| Item Number | Product Name | Specifications | packaging | Remarks |
| 1.19851.0001 | Solid phase extraction device 12 positions |
|||
| 1.19128.0001 | Lichrolut ® Florisil(150-250um) |
500mg/6ml | 30 pieces/pack | Suitable for organic metal compounds, organic insecticides, etc. in food and the environment |
| 1.19127.0001 | Lichrolut ® Florisil(150-250um) |
1g/6mL | 30 pieces/pack | |
| 1.19698.0001 | Lichrolut ® CN (40-63um) cyanide column |
200mg/3mL | 50 pieces/pack | Reverse phase, cyano group |
| 1.19699.0001 | Lichrolut ® CN (40-63um) cyanide column |
500mg/3mL | 50 pieces/pack | |
| 1.19870.0001 | Lichrolut ® EN(40-120um) |
200mg/3mL | 30 pieces/pack | Suitable for insecticides, phenols, explosives, aniline, polycyclic aromatic hydrocarbons, polychlorinated biphenyls, aromatic amines, chlorinated phenols in water |
| 1.19691.0001 | Lichrolut ® EN(40-63um) |
500mg/6ml | 30 pieces/pack | |
| 1.02021.0001 | Lichrolut ® Si (40-63um) silicone small column |
200mg/3mL | 50 pieces/pack | Positive phase, silica gel polarity extraction |
| 1.02024.0001 | Lichrolut ® Si (40-63um) silicone small column |
500mg/3mL | 50 pieces/pack | |
| 1.19696.0001 | Lichrolut ® NH2(40-63um) |
200mg/3mL | 50 pieces/pack | Biphasic, amino column |
| 1.02014.0001 | Lichrolut ® RP-18(40-63um) |
200mg/3mL | 50 pieces/pack | Reverse phase, C18 non-polar extraction |
| 1.02023.0001 | Lichrolut ® RP-18(40-63um) |
500mg/3mL | 50 pieces/pack | |
| 1.19687.0001 | Lichrolut ® RP-18(40-63um) |
500mg/6ml | 30 pieces/pack | |
| 1.19847.0001 | Lichrolut®RP-18endcapped(40-63um) |
200mg/3mL | 50 pieces/pack | Reverse phase, C18, End capped non-polar extraction |
| 1.19849.0001 | Lichrolut®RP-18endcapped(40-63um) |
500mg/3mL | 50 pieces/pack | |
| 1.02016.0001 | Lichrolut ® SCX(40-63um) Strong cationic column |
200mg/3mL | 50 pieces/pack | 1. Extraction of Effective Substances from Highly Polluted Basic Bodies such as Urine Samples and Plasma 2. Food insecticide sample testing 3. Basic analysis of amine substances ● Drug metabolism research Organic pollutants in drinking water or wastewater ● Detection of pesticide residues in animal or plant products ● Testing of active ingredients in food and cosmetics |
| 1.02022.0001 | Lichrolut ® SCX(40-63um) Strong cationic column |
500mg/3mL | 50 pieces/pack | |
| 1.02018.0001 | Lichrolut ® SAX(40-63um) Strong anion column |
200mg/3mL | 50 pieces/pack | Strong anion exchange |
| 1.19767.0001 | Lichrolut ® TSC(40-63um) |
300mg/3mL | 50 pieces/pack | Suitable for positively charged and neutral compounds |