- Phone
-
Address
Shop 107, No.4, Lanyue Capital
Taizhou Haihuan Instrument Equipment Co., Ltd
Shop 107, No.4, Lanyue Capital
The microcoulometric chlorine analyzer is based on the national standard GB/T18612-2011. According to the microcoulometric principle, all forms of chlorine in the sample are converted into HCl at high temperatures in nitrogen and oxygen, and enter the titration cell. In the cell, silver ions are produced through electrolysis and react with chloride ions. The microcomputer automatically calculates the total chlorine content in the sample based on the electricity consumed by the silver ions and Faraday's law. The entire analysis process is controlled by a computer, and the samples are loaded by an automatic sampler, with a high degree of instrument automation. It can be used for the analysis of trace chlorine in petrochemical products and is widely used in industries such as petroleum, chemical, scientific research, teaching, environmental protection, quality inspection, and commercial inspection.
Microcoulometric quartz tubetechnical indicators:
● Bias voltage range:0 ~500mv
● Sample variety: Liquids, gases, and solids
● measurement range: Cl:0.2 ~5000 mg/L (Concentration exceeds5000mg/LDilutable analysis)
● Temperature control range: Room temperature~1000℃ Temperature control accuracy: ±1℃
● measurement accuracy:
Sample concentration (ng)/Ml) |
Injection volume(Ml) |
RSD(%) |
0 ~0.5 |
10 |
35 |
1.0 |
10 |
10 |
100 |
8 |
3 |
1000 |
8 |
2 |
● Gas source requiredseek: Universal nitrogen, universal oxygen
● Power requirements:AC 220V±22V,50HZ±0.5HZ
● PowerHost 125W, Heating 3500W
Microcoulometric quartz tubeMain characteristics of the instrument:
● Fully configured, widely applicable, automatically converted into corresponding parameters based on form and density, with good performance and high degree of automation.
● Computer control, display the entire process status, illustrate the parameters of the entire titration process, and save data for easy retrieval and printing of various results.
The furnace body and main unit are equipped with shielding devices to eliminate the risk of furnace temperature runaway and also solve the interference with the titration cell baseline during the heating process.
● Simple operation, reliable performance, good stability, and easy installation. The cracking system is air-cooled and the fan automatically starts and stops.
Instrument execution standards:
ASTM D5808-18Test method for detecting organic chlorine in aromatic hydrocarbons and related compounds using microcoulometry
ASTM D5808-09aStandard Test Method for Chlorine in Aromatic Hydrocarbons and Related Chemicals by Microcoulometric Analysis
ASTM D5194-96Test method for trace chloride in liquid aromatic hydrocarbons
SH/T 1757-2006Determination of Organic Chlorine in Industrial Aromatic Hydrocarbons by Microcoulometric Method
GB/T 18612-2011|Determination of Organic Chlorine Content in Crude Oil
ASTM D4929-2017Test Method for Determining Organic Chlorine Content in Crude Oil
GB/T 23971-2009Appendix B Determination of Total Chlorine Content in Crude Oil by Coulometric Method
SH/T 0677- 1999Appendix A Total Chlorine Content in Crude Oil and Determination Method (Electricity Method)
UOP779-08 Chloride in Petroleum Distillates by Microcoulometry
YB/T 5022-2016Crude benzene sulfur chlorine detection