- Phone
-
Address
No. 10 Yushuang Road, Chenghua District, Chengdu
Sichuan Zhongce Beige Technology Co., Ltd
No. 10 Yushuang Road, Chenghua District, Chengdu
Product Introduction
High pressure gas ratio mixing instrument - metal welding and cuttingBinary and ternary gases can be proportioned and uniformly mixed according to the required ratio, continuously and stably outputting the mixed gas, and the concentration value of the proportioning can be displayed in real time through high-precision gas concentration analysis instruments. It can be widely used in various occasions such as welding, electronic mixed gas, electric light source mixed gas, and purification and smelting of precious metals.
Selection Table
model |
Applicable gases |
Proportion concentration |
Output flow rate (Nm3/h) |
Ratio accuracy |
Input pressure (Mpa) |
|
Argon+Carbon Dioxide (Ar+CO)2) |
0-30% carbon dioxide balance, argon gas |
50~500 Customizable as needed |
±1% |
0.5~1.0 |
|
Argon+Oxygen (Ar+O)2) |
0-10% oxygen balance, argon gas |
|||
|
Argon+Nitrogen (Ar+N)2) |
0-50% argon gas with remaining nitrogen gas |
|||
|
Carbon dioxide+nitrogen (CO2+N2) |
0-50% carbon dioxide balance nitrogen |
|||
|
Argon+helium (Ar+He) |
On demand ratio |
|||
|
Argon+Hydrogen (Ar+H)2) |
0-30% argon gas with remaining hydrogen gas |
Technical Principles:
High pressure gas ratio mixing instrument - metal welding and cuttingTwo or three gases that need to be mixed are introduced into the pressure stabilization control unit for pressure balance regulation. Under equal pressure conditions, they are mixed through a mixing ratio regulating valve, and then continuously output through the flow and pressure control unit to obtain the ideal mixed gas.
Features:
Optional concentration online analyzer, users can monitor the mixing quality online and choose the appropriate option
Suitable for various gas technology applications
Adjust the mixing ratio freely through the knob
The output of mixed pressure can be adjusted as needed
The touch screen operation, display, and parameter settings have a good human-machine interface
Technical Specifications:
Universal Model |
PMC-001 |
Applicable Medium |
Ar,CO2,O2,N2,H2(or other non-toxic and corrosive gases) |
concentration range |
0-10%, 0-30%, 0-50%, 0-100% |
Quantity of mixed air |
2 yuan, 3 yuan, 4 yuan |
flow range |
50Nm3/h,100Nm3/h,200Nm3/h,400Nm3/h,500Nm3/H (customizable as needed) |
accuracy class |
±1.0% |
intake pressure |
0.5-1.0MPa |
output pressure |
0.25-0.35MPa adjustable |
Inlet/outlet diameter |
G3/4 or other specifications |
Net external dimensions |
800mm*420mm*1800mm |
Working environment temperature |
(0~50)℃ |
Power requirements |
External supply of AC220V power |
touch screen |
Colorful resistive touch screen |
Concentration online detection function |
optional |