- Phone
-
Address
3rd Floor, Building B, U Valley Science and Technology Innovation Center, Xingmao 1st Street, Tongzhou District, Beijing
Beijing Box Biotechnology Co., Ltd
3rd Floor, Building B, U Valley Science and Technology Innovation Center, Xingmao 1st Street, Tongzhou District, Beijing
Boxbio®Water Sample Mercury Ion Content Assay Kit
Mercury ion concentration detection kit for water samples
Heavy metal mercury in waterHas strong toxicity and high bioaccumulation, is easily absorbed and accumulated by organisms, and ultimately released through the food chainEntering the human body, it poses a serious threat to human health and the ecological environment. The determination of its content is of great significance for the evaluation and remediation of heavy metal pollution in water.
After digestion, the mercury in the water sample is mainly Hg2+Ionic forms exist, Hg2+Can react with dithizone to form an orange complex, with the product at 490nmThere is a characteristic absorption peak at this point, and the content of mercury ions in water can be quantitatively detected by changing the absorbance value.

Mercury ion concentration detection kit for water samplesInstruments and reagents required during the measurement process:Visible spectrophotometer/Enzyme linked immunosorbent assay (ELISA) reader, micro glass colorimetric dish (optical path 10 mm))/96Orifice plate, adjustable pipette, desktop centrifuge, 30-50Mesh screening, constant temperature water bath/Incubator, chloroform, concentrated sulfuric acid, concentrated nitric acid, and distilled water.
sample processing
After water sample collection, 7 mL should be added immediately per liter of samplePreparation of concentrated nitric acid ratio, thorough mixing and adjustment of each sampleThe sample to be tested is when the pH is ≤ 1.0; If the sample cannot be measured immediately after sampling, 4 mL of reagent 2 (or>4 mL) should be added to each liter of sample to make the test sample appear a persistent light red color.
Precautions during the measurement process
① During the measurement process, protective measures should be taken to avoid inhaling or coming into contact with toxic and dangerous reagents;
②If the measured absorbance value is greater than 0.6It is recommended to reduce the sample size appropriately before conducting the measurement, and make corresponding modifications when calculating;
③After adding reagent 2, the measuring tube should appear pink or purple black. If the upper solution of the measuring tube becomes transparent during digestion, the amount of reagent 2 added can be appropriately increased to keep the measuring tube pink or purple black;
④After adding reagent three, if it is not possible to make the measuring tube clear, the amount of reagent three added can be appropriately increased to make the measuring tube clear;
⑤After adding reagent six, if the lower organic phase still shows a clear green color, the amount of reagent six added can be appropriately increased to change the color of the lower organic phase to no green or light green;
⑥To ensure accurate results and avoid reagent loss, please carefully read the instructions before testing (based on the actual received instructions), confirm whether the reagent storage and preparation are sufficient, whether the operating steps are clear, and be sure to take 2-3For samples with significant expected differences, please contact the staff promptly if there are any issues during the pre testing process.
Pre purchase notice:
A. Determine the type, specifications, and quantity of reagent kits based on the indicators to be tested;
B. Confirm whether the testing equipment and conditions match;
C. Confirm whether the delivery time and receipt time meet the requirements;
★Please contact Boxbio customer service or sales specialist promptly for any questions before purchasing
Notice of Receipt:
A. Please ensure that the phone is open so that users can track the delivery status and complete the receipt based on the tracking number;
B. Please carefully inspect the item number, packaging, quantity, and appearance of the goods upon receipt (for any damage, leakage, contamination, etc.). If there are any issues with the product delivery, please contact Boxbio within 15 days;
C. After receiving the goods, please store them separately according to the temperature indicated on the product label, and use and dispose of the relevant waste correctly according to the conditions described in the instructions;
D. For product quality issues, please provide a written explanation and detailed test results for reference within 3 months from the date of receipt of the product. If you do not raise any objections to the product quality within the above period, it will be deemed that you acknowledge the product as qualified;
E. The expiration date of the BOXBIO reagent kit is 3-6 months. If the product is used unopened after the expiration date, we can exchange the product for you free of charge;
F. The express delivery costs incurred for returns and exchanges due to product quality issues will be borne by our company.
Product Customization
Boxbio provides customized services for large packaging products:
Regarding the price:The salesperson will communicate with you, inquire about the customized reagent kit you need, and negotiate the required specifications based on the sample size to be tested, and then provide you with a quotation.
Regarding packaging:Production and warehouse delivery will match the corresponding packaging according to the specifications of the reagent kit you have customized. As it is a customized product, the packaging provided may not be of regular specifications. Please be aware.
Regarding delivery time:The delivery time for customized products will be calculated based on the type and specifications of the reagent kit you have customized, and will be communicated to you by sales personnel.
Research Assistance Fund
Boxbio is committed to making scientific research easier. In order to encourage and support academic research by researchers, we have launched the "Research Assistance Fund" reward program! Any SCI article published that indicates that the product is provided by Beijing Boxbio Science&Technology Co., Ltd. can apply for the corresponding research assistance fund!
According to the journal impact factor, the reward rules are as follows:
⑴Journal impact factor: 0<IF<5, research assistance fund amount is 300 yuan;
⑵Journal impact factor: 5 ≤ IF < 10, research assistance fund amount is 800 yuan;
⑶Journal impact factor: 10 ≤ IF < 15, research assistance fund amount is 1500 yuan;
⑷Journal impact factor: 15 ≤ IF < 20, research assistance fund amount is 2500 yuan;
⑸Journal impact factor: 20 ≤ IF, research assistance fund amount is 3500 yuan.
*Non SCI articles can apply for a beautiful gift and receive corresponding points.
Application Instructions:
⑴The article must clearly indicate that the corresponding product is sourced from Beijing Box Biotechnology Co., Ltd. or Beijing Boxbio Science & Technology Co.,Ltd.;
⑵The reward is only available to the first author of the article, and co authors can only apply for one reward;
⑶The same article can only apply for research funding once;
⑷If the products cited in the literature are trial equipment, they will not participate in this activity;
⑸The interpretation rights of this event belong to Beijing Box Biotechnology Co., Ltd.
Join us
Boxbio, A young and vibrant biotechnology company, adhering to the core concept of "Make Science EASY" and the values of "customer first, scientific rigor, pursuit of innovation, optimism and positivity, communication and collaboration, and confidence", is recruiting talents for society. If you agree with the core concept of the box and are willing to contribute your own strength to it, please join us. Box Biology will definitely provide you with a broad development platform and share with you the fruitful results in realizing this concept!
May we grow together hand in hand, Box Biology looks forward to your joining!