Welcome Customer !

Membership

Help

Xiamen Yimai Environmental Protection Technology Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Xiamen Yimai Environmental Protection Technology Co., Ltd

  • E-mail

    xmyimai@163.com

  • Phone

    18050037020

  • Address

    Room 1401, No. 198, Building 7, Jiaxin Garden, Dongfu New City, Haicang District, Xiamen City

Contact Now

Merck Karl Fischer Capacity Method 1.88005.1008, Germany

NegotiableUpdate on 12/30
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Merck Karl Fischer Volume Method from Germany 1.88005.1008 $r $n Item Number: 1.88005.1008 $r $n Specification: 1000ML/bottle
Product Details

Product Name

Volumetric method single component titrant, titration degree~5 mg/mL, one-component reagent for volumetric Karl Fischer titration 1 ml ≙ ca. 5 mg H ₂O Aquastar®

quality level

100

product line

Aquastar®

form

liquid

Reaction applicability

reaction type: volumetric

concentration

5 mg/mL

technology

Karl-Fischer titration: suitable
titration: suitable

density

1.19 g/cm3at 20 °C

packaging form

single component solution

Storage temperature

15-25°C

packaging

The SKU pack size number ends in "3", such as xxxxxx1003 or xxxxxxx 4003, indicating that it is a SmartChemical product. The data can be seamlessly transmitted to the instrument through the RFID tag on the product label.

analysis and explanation

The concentration (efficiency) of Karl Fischer titration agent decreases over time. Therefore, potency, as a correction factor to counteract this effect as well as changes in equipment, personal operations, and laboratory conditions, must be measured immediately after opening a new bottle and should be verified regularly.


Coulomb method: applicable to samples with moisture content<1%

Brand: GermanyMERCK
Origin: Germany
Usage: Both diaphragm reaction tanks and non diaphragm reaction tanks are available

Advantages:

1The anode and cathode only need to1Bottle reagents;

2Very high precision and reproducibility;

3The equilibrium time of the reaction tank is short;

4Does not contain chlorinated hydrocarbons.

Karl Fischer titration method19century30Since its discovery, due to its wide range of moisture detection, it can be applied to various material samples such as food, chemicals, pharmaceuticals, cosmetics, and mineral oils, and has therefore been widely used worldwide. The Karl Fischer titration method is based on a chemical reaction with water to detect water content, and can accurately determine water.

At present, the Karl Fischer titration method has been included in the pharmacopoeias of various countriesSOPs(Standard Operating Procedure)ISO9000ffTheASTM(American Society for Testing and Materials) andDINListed as a standard guidance method by the German Institute for Standardization. The Karl Fischer titration method is fast, accurate, and stable, and is not affected by sample type, aggregation state, or the presence of volatile substances.

Karl Fischer titration reagent: widely applicable and can be used for water content0.1-100%The product.

Application instruments:

1)Swiss Wantong:758 KFD TitrinoMulti purpose volumetric moisture analyzer795 KFD TitrinoExtended capacity moisture analyzer787 KF TitrinoSpecialized volumetric moisture analyzer

2)Mettler:DL31Karl Fischer apparatusDL38Karl Fischer apparatus

Karl Fischer Coulomb reagent: high titration accuracy, versatileYuMoisture content<1%product

Application instruments:

1)Swiss Wantong:756 KF CoulometerExtended Coulombic Karl Fischer Moisture Analyzer831KF CoulometerPractical Coulombic Karl Fischer Moisture Analyzer

2)Mettler:DL32Karl Coulomb apparatusDL39Karl Coulomb apparatus

Order N.O

Order Number

PACK

packaging

Product Name

Product Name

1.88005.0500

500ML

apura-CombiTitrant 5 , 1ml--5mg H2O

Single component titrant 1ml-5mg H2O

1.88005.1000

1L

apura-CombiTitrant 5 , 1ml--5mg H2O

Single component titrant 1ml-5mg H2O

1.88002.0500

500ML

apura-CombiTitrant 2 single , 1ml--2mg H2O

Single component titrant 1ml-2mg H3O

1.88002.1000

1L

apura-CombiTitrant 2 single , 1ml--2mg H2O

Single component titrant 1ml-2mg H3O

1.88001.0500

500ML

apura-CombiTitrant 2 single , 1ml--2mg H2O

Single component titrant 1ml-1mg H4O

1.88001.1000

1L

apura-CombiTitrant 2 single , 1ml--2mg H2O

Single component titrant 1ml-1mg H4O

1.09248.1000

1L

Karl Fischer reagent 5 single component reagent w

Single component titrant 1ml-5mg H5O containing pyridine

1.88008.1000*

1L

apura-CombiSolvent methanol-free

Single component solvent, methanol free

1.88020.1000*

1L

apura-Solvent for the one component titration for

Single component solvent, oil specific

1.88021.1000*

1L

apura-Solvent for the one component titration for

Single component solvent, specifically designed for food oil

1.88010.0500

500ML

apura-Titrant 5 , 1ml--5mg H2O

Two component titrant 1ml-5mg H2O

1.88010.1000

1L

apura-Titrant 5 , 1ml--5mg H2O

Two component titrant 1ml-5mg H2O

1.88011.0500

500ML

apura-Titrant 2 , 1ml--2mg H2O

Two component titrant 1ml-2mg H3O

1.88011.1000

1L

apura-Titrant 2 , 1ml--2mg H2O

Two component titrant 1ml-2mg H3O

1.88015.1000

1L

apura-Solvent for the two component titration

Two-component solvent

1.88016.1000

1L

apura-Solvent for the onetwo component titrati

Two component solvent, specifically designed for oils and fats

1.09257.0500

500ML

apura-CombiCoulomat fritless for cells withw

Coulombic reagent (non membrane specific)

1.09255.0500

500ML

Apura-CombiCoulomatfrit

Coulombic reagent (for membrane reaction tanks)

1.88050.0010

10x8ml

apura-Water Standard 0.01%

Standard water sample 0.1%

1.88051.0010

10x8ml

apura-Water Standard 0.1%

Standard water sample 1%

1.88052.0010

10x8ml

apura-Water Standard 1%

Standard water sample 1%

1.09259.0250

250ml

apura-Water standard (1 ml contains 5mg H2O)

Standard water sample 0.06%

1.12939.0010

10g

apura-Lactose standard 5% solid standard for C/V/O

Standard water sample 0.07%

1.06664.0100

100g

apura-Sodium tartrate dihydrate volumetric standar

Sodium tartrate dihydrate

1.05704.0250

250g

Molecular sieve 0.3 nm beads about 2 mm LAB

Molecular sieve 0.3nm

Karl Fischer single component reagent

Item Number

use

advantage

Apura-CombiTitrant5

5Equivalent single component titrant

1.88005.1000

Usage GuangUniversal reagents

1mltitration5mgH2O

1Faster titration;

2Clear titration endpoint;

3Constant commitment and consistent high quality;

4Non toxic mixed solution, safer;

5The solvent can be prepared according to different samples.

Apura-CombiTitrant2

2Equivalent single component titrant

1.88002.1000

More suitable for titrating samples with lower moisture content

1mltitration2mg H2O

Apura-CombiTitrant1

1Equivalent single component titrant

1.88001.1000

Suitable for samples containing trace amounts of moisture

1mltitration1mg H2O

Apura-CombiSolwent

Single component solvent

1.88008.1000

Does not contain methanol, meeting the requirements for faster and more accurate single component titration

Special solvent containing methanol as a single component

1.88009.1000

Moisture content not exceeding0.01%


CombiMethanol dried

max.0.0005%H2O),SeccoSolvAnhydrous methanol (with a water content of less than0.0005%

1.06012.0500

Moisture content not exceeding0.01%

1Faster titration;

2Does not contain harmful alcohols;

3Inhibit side reactions without precipitation;

4Mentioned accuracy and reproducibility;

5Constant commitment and consistent high quality.

Aldehyde ketone titrant

1.88006.1000

Aldehyde ketone specific type, can also be used for non aldehyde ketone products

1mltitration5mgH2O

Aldehyde ketone solvent

1.88007.1000

Aldehyde ketone specific solvent

Merck Karl Fischer Capacity Method 1.88005.1008, Germany