Welcome Customer !

Membership

Help

Jinan West Machinery Equipment Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products
Product Categories

Jinan West Machinery Equipment Co., Ltd

  • E-mail

  • Phone

    13706412743

  • Address

    No. 11, Machine Tool Second Factory Road, Huaiyin District, Jinan City

Contact Now

Microcomputer controlled spring tension compression integrated machine TLS-W (20~200)

NegotiableUpdate on 11/24
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The microcomputer controlled spring tension compression integrated machine is made according to the technical requirements specified in JB/T7796-2005 "Technical Conditions for Tension Compression Spring Testing Machines". This type of tension compression spring testing machine is mainly used to test the strength of various spiral springs and elastic components, that is, to test the test force of the spring under a certain deformation (or height) or to measure the height or deformation of the spring under a certain test force.

Product Details

Main purpose and scope of application:
The microcomputer controlled spring tension compression integrated machine is made according to the technical requirements specified in JB/T7796-2005 "Technical Conditions for Tension Compression Spring Testing Machines". This type of tension compression spring testing machine is mainly used to test the strength of various spiral springs and elastic components, that is, to test the test force of the spring under a certain deformation (or height) or to measure the height or deformation of the spring under a certain test force.
The machine adopts a structural design that integrates the body and computer into one unit, which facilitates the operation of computer software control and spring testing steps by the staff. Moreover, the appearance is novel, beautiful and generous.

Main specifications, technical parameters, and technical indicators:

serial number Project Name Specification parameters and indicators
1 Maximum test force (N) 20 50 100 200
2 Display Range (N) 0~20 0~50 0~100 0~200
3 Accurate measurement range of experimental force 0.4%~100% of full range
4 Minimum displacement reading value 0.001mm
5 Maximum stroke for tensile and compression tests 200mm
6 Pressure plate diameter Φ50mm
7 Parallelism of the upper and lower pressure plates ≤0.1mm
8 Force accuracy ± 0.5% (indicated value)
9 Deformation indication error ≥±(50+0.15λ)cm
Note: λ is the distance between the pressure plates measured at any position (mm) (actual error range controlled within 0.05mm)

10 Overall dimensions 400*500*600
11 weight 80kg