-
E-mail
xmyimai@163.com
-
Phone
18050037020
-
Address
Room 1401, No. 198, Building 7, Jiaxin Garden, Dongfu New City, Haicang District, Xiamen City
Xiamen Yimai Environmental Protection Technology Co., Ltd
xmyimai@163.com
18050037020
Room 1401, No. 198, Building 7, Jiaxin Garden, Dongfu New City, Haicang District, Xiamen City
Volumetric method single component titrant, titration degree~5 mg/mL, one-component reagent for volumetric Karl Fischer titration 1 ml ≙ ca. 5 mg H ₂O Aquastar®
100
Aquastar®
liquid
reaction type: volumetric
5 mg/mL
Karl-Fischer titration: suitable
titration: suitable
1.19 g/cm3at 20 °C
single component solution
15-25°C
The concentration (efficiency) of Karl Fischer titration agent decreases over time. Therefore, potency, as a correction factor to counteract this effect as well as changes in equipment, personal operations, and laboratory conditions, must be measured immediately after opening a new bottle and should be verified regularly.
Coulomb method: applicable to samples with moisture content<1%
Brand: GermanyMERCK
Origin: Germany
Usage: Both diaphragm reaction tanks and non diaphragm reaction tanks are available
Advantages:
1The anode and cathode only need to1Bottle reagents;
2Very high precision and reproducibility;
3The equilibrium time of the reaction tank is short;
4Does not contain chlorinated hydrocarbons.
Karl Fischer titration method19century30Since its discovery, due to its wide range of moisture detection, it can be applied to various material samples such as food, chemicals, pharmaceuticals, cosmetics, and mineral oils, and has therefore been widely used worldwide. The Karl Fischer titration method is based on a chemical reaction with water to detect water content, and can accurately determine water.
At present, the Karl Fischer titration method has been included in the pharmacopoeias of various countriesSOPs(Standard Operating Procedure)ISO9000ffTheASTM(American Society for Testing and Materials) andDINListed as a standard guidance method by the German Institute for Standardization. The Karl Fischer titration method is fast, accurate, and stable, and is not affected by sample type, aggregation state, or the presence of volatile substances.
Karl Fischer titration reagent: widely applicable and can be used for water content0.1-100%The product.
Application instruments:
(1)Swiss Wantong:758 KFD TitrinoMulti purpose volumetric moisture analyzer795 KFD TitrinoExtended capacity moisture analyzer787 KF TitrinoSpecialized volumetric moisture analyzer
(2)Mettler:DL31Karl Fischer apparatusDL38Karl Fischer apparatus
Karl Fischer Coulomb reagent: high titration accuracy, versatileYuMoisture content<1%product
Application instruments:
(1)Swiss Wantong:756 KF CoulometerExtended Coulombic Karl Fischer Moisture Analyzer831KF CoulometerPractical Coulombic Karl Fischer Moisture Analyzer
(2)Mettler:DL32Karl Coulomb apparatusDL39Karl Coulomb apparatus
|
Order N.O Order Number |
PACK packaging |
Product Name |
Product Name |
1.88005.0500 |
500ML |
apura-CombiTitrant 5 , 1ml--5mg H2O |
Single component titrant 1ml-5mg H2O |
1.88005.1000 |
1L |
apura-CombiTitrant 5 , 1ml--5mg H2O |
Single component titrant 1ml-5mg H2O |
1.88002.0500 |
500ML |
apura-CombiTitrant 2 single , 1ml--2mg H2O |
Single component titrant 1ml-2mg H3O |
1.88002.1000 |
1L |
apura-CombiTitrant 2 single , 1ml--2mg H2O |
Single component titrant 1ml-2mg H3O |
1.88001.0500 |
500ML |
apura-CombiTitrant 2 single , 1ml--2mg H2O |
Single component titrant 1ml-1mg H4O |
1.88001.1000 |
1L |
apura-CombiTitrant 2 single , 1ml--2mg H2O |
Single component titrant 1ml-1mg H4O |
1.09248.1000 |
1L |
Karl Fischer reagent 5 single component reagent w |
Single component titrant 1ml-5mg H5O containing pyridine |
1.88008.1000* |
1L |
apura-CombiSolvent methanol-free |
Single component solvent, methanol free |
1.88020.1000* |
1L |
apura-Solvent for the one component titration for |
Single component solvent, oil specific |
1.88021.1000* |
1L |
apura-Solvent for the one component titration for |
Single component solvent, specifically designed for food oil |
1.88010.0500 |
500ML |
apura-Titrant 5 , 1ml--5mg H2O |
Two component titrant 1ml-5mg H2O |
1.88010.1000 |
1L |
apura-Titrant 5 , 1ml--5mg H2O |
Two component titrant 1ml-5mg H2O |
1.88011.0500 |
500ML |
apura-Titrant 2 , 1ml--2mg H2O |
Two component titrant 1ml-2mg H3O |
1.88011.1000 |
1L |
apura-Titrant 2 , 1ml--2mg H2O |
Two component titrant 1ml-2mg H3O |
1.88015.1000 |
1L |
apura-Solvent for the two component titration |
Two-component solvent |
1.88016.1000 |
1L |
apura-Solvent for the onetwo component titrati |
Two component solvent, specifically designed for oils and fats |
1.09257.0500 |
500ML |
apura-CombiCoulomat fritless for cells withw |
Coulombic reagent (non membrane specific) |
1.09255.0500 |
500ML |
Apura-CombiCoulomatfrit |
Coulombic reagent (for membrane reaction tanks) |
1.88050.0010 |
10x8ml |
apura-Water Standard 0.01% |
Standard water sample 0.1% |
1.88051.0010 |
10x8ml |
apura-Water Standard 0.1% |
Standard water sample 1% |
1.88052.0010 |
10x8ml |
apura-Water Standard 1% |
Standard water sample 1% |
1.09259.0250 |
250ml |
apura-Water standard (1 ml contains 5mg H2O) |
Standard water sample 0.06% |
1.12939.0010 |
10g |
apura-Lactose standard 5% solid standard for C/V/O |
Standard water sample 0.07% |
1.06664.0100 |
100g |
apura-Sodium tartrate dihydrate volumetric standar |
Sodium tartrate dihydrate |
1.05704.0250 |
250g |
Molecular sieve 0.3 nm beads about 2 mm LAB |
Molecular sieve 0.3nm |
Karl Fischer single component reagent |
Item Number |
use |
advantage |
|
Apura-CombiTitrant5 5Equivalent single component titrant |
1.88005.1000 |
Usage GuangUniversal reagents 1mltitration5mgH2O |
1Faster titration; 2Clear titration endpoint; 3Constant commitment and consistent high quality; 4Non toxic mixed solution, safer; 5The solvent can be prepared according to different samples. |
|
Apura-CombiTitrant2 2Equivalent single component titrant |
1.88002.1000 |
More suitable for titrating samples with lower moisture content 1mltitration2mg H2O |
|
|
Apura-CombiTitrant1 1Equivalent single component titrant |
1.88001.1000 |
Suitable for samples containing trace amounts of moisture 1mltitration1mg H2O |
|
|
Apura-CombiSolwent Single component solvent |
1.88008.1000 |
Does not contain methanol, meeting the requirements for faster and more accurate single component titration |
|
Special solvent containing methanol as a single component |
1.88009.1000 |
Moisture content not exceeding0.01% |
|
|
CombiMethanol dried (max.0.0005%H2O),SeccoSolvAnhydrous methanol (with a water content of less than0.0005%) |
1.06012.0500 |
Moisture content not exceeding0.01% |
1Faster titration; 2Does not contain harmful alcohols; 3Inhibit side reactions without precipitation; 4Mentioned accuracy and reproducibility; 5Constant commitment and consistent high quality. |
Aldehyde ketone titrant |
1.88006.1000 |
Aldehyde ketone specific type, can also be used for non aldehyde ketone products 1mltitration5mgH2O |
|
Aldehyde ketone solvent |
1.88007.1000 |
Aldehyde ketone specific solvent |