Welcome Customer !

Membership

Help

Junqi Instrument Equipment (Shanghai) Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products
Product Categories

Junqi Instrument Equipment (Shanghai) Co., Ltd

  • E-mail

  • Phone

    18017027751

  • Address

    No. 293-295 Yexie Yexiao Road, Songjiang District, Shanghai

Contact Now

MicroPette manual (adjustable&fixed) pipette

NegotiableUpdate on 02/19
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Each pipette of Dalong has undergone factory testing and calibration according to the requirements of ISO8655 before leaving the factory, and the claimed inaccuracy and precision are superior to the specified standards of ISO8655. During the use of pipettes, deviations may occur due to various reasons, and regular calibration is an important means to ensure their accuracy.
Product Details

Characteristics of single channel pipette
-Lightweight and designed to conform to ergonomics
-Digital window, making the set range clear at a glance
-Wide range of measurement, from 0.1 μ l to 10ml
-Using attachment tools allows for convenient and efficient calibration and maintenance
-Accurate liquid separation, each pipette is calibrated according to EN/ISO8655 standards
-The lower half can be sterilized under high temperature and high pressure
-Adopting new materials

The multi-channel pipette also has the following innovative features
-The nozzle ejector can simultaneously eject multiple suction nozzles, which is efficient and labor-saving
-8 and 12 pipettes of various ranges are suitable for standard 96 well plates
-The liquid head can rotate 360 degrees, making it convenient for pipetting
-Each nozzle connection has an independent piston device, making maintenance and repair convenient
-Special nozzle connector design, easy to observe the sealing condition of the suction nozzle

calibration
Each pipette of Dalong has undergone factory testing and calibration according to the requirements of ISO8655 before leaving the factory, and the claimed inaccuracy and precision are superior to the specified standards of ISO8655.
During the use of pipettes, deviations may occur due to various reasons, and regular calibration is an important means to ensure their accuracy.

Da LonginstrumentWe provide free online calibration support through our website. If you need calibration, please log in to www.dragon-lab.com. With our online calibration software, you can perform simple, accurate, and timely calibration work without any cost, and avoid calibration errors caused by non professional operations.

We have listed the necessary conditions and standard procedures for calibration in the calibration guide. Please follow the steps to ensure the accurate implementation of calibration. At the same time, there are also properly calibrated video materials available for reference in the "Online Classroom" section of the Dalong website.


Ordering Information

MicroPette Single channel manually adjustable pipette
Item Number range increment Measuring Volumeμl Allow * system error
Inaccuracy
Allow * random error
inaccuracy
% μl % μl
71211010000 0.1-2.5μl 0.05μl 2.5 2.50% 0.0625 2% 0.05
1.25 3% 0.0375 3% 0.0375
0.25 12% 0.03 6% 0.015
71211040000 0.5-10μl 0.1μl 10 1% 0.1 0.80% 0.08
5 1.50% 0.075 1.50% 0.075
1 2.50% 0.025 1.50% 0.015
71211050000 2-20μl 0.5μl 20 0.90% 0.18 0.40% 0.08
10 1.20% 0.12 1% 0.1
2 3% 0.06 2% 0.04
71211060000 5-50μl 0.5μl 50 0.60% 0.3 0.30% 0.15
25 0.90% 0.225 0.60% 0.15
5 2% 0.1 2% 0.1
71211080000 10-100μl 1μl 100 0.80% 0.8 0.15% 0.15
50 1% 0.5 0.40% 0.2
10 3% 0.3 1.50% 0.15
71211090000 20-200μl 1μl 200 0.60% 1.2 0.15% 0.3
100 0.80% 0.8 0.30% 0.3
20 3% 0.6 1% 0.2
71211110000 50-200μl 1μl 200 0.60% 1.2 0.15% 0.3
100 0.80% 0.8 0.30% 0.3
50 1% 0.5 0.40% 0.2
71211140000 100-1000μl 5μl 1000 0.60% 6 0.20% 2
500 0.70% 3.5 0.25% 1.25
100 2% 2 0.70% 0.7
71211160000 200-1000μl 5μl 1000 0.60% 6 0.20% 2
500 0.70% 3.5 0.25% 1.25
200 0.90% 1.8 0.30% 0.6
71211170000 1000-5000μl 50μl 5000 0.50% 25 0.15% 7.5
2500 0.60% 15 0.30% 7.5
1000 0.70% 7 0.30% 3
71211330000 2-10ml 0.1ml 10ml 0.60% 60 0.20% 20
5ml 1.20% 60 0.30% 15
2ml 3% 60 0.60% 12
8Dao manual adjustable pipette
Item Number range increment Measuring Volumeμl Allow * system error
Inaccuracy
Allow * random error
inaccuracy
% μl % μl
71212040000 0.5-10μl 0.1μl 10 1.50% 0.15 1.50% 0.15
5 2.50% 0.125 2.50% 0.125
1 4% 0.04 4% 0.04
71212060000 5-50μl 0.5μl 50 1% 0.5 0.50% 0.25
25 1.50% 0.375 1% 0.25
5 3% 0.15 2% 0.1
71212120000 50-300μl 5μl 300 0.70% 2.1 0.25% 0.75
150 1% 1.5 0.50% 0.75
50 1.50% 0.75 0.80% 0.4
12Dao manual adjustable pipette
Item Number range increment Measuring Volumeμl Allow * system error
Inaccuracy
Allow * random error
inaccuracy
% μl % μl
71213040000 0.5-10μl 0.1μl 10 1.50% 0.15 1.50% 0.15
5 2.50% 0.125 2.50% 0.125
1 4% 0.04 4% 0.04
71213060000 5-50μl 0.5μl 50 1% 0.5 0.50% 0.25
25 1.50% 0.375 1% 0.25
5 3% 0.15 2% 0.1
71213120000 50-300μl 5μl 300 0.70% 2.1 0.25% 0.75
150 1% 1.5 0.50% 0.75
50 1.50% 0.75 0.80% 0.4
Manually fix the pipette
Item Number range increment Measuring Volumeμl Allow * system error
Inaccuracy
Allow * random error
inaccuracy
% μl % μl
71221180000 5μl - 5μl 1.3% 0.065 1.2% 0.06
71221190000 10μl - 10μl 0.8% 0.08 0.8% 0.08
71221200000 20μl - 20μl 0.6% 0.12 0.5% 0.1
71221210000 25μl - 25μl 0.5% 0.125 0.3% 0.075
71221220000 50μl - 50μl 0.5% 0.25 0.3% 0.15
71221230000 100μl - 100μl 0.5% 0.5 0.3% 0.3
71221240000 200μl - 200μl 0.4% 0.8 0.2% 0.4
71221250000 250μl -- 250μl 0.4% 1.0 0.2% 0.5
71221260000 500μl - 500μl 0.3% 1.5 0.2% 1.0
71221270000 1000μl - 1000μl 0.3% 3.0 0.2% 2.0
71221280000 2000μl - 2000μl 0.3% 6.0 0.15% 3.0
71221290000 5000μl - 5000μl 0.3% 15 0.15% 7.5

Updated on September 2, 2020 at 10:22:41