Welcome Customer !

Membership

Help

Chengdu Hengtong Xingye Technology Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products
Product Categories

Chengdu Hengtong Xingye Technology Co., Ltd

  • E-mail

  • Phone

  • Address

    No. 1208, 12th Floor, Unit 1, Building 1, No. 47 Donghua 1st Road, Chenghua District, Chengdu City, Sichuan Province

Contact Now

Microcomputer based total hardness waterproof photometric tester

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Compliant with IP67 waterproof standards, featuring innovative optical system design, with precision, repeatability, and measurement time required, meticulously designed CAL Check The function allows for performance validation and calibration of instruments using NIST traceable standards, with multiple measurement methods available. Users can choose to use powder or water reagents, and a built-in reaction timer ensures consistency between sample measurements and user results. It automatically records 50 measurement readings, displays the date and time of the last user calibration using Good Laboratory Practice (GLP), has a battery status indicator light, and an automatic shutdown setting

Product Details

Product Introduction
Measurement range: LR: 0 to 250 mg/L (ppm) CaCO3;
MR:200 to 500 mg/L(ppm)CaCO3;
HR:400 to 750 mg/L(ppm)CaCO3
Reminder: Press [Methods] to enter the unit selection, and use the [▼▲] keys to convert the total hardness [CaCO3] reading into a normal G degree [º F] reading, an English G degree [º E] reading, or a German G degree [º dH] reading, meeting your needs for different measurement unit results.
Compliant with IP67 waterproof standards, featuring innovative optical system design, precision, repeatability, and measurement time required, meticulously designed CAL Check ™ The function allows for performance validation and calibration of instruments using NIST traceable standards, with multiple measurement methods available. Users can choose to use powder or water reagents, and a built-in reaction timer ensures consistency between sample measurements and user results. It automatically records 50 measurement readings, displays the date and time of the last user calibration using Good Laboratory Practice (GLP), has a battery status indicator light, and an automatic shutdown setting
Product Features
High quality LED light source system
Compared with traditional tungsten lamps and other light sources, LED light sources have higher performance and luminous efficiency, and can provide the best and stable light source with less energy. LEDs can ignore the heat generated by themselves, as higher heat can affect the stability of electronic products.
High quality optical filter
8 nm narrowband interference filter, accurate to ± 1 nm, with a 25% increase in absorbance. The improved optical filter ensures higher wavelength accuracy and allows for brighter, stronger signals to be received, higher measurement stability, and less wavelength error, ensuring measurement accuracy and precision.
Reference detector
The internal reference system can compensate for any drift caused by battery voltage fluctuations or environmental temperature changes. By automatically adjusting the voltage of the LED, it achieves consistent and stable light source output, enabling fast and stable readings between blank (zero) measurements and sample measurements.
Stable and efficient light source setting
High quality concave focusing lenses can collect all the light transmitted through the glass cuvette, reducing errors caused by defects and scratches in the glass cuvette, and minimizing errors and reading deviations caused by defects in the glass cuvette.
CAL Check ™ function
Carefully designed CAL Check ™ Function, allowing the use of NIST traceable standards for instrument performance validation and calibration; CAL Check ™ NIST curve calibration group is used to simulate specific absorbance values for each wavelength to verify the accuracy of subsequent readings. CAL Check ™ The CAL check screen guides the user through the verification process and user calibration step by step.
Technical specifications
HI97735 total hardness
measurement range

LR【P1】:0 to 250 mg/L(ppm)CaCO3
MR【P2】:200 to 500 mg/L(ppm)CaCO3
HR【P3】:400 to 750 mg/L(ppm)CaCO3
resolution
LR:1 mg/L( ≤ 100 mg/L ); 5 mg/L ( > 100 mg/L); MR:/HR:5 mg/L
precision
@25ºC/77ºF
LR: reading ± 4% ± 5 mg/L; MR: reading ± 3% ± 7 mg/L; HR: Reading ± 2% ± 10 mg/L
standard method
Refer to EPA Recommended Method 130.1
unit conversion
By using the 【 ▼▲】 keys, convert the total hardness 【 CaCO3 】 reading to a normal G degree 【 º F 】 reading, an English G degree 【 º E 】 reading, or a German G degree 【 º dH 】 reading
optical system
Light source mode
silicon photocell, LED @ 466 nm
Filter bandwidth
8 nm ±1.0 nm
Other indicators
data management
Automatically store, query, and extract the last 50 measurement readings
Power mode
3 × 1.5AAA high-performance battery, automatically shuts down after 15 minutes of inactivity in measurement mode
Usage environment
0 to 50 ° C (32 to 122 ° F), RH max 100%, compliant with IP67 waterproof standard
Size and Weight
Host size: 142.5 x 102.5 x 50.5 mm (5.6 x 4.0 x 2.0 '), host weight: 380 g (13.4 oz.)
Exclusive attachments
Glass colorimetric dish
HI731397 glass colorimetric dish (HI731331+HI731336), specification: outer diameter 24.6mm (inner diameter 22mm), 4 sets/group
Measurement reagents
HI93735-0 Customized Full Range Total Hardness Reagent with 100 Predictions
HI93735-00 Customized Low Range [LR] Total Hardness Reagent with 100 Predictions
HI93735-01 Customized Medium Range [MR] Total Hardness Reagent with 100 Predictions
HI93735-02 customized high range [HR] total hardness reagent prediction times 100 times
Standard Curve Verification Group
HI97735-11 total hardness NIST measurement curve calibration group, standard values @ 25 º C: 0 and 150 ± 5 mg/L [LR], 350 ± 7 mg/L [MR], 520 ± 10 mg/L [HR]
Standard Configuration
HI97735
Host, dedicated total hardness reagent [HI93735-00 low range total hardness reagent or HI93735-01 medium range total hardness reagent or HI93735-02 high range total hardness reagent, choose one range reagent, indicate the required dedicated total hardness reagent model or range when ordering], HI731397 customized dedicated glass colorimetric dish (2 pieces), HI731318 dedicated glass colorimetric dish cleaning cloth (2 pieces), Chinese and English user manual, HI721097 customized dedicated instrument carrying case [Warm reminder: To verify instrument performance, please order HI97735-11 total hardness NIST measurement curve calibration group]
HI97735D
Host, HI93735-0 special total hardness reagent [0 to 750mg/L], HI731397 customized special glass colorimetric dish (2 pieces), HI731318 special glass colorimetric dish cleaning cloth (2 pieces), Chinese and English user manual, HI721097 customized special instrument carrying case [Warm reminder: To verify instrument performance, please order HI97735-11 total hardness NIST measurement curve calibration group]
HI97735C
Host, dedicated total hardness reagent [HI93735-00 low range total hardness reagent or HI93735-01 medium range total hardness reagent or HI93735-02 high range total hardness reagent, choose one of the range reagents, indicate the required dedicated total hardness reagent model or range when ordering], HI97735-11 total hardness NIST measurement curve calibration group, HI731397 customized dedicated glass colorimetric dish (2 pieces), HI731318 dedicated glass colorimetric dish cleaning cloth (2 pieces), Chinese and English user manual, HI7101412 customized dedicated instrument carrying case
HI97735DC
Host, HI93735-0 dedicated total hardness reagent [0 to 750mg/L], HI97735-11 total hardness NIST measurement curve calibration group, HI731397 customized dedicated glass colorimetric dish (2 pieces), HI731318 dedicated glass colorimetric dish cleaning cloth (2 pieces), Chinese and English user manual, HI7101412 customized dedicated instrument carrying case