Measurement, verification, and calibration of gas dilution mixing and distribution devicesApplicable standard
national standard:
GB12358-2006 General Technical Requirements for Workplace Gas Detection and Alarm Devices
Verification regulations:
JJG693-2011 Combustible Gas Detection Alarm
JJG 915-2008 Carbon Monoxide Detection Alarm
JJG695-2019 Hydrogen Sulfide Gas Detector
JJG 365-2008 Electrochemical Oxygen Analyzer
JJG1105-2015 Ammonia Gas Detector
JJF1263-2010 Sulfur Hexafluoride Detection and Alarm Device
JJF1711-2018 SF6 decomposition product detector
---------------------------------------------------------------------------------------------------------------------------------------------
application field
Legal metrology verification institutions, third-party metrology calibration companies, and inspection and testing institutions (CMA) verify, calibrate, and test gas alarms
Petroleum systems, steel, gas companies, chemical and other enterprises establish measurement standards for combustible and toxic gas alarms
Gas alarm manufacturers use it for factory inspection and calibration
Calibration of sulfur hexafluoride detector for power system
---------------------------------------------------------------------------------------------------------------------------------------------
Functional characteristic parameters
■Measurement, verification, and calibration of gas dilution mixing and distribution devicesCapable of verifying portable and fixed alarm devices such as oxygen detectors, carbon monoxide detectors, combustible gas detectors, ammonia detectors, hydrogen sulfide detectors, and composite detectors in accordance with the current national metrological verification regulations.
High concentration gas standard substances such as carbon monoxide, oxygen, hydrogen sulfide, methane, ammonia, hydrogen, isobutene, etc. can be formulated into single component gas standard substances of any concentration; Multi component gas standard materials can also be configured with any one to four types of gas standard materials
Valve distribution error ± 1%
■ Gas concentration: 1 × 10-8~10-2(mol/mol)
Output flow rate (0-2000) mL/min
---------------------------------------------------------------------------------------------------------------------------------------------
after-sales service
Provide the Measurement Traceability Certificate from the China Institute of Testing Technology
Provide gas alarm measurement standard building services and measurement authorization services
Provide qualification training certificates for calibration personnel, and have relevant experts provide detailed training