Maintenance of Okta 1000 ATEX vacuum pump from Pfalz, Germany

NegotiableUpdate on 05/12
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

1. Strictly sealed, through electromagnetic clutch, leakage rate amp; amp; lt; 1 amp; amp; #183; 10-6 Pa m3/s2、 Equipped with 3-phase motor II 2G EX de IIC T4 $r $n3, shock resistant range up to 1600 kPa4, no thermal overload due to integrated temperature sensor 5, used for ATEX (guideline 2014/34/EU) applications, German Pfalz vacuum pump Okta 1000 ATEX maintenance

Product Details

ATEX certified magnetic coupled Roots pump suitable for medium and low vacuum applications
We have developed ATEX certified pumps based on the 2014/34/EU standard for the evacuation of explosive gases and the process flow in explosive environments to meet strict explosion-proof requirements.Maintenance of Okta 1000 ATEX vacuum pump from Pfalz, Germany

The pumping speed range of Roots pump is 280 to 5190 m3/Within h. According to the different requirements of the application, you can choose device type 2 or type 3. All pumps are suitable for T3 temperature rating.

In Roots pumps, the gearbox and bearing belt are separated from the air pump chamber. Because the rotor operates under frictionless conditions, it ensures a dry operating environment.Maintenance of Okta 1000 ATEX vacuum pump from Pfalz, Germany

Product advantages

  • High explosion-proof safety performance - According to PN 16, explosion-proof safety is achieved through anti pressure surge technology
  • No additional fire extinguishing device is required during installation
  • The vacuum pump has good sealing performance (leakage rate less than 10%)-6Pa m3/s) - No inclusion of explosive gases
  • High reliability - using an integrated temperature sensor to effectively prevent the pump body from overheating
  • The vacuum pump can be operated directly (with ATEX protection when passive rotation is caused by the preceding vacuum airflow)
  • On site maintenance is simple and easy to operate, and the engine is no exception (using standardized ATEX IEC engines that can be directly replaced on site)
  • Due to different differential pressures and speeds (when using a frequency converter), the application has high flexibility

application

  • heat treatment
  • vacuum drying
  • vacuum furnace
  • biotechnology

This vacuum pump has another significant advantage, due to the use of convective cooling technology, the operating cost is significantly lower than that under water cooling conditions. Therefore, this vacuum pump can be widely applied in various fields. We have a very mature design concept in the design of Roots pumps, which has now developed into related designs involving magnetic coupling. Thanks to the excellent sealing performance of the vacuum pump, the product can achieve extremely low leakage rates.

Inhalation capacity of 280 to 670 meters3/H's Roots piston pump:

Product Description

  • Strictly sealed, through electromagnetic clutch, leakage rate<1.10-6Pa m3/s
  • Equipped with 3-phase motor II 2G EX de IIC T4
  • Seismic impact range up to 1600 kPa
  • No thermal overload due to integrated temperature sensor
  • For applications within the scope of ATEX (Directive 2014/34/EU)

Okta 1000 ATEX

Having a length of 590-1.420 meters3/Roots pump with suction capacity:

Product Description

  • Strictly sealed, through electromagnetic clutch, leakage rate<1.10-6Pa m3/s
  • Equipped with 3-phase motor II 2G EX de IIC T4
  • Seismic impact range up to 1600 kPa
  • No thermal overload due to integrated temperature sensor
  • For applications within the scope of ATEX (Directive 2014/34/EU)

product

  • Okta 1000 ATEX, Roots pump, 230/400 V, 50 Hz; 265/460 V,60 Hz; II 3G IIB T3 +5℃ = Ta= +40℃ (PP W43 300)
  • Okta 1000 ATEX, Roots pump, 230/400 V, 50 Hz; 265/460 V,60 Hz; II 3G IIB T3 +5℃ ≤ Ta≤40℃ (PP W43 350)
  • Okta 1000 ATEX, Roots pump, 230/400 V, 50 Hz; 265/460 V,60 Hz; II 2G IIB T3 +5℃ = Ta= +40℃ (PP W43 400)
  • Okta 1000 ATEX, Roots pump, 230/400 V, 50 Hz; 265/460 V,60 Hz; II 2G IIB T3 +5℃ ≤ Ta≤40℃ (PP W43 450)

Okta 1000 ATEX, Roots pump, 230/400 V, 50 Hz; 265/460 V,60 Hz; II 3G IIB T3 +5℃ = Ta= +40℃

Order number: PP W43 300

  • Having a length of 590-1420 meters3/High performance Roots pump with suction capacity
  • Locked overflow valve
  • Suitable for operation with a frequency converter or for switching on when the pre vacuum pressure is sufficiently low, such as continuous operation
  • Equipped with 3-phase motor II 2G Ex de IIC T4
  • The pump is strictly sealed (leakage rate<1.10-6Pa m3/s) - Reduce the risk of regional contamination to a low level
  • Pressure impact strength in accordance with EN 1333 and PN grade 16
  • Thanks to the safe structure and temperature monitoring device, explosion-proof safety is achieved - installation can be carried out without the need for additional flame arresters
  • Tip: The terms specified in the operating instructions apply to the operation of the pump. We are dedicated to providing consultation for your use!
  • Scope of work: In accordance with the provisions of guideline 2014/34/EU, both the internal and external parts of the pump are suitable for use in equipment group II, equipment category 3 (G), for gases and vapors used in explosion groups IIA and IIB at temperature level T3.

The pump is suitable for frequency converter operation.
Offset motor voltage 50 Hz: 200 V, 220/380 V, 380/660 V, 415 V and 60 Hz: 200 V, 220/380 V, 230/400 V, 380/660 V, 400/690 V, 440/760 V, 480 V available.
Stainless steel 1.4059 material can be supplied upon consultation.
According to guideline 2014/34/EU, equipment category 2 can be supplied upon consultation.

    The pump is suitable for frequency converter operation.
    Offset motor voltage 50 Hz: 200 V, 220/380 V, 380/660 V, 415 V and 60 Hz: 200 V, 220/380 V, 230/400 V, 380/660 V, 400/690 V, 440/760 V, 480 V available.
    Stainless steel 1.4059 material can be supplied upon consultation.
    According to guideline 2014/34/EU, equipment category 2 can be supplied upon consultation.

    Technical Specifications

    Nominal pumping speed at 60 Hz 1,420 m³/h|835.81 cfm|23,666.67 l/min
    Cooling type, standard air
    Dimensions (length x width x height) 1146 x 458 x 402 millimeters
    Add working fluid 2.9 liters
    Working fluid P3
    Daming Yi's pumping speed 1,420 m³/h|835.81 cfm|23,666.67 l/min
    Small nominal pumping speed 590 m³/h|347.27 cfm|9,833.33 l/min
    Nominal pumping speed 590-1,420 m³/h|347.27-835.81 cfm|9,833.33-23,666.67 l/min
    leakage rate 1 · 10-6Pa m3/s|7.5 · 10-6Torr l/s|1 · 10-5mbar l/s
    version ATEX with electric motor and electromagnetic clutch, locked overflow valve, ATEX according to guideline 94/9/EC: Group II, equipment category 3G, equipment group IIB, temperature class T3 X+5 ° C ≤ Ta≤ +40 °C
    ambient temperature 5-40 ° C Celsius
    Voltage: Range ±5 %
    Motor Protection 3TF
    Power Connection: Voltage 50 Hz 230/400 V
    Power Connection: Voltage 60 Hz 265/460 V
    speed 1,500-3,600 rpm|1,500-3,600 min-1
    Emission sound pressure level at 10 hPa intake pressure (EN ISO 2151) 75 decibels (A)
    Emission sound pressure level at intake pressure of 1 hPa (EN ISO 2151) 72 decibels (A)
    Connecting flange (inlet) DN 150 PN 16
    Connecting flange (outlet) DN 100 PN 16
    Weight: with motor 290 kilograms
    Protection level IP55
    Rated power 50 Hz 3 kilowatts
    Rated power 60 Hz 3.5 kilowatts
    Rated speed 50 Hz 3,000 rpm|3,000 min-1
    Rated speed 60 Hz 3,600 rpm|3,600 min-1

    size

    尺寸图-TIM-RS

    A

    1146 millimeters

    B

    461 millimeters

    C

    402 millimeters

    D

    266 millimeters

    Product Features

    Suzhou Kunshan Taicang Wuxi Shanghai Zhangjiagang Wujiang Changshu Zhenjiang German pfeiffer vacuum pump Okta 1000 ATEX maintenance and repair, LNG interlayer vacuum system, Duwa tank gas cylinder vacuum system

    Changzhou Yangzhou Taizhou Nantong Nanjing Qidong Haimen Rugao HaimenGerman pfeiffer vacuum pump Okta 1000 ATEX maintenance and repair, LNG interlayer vacuum system, Duwa tank gas cylinder vacuum system

    Hai'an Xinyang Zaozhuang Qufu Dezhou Rudong Suqian Xuzhou HefeiGerman pfeiffer vacuum pump Okta 1000 ATEX maintenance and repair, LNG interlayer vacuum system, Duwa tank gas cylinder vacuum system

    Wuhu Hangzhou Huzhou Wenzhou Taizhou Quzhou Shaoxing Jinhua NingboGerman pfeiffer vacuum pump Okta 1000 ATEX maintenance and repair, LNG interlayer vacuum system, Duwa tank gas cylinder vacuum system

    Yuyao, Fuzhou, Xiamen, Ganzhou, Xiangtan, Changsha, Enshi, Tongxiang, TongchengGerman pfeiffer vacuum pump Okta 1000 ATEX maintenance and repair, LNG interlayer vacuum system, Duwa tank gas cylinder vacuum system

    Bengbu Quanzhou Shenzhen Guangzhou Zhuhai Guangzhou Huizhou Tongzhou GuilinGerman pfeiffer vacuum pump Okta 1000 ATEX maintenance and repair, LNG interlayer vacuum system, Duwa tank gas cylinder vacuum system

    Nanning Nanchang Ganzhou Wuhan Chengdu Chongqing Jingzhou Taiyuan LanzhouGerman pfeiffer vacuum pump Okta 1000 ATEX maintenance and repair, LNG interlayer vacuum system, Duwa tank gas cylinder vacuum system

    Urumqi Jingjiang Danyang Shijiazhuang Tianjin Changchun Jilin JinanGerman pfeiffer vacuum pump Okta 1000 ATEX maintenance and repair, LNG interlayer vacuum system, Duwa tank gas cylinder vacuum system

    Qingdao Weihai Dezhou Lianyungang Kunming Jiujiang Anqing Xinxiang SuqianGerman pfeiffer vacuum pump Okta 1000 ATEX maintenance and repair, LNG interlayer vacuum system, Duwa tank gas cylinder vacuum system

    Huai'an Dongying Quzhou Jinhua Lishui Yingtan Jiujiang XinyuGerman pfeiffer vacuum pump Okta 1000 ATEX maintenance and repair, LNG interlayer vacuum system, Duwa tank gas cylinder vacuum system

    1、 Imported vacuum pump maintenance:
    1. BOC EDWARDS: GV series (GV600, GV600-EH4200), IQDP series (IQDP80), QDP series, DP series, E1M series, E2M series, EH series, QMB series, RV series, ESDP12, GVSP30, etc.
    2. ALCATEL: ADS series (ADS 602H/P, ADS1802H/P), ADP series (ADP122), ACP series (ACP28, ACP40), RHV series, SD series, C1 series, C2 series, I series, H1 series, A series, etc.
    3. LEYBOLD: SV series (SV65B, etc.), SC series, DIVAC series, DK series, DRYVAC series, WS series, SP series, TRIVAC series, WH/WHU series, etc
    4. EBARA: A series, AV series, AW series, AA series, AAS series, X series, etc.
    5. KASHIYAMA: MU series, SDE series, SDL series, KMB series, NeoDRY series, etc.
    6. ORION: KRX series, CBX series, KRF series, KHF series, KHA series, KRA series, KHH series, etc.
    7. BECKER: U series, VT series, KVT series, VTLF series, T series, DVT series, DVTLF series, etc.
    8. RIETSCHLE: VCA/AH/CB/CE/CEH/CH/GD oil rotary vane vacuum pump series, CF/F/FD/FDE/FE/FEH/FG/FT/FZ dry rotary vane vacuum/compression pump series, VL/DT/KT dry rotary vane vacuum/compression pump series, etc.
    9. ULVAC: GLD oil rotary vane vacuum pump series, VDN/VSN oil selection vane vacuum pump series, PVD oil rotary vane vacuum pump series, etc.
    10. VIRIAN: DS/HS/SD/CD series oil rotary vane vacuum pump series, TS/DS dry vacuum pump series, etc.
    11、IWATA(岩田)DVSL-100C/ISP-50/ISP-90/ISP-250C/ISP-500C/ISPC-1000/GVSC-500B/GVSC-501B/
    12、HANBELL(汉钟)PS80/PS160/PS180/PS602/PS902/PS1302/PS1802/PD300/PD500/PD1902/PD2152/PD3052/PD3652