- Phone
-
Address
19E, Unit 4, Building C, Yingdu Building, No. 48 Zhichun Road, Haidian District, Beijing
Beijing Fulbang Technology Development Co., Ltd
19E, Unit 4, Building C, Yingdu Building, No. 48 Zhichun Road, Haidian District, Beijing
Product Introduction
FP CC-420AMicro continuous closed flash point analyzeris based onProfessional testing instrument for combustion hazard characteristics developed by continuous closed cup method.
FP CC-420AMicro continuous closed flash point analyzerSuitable for precise measurement in fields such as petroleum, petrochemicals, and chemical engineeringpetroleumProducts, transformer oil, turbine oilpaint、spiceThe木材防腐油、Aromatic oil、Animal and vegetable oils、pesticide emulsifierHigh viscosity materialsplasticizerThe closed flash point of a substance.
Testing Standards
SH/T 0768,SN/T 3077.1,DL/T 1354,ASTM D6450
SN/T 3077.2,ASTM D7094
GB/T 261,GB/T 21615,ASTM D93
GB/T 5208,GB/T 21790,ASTM D3828
Product Features
1)Adopting the continuous closed cup flash point testing method, it is more accurate and efficient
2)Small sample size, low testing cost, and minimal pollution
3)Continuous closed cup operation, no open flame, high safety
4)Built in refrigeration module, wide flash point testing range, cooling effectfast speed
5)Pre set standard testing methods and can be associated with other closed cup methods
6)Fully automated detection, automatic atmospheric pressure correction flash point
7)Real time display of temperature and pressure curves, making the testing process more intuitive
8)The test results include temperature-Pressure rise curve provides more information on flash ignition
9)User level management, which can achieve account management and control at different levels
10)USB interface plug and play, optional thermal printer for convenient data management
11)7-inch color touch screen, supports Chinese input, intuitive and simple operation
Technical Specifications
working environment |
5℃~40℃,<85%RH |
temperature range |
0℃~260℃ -30℃~260℃(Equipped with low-temperature module) 0℃~420℃ (Equipped with high-temperature module) -30℃~420℃(Equipped with low-temperature and high-temperature modules) |
heating rate |
2.5±0.3℃/min,5.5±0.5℃/min, 0.5~12℃/minCustomization |
Temperature detection accuracy |
±0.1℃ |
Pressure detection range |
0 kPa~200 kPa |
sample size |
1mLor2mL |
ignition method |
High voltage electronic ignition |
stirring speed |
50rpm~300rpmSoftware can be configured |
storage space |
5000A test result |
interface |
RS232*1,RJ45*1,USB*2 |
Power supply |
AC220V/50Hz |
power |
300W |
size |
225mm*310mm*415mm |
weight |
13.5kg |