Overview

1. Strictly sealed, with an electromagnetic clutch and a leakage rate of 183; 10-6 Pa m3/s2、 Equipped with 3-phase motor II 2G EX de IIC T43, shock resistant range up to 1600 kPa4, no thermal overload due to integrated temperature sensor 5, used for applications within ATEX (guideline 2014/34/EU), German Pfalz vacuum pump Okta 4000 ATEX maintenance

Product Details

Okta 4000 ATEX

Having a length of 2160-5190 meters3/Roots pump with suction capacity:

Product Description

  • Strictly sealed, through electromagnetic clutch, leakage rate<1.10-6Pa m3/s
  • Equipped with 3-phase motor II 2G EX de IIC T4
  • Seismic impact range up to 1600 kPa
  • No thermal overload due to integrated temperature sensor
  • For applications within the scope of ATEX (Directive 2014/34/EU)

product

  • Okta 4000 ATEX, Roots pump, 230/400 V, 50 Hz, 265/460 V, 60 Hz; II 3G IIB T3 +5℃ = Ta= +40℃ (PP W73 300)
  • Okta 4000 ATEX, Roots pump, 230/400 V, 50 Hz; 265/460 V,60 Hz; II 3G IIB T3 +5℃ ≤ Ta≤+40℃ (PP W73 350)
  • Okta 4000 ATEX, Roots pump, 230/400 V, 50 Hz; 265/460 V,60 Hz; II 2G IIB T3 +5℃ = Ta= +40℃ (PP W73 400)
  • Okta 4000 ATEX, Roots pump, 230/400 V, 50 Hz; 265/460 V,60 Hz; II 2G IIB T3 +5℃ = Ta= +40℃ (PP W73 450)

Technical Specifications

Nominal pumping speed at 60 Hz 2,585 m³/h|1,521.53 cfm|43,083.33 l/min
Cooling type, standard air
Dimensions (length x width x height) 1356 x 502 x 458 millimeters
Add working fluid 5 liters
Working fluid P3
Daming Yi's pumping speed 2,585 m³/h|1,521.53 cfm|43,083.33 l/min
Small nominal pumping speed 1,075 m³/h|632.75 cfm|17,916.67 l/min
Nominal pumping speed 1,075-2,585 m³/h|632.75-1,521.53 cfm|17,916.67-43,083.33 l/min
leakage rate 1 · 10-6Pa m3/s|7.5 · 10-6Torr l/s|1 · 10-5mbar l/s
version ATEX with electric motor and electromagnetic clutch, locked overflow valve, ATEX according to guideline 94/9/EC: Group II, equipment category 3G, equipment group IIB, temperature class T3 X+5 ° C ≤ Ta≤ +40 °C
ambient temperature 5-40 ° C Celsius
Voltage: Range ±5 %
Motor Protection 3TF
Power Connection: Voltage 50 Hz 230/400 V
Power Connection: Voltage 60 Hz 265/460 V
speed 1,500-3,600 rpm|1,500-3,600 min-1
Emission sound pressure level at 10 hPa intake pressure (EN ISO 2151) 75 decibels (A)
Emission sound pressure level at intake pressure of 1 hPa (EN ISO 2151) 72 decibels (A)
Connecting flange (inlet) DN 150 PN 16
Connecting flange (outlet) DN 100 PN 16
Weight: with motor 390 kilograms
Protection level IP55
Rated power 50 Hz 5.5 kW
Rated power 60 Hz 6.3 kW
Rated speed 50 Hz 3,000 rpm|3,000 min-1
Rated speed 60 Hz 3,600 rpm|3,600 min-1

Maintenance of Okta 4000 ATEX vacuum pump in Pfalz, Germany

Okta 4000 ATEX, Roots pump, 230/400 V, 50 Hz, 265/460 V, 60 Hz; II 3G IIB T3 +5℃ = Ta= +40℃

Order number: PP W73 300

  • High performance Roots piston pump with suction capacity ranging from 2160 to 5190 meters3/h
  • Locked overflow valve
  • Suitable for operation with a frequency converter or for switching on when the pre vacuum pressure is sufficiently low, such as continuous operation
  • Equipped with 3-phase motor II 2G Ex de IIC T4
  • The pump is strictly sealed (leakage rate<1.10-6Pa m3/s) - Reduce the risk of regional contamination to a low level
  • Pressure impact strength in accordance with EN 1333 and PN grade 16
  • Thanks to the safe structure and temperature monitoring device, explosion-proof safety is achieved - installation can be carried out without the need for additional flame arresters
  • Tip: The terms specified in the operating instructions apply to the operation of the pump. We are dedicated to providing consultation for your use!
  • Scope of work: In accordance with the provisions of guideline 2014/34/EU, both the internal and external parts of the pump are suitable for use in equipment group II, equipment category 3 (G), for gases and vapors used in explosion groups IIA and IIB at temperature level T3.
  • Maintenance of Okta 4000 ATEX vacuum pump in Pfalz, Germany

The pump is suitable for frequency converter operation.
Offset motor voltage 50 Hz: 200 V, 220/380 V, 380/660 V, 415 V and 60 Hz: 200 V, 220/380 V, 230/400 V, 380/660 V, 400/690 V, 440/760 V, 480 V available.
Stainless steel 1.4059 material can be supplied upon consultation.
According to guideline 2014/34/EU, equipment category 2 can be supplied upon consultation.

Nominal pumping speed at 60 Hz 5,190 m³/h|3,054.83 cfm|86,500 l/min
Cooling type, standard air
Dimensions (length x width x height) 1651 x 655 x 560 millimeters
Add working fluid 6.8 liters
Working fluid P3
Daming Yi's pumping speed 5,190 m³/h|3,054.83 cfm|86,500 l/min
Small nominal pumping speed 2,160 m³/h|1,271.38 cfm|36,000 l/min
Nominal pumping speed 2,160-5,190 m³/h|1,271.38-3,054.83 cfm|36,000-86,500 l/min
leakage rate 1 · 10-6Pa m3/s|7.5 · 10-6Torr l/s|1 · 10-5mbar l/s
version ATEX with electric motor and electromagnetic clutch, locked overflow valve, ATEX according to guideline 94/9/EC: Group II, equipment category 3G, equipment group IIB, temperature class T3 X+5 ° C ≤ Ta≤ +40 °C
ambient temperature 5-40 ° C Celsius
Voltage: Range ±5 %
Motor Protection 3TF
Power Connection: Voltage 50 Hz 230/400 V
Power Connection: Voltage 60 Hz 265/460 V
speed 1,500-3,600 rpm|1,500-3,600 min-1
Emission sound pressure level at 10 hPa intake pressure (EN ISO 2151) 79 decibels (A)
Emission sound pressure level at intake pressure of 1 hPa (EN ISO 2151) 74 decibels (A)
Connecting flange (inlet) DN 250 PN 16
Connecting flange (outlet) DN 150 PN 16
Weight: with motor 700 kilograms
Protection level IP55
Rated power 50 Hz 11 kilowatts
Rated power 60 Hz 13 kilowatts
Rated speed 50 Hz 3,000 rpm|3,000 min-1
Rated speed 60 Hz 3,600 rpm|3,600 min-1

size

尺寸图-TIM-RS

A

1651 millimeters

B

678 millimeters

C

560 millimeters

D

400 millimeters

Product Features

Suzhou Kunshan Taicang Wuxi Shanghai Zhangjiagang Wujiang Changshu Zhenjiang German pfeiffer vacuum pump Okta 2000 ATEX maintenance and repair, LNG interlayer vacuum system, Duwa tank gas cylinder vacuum system

Changzhou Yangzhou Taizhou Nantong Nanjing Qidong Haimen Rugao HaimenGerman pfeiffer vacuum pump Okta 2000 ATEX maintenance and repair, LNG interlayer vacuum system, Duwa tank gas cylinder vacuum system

Hai'an Xinyang Zaozhuang Qufu Dezhou Rudong Suqian Xuzhou HefeiGerman pfeiffer vacuum pump Okta 2000 ATEX maintenance and repair, LNG interlayer vacuum system, Duwa tank gas cylinder vacuum system

Wuhu Hangzhou Huzhou Wenzhou Taizhou Quzhou Shaoxing Jinhua NingboGerman pfeiffer vacuum pump Okta 2000 ATEX maintenance and repair, LNG interlayer vacuum system, Duwa tank gas cylinder vacuum system

Yuyao, Fuzhou, Xiamen, Ganzhou, Xiangtan, Changsha, Enshi, Tongxiang, TongchengGerman pfeiffer vacuum pump Okta 2000 ATEX maintenance and repair, LNG interlayer vacuum system, Duwa tank gas cylinder vacuum system

Bengbu Quanzhou Shenzhen Guangzhou Zhuhai Guangzhou Huizhou Tongzhou GuilinGerman pfeiffer vacuum pump Okta 2000 ATEX maintenance and repair, LNG interlayer vacuum system, Duwa tank gas cylinder vacuum system

Nanning Nanchang Ganzhou Wuhan Chengdu Chongqing Jingzhou Taiyuan LanzhouGerman pfeiffer vacuum pump Okta 2000 ATEX maintenance and repair, LNG interlayer vacuum system, Duwa tank gas cylinder vacuum system

Urumqi Jingjiang Danyang Shijiazhuang Tianjin Changchun Jilin JinanGerman pfeiffer vacuum pump Okta 2000 ATEX maintenance and repair, LNG interlayer vacuum system, Duwa tank gas cylinder vacuum system

Qingdao Weihai Dezhou Lianyungang Kunming Jiujiang Anqing Xinxiang SuqianGerman pfeiffer vacuum pump Okta 2000 ATEX maintenance and repair, LNG interlayer vacuum system, Duwa tank gas cylinder vacuum system

Huai'an Dongying Quzhou Jinhua Lishui Yingtan Jiujiang XinyuGerman pfeiffer vacuum pump Okta 2000 ATEX maintenance and repair, LNG interlayer vacuum system, Duwa tank gas cylinder vacuum system

1、 Imported vacuum pump maintenance:
1. BOC EDWARDS: GV series (GV600, GV600-EH4200), IQDP series (IQDP80), QDP series, DP series, E1M series, E2M series, EH series, QMB series, RV series, ESDP12, GVSP30, etc.
2. ALCATEL: ADS series (ADS 602H/P, ADS1802H/P), ADP series (ADP122), ACP series (ACP28, ACP40), RHV series, SD series, C1 series, C2 series, I series, H1 series, A series, etc.
3. LEYBOLD: SV series (SV65B, etc.), SC series, DIVAC series, DK series, DRYVAC series, WS series, SP series, TRIVAC series, WH/WHU series, etc
4. EBARA: A series, AV series, AW series, AA series, AAS series, X series, etc.
5. KASHIYAMA: MU series, SDE series, SDL series, KMB series, NeoDRY series, etc.
6. ORION: KRX series, CBX series, KRF series, KHF series, KHA series, KRA series, KHH series, etc.
7. BECKER: U series, VT series, KVT series, VTLF series, T series, DVT series, DVTLF series, etc.
8. RIETSCHLE: VCA/AH/CB/CE/CEH/CH/GD oil rotary vane vacuum pump series, CF/F/FD/FDE/FE/FEH/FG/FT/FZ dry rotary vane vacuum/compression pump series, VL/DT/KT dry rotary vane vacuum/compression pump series, etc.
9. ULVAC: GLD oil rotary vane vacuum pump series, VDN/VSN oil selection vane vacuum pump series, PVD oil rotary vane vacuum pump series, etc.
10. VIRIAN: DS/HS/SD/CD series oil rotary vane vacuum pump series, TS/DS dry vacuum pump series, etc.
11、IWATA(岩田)DVSL-100C/ISP-50/ISP-90/ISP-250C/ISP-500C/ISPC-1000/GVSC-500B/GVSC-501B/
12、HANBELL(汉钟)PS80/PS160/PS180/PS602/PS902/PS1302/PS1802/PD300/PD500/PD1902/PD2152/PD3052/PD3652