function: With this function, it is easy to achieve automatic monitoring of the beam tube and efficient conversion of the universal laboratory gas chromatograph.
7. Multifunctional: It can also achieve testing and analysis of the components of mine gas, tracer sulfur hexafluoride, sulfur dioxide, and other components.
8. The minimum detection concentration of gas components that mainly indicate the natural combustion process of coal seams:
Whole component: CO ≤ 0.5ppm
C2H4≤0.1ppm
C2H2≤0.5ppm
CO2 ≤2.00ppm
C2H6、C3H8≤0.5ppm
CH4 ≤0.1ppm
System error ≤ 1.0%

Mine gas chromatographProduct Features:


1. The A5085E system analysis software is a supporting data processing software and explosion triangle software for the GC-4085 (configuration type II) detection system. Can run on systems such as Win98, Win2000, WinXP, Vista, Win7, etc
2. 24 bit high-precision data acquisition module improves data accuracy
3. Feedback control function with temperature and valve

The main functions and technical parameters of are as follows:


1. Self ignition fire prediction function: By measuring the natural ignition marker gas, olefin to alkane ratio, and chain to alkane ratio, the temperature changes of the fire source can be predicted in a timely and accurate manner.
2. Control the four channel 24 bit A/D converter and reserve one channel for backup (domestic * four channel data processing).
3. Automatic alarm for gas content exceeding the limit.
4. Analyze data, spectra, and automatically store and print parameters.
5. It has networking function to achieve data sharing for analysis.
6. Single point correction, curve correction, and multiple curve fitting methods.
7. Peak recognition and processing capability *, high sampling accuracy, capable of handling small peaks, trailing peaks, and solvent peaks with ease.
8. Easy to operate, good repeatability, providing multiple sampling control and post-processing methods, and improving work efficiency.
10. Sampling frequency: 20 times/S, 30 times/S, 60 times/S.
11. Sampling sensitivity: 0.1mv/s
12. Range: ± 1V
13. Peak detection method: peak height, peak area.
14. The explosion triangle software can determine the degree of danger of the tested gas explosion based on the analysis results