The float of the magnetic flap level gauge uses a float with a magnetic ring to rise or fall with the liquid level, causing the corresponding position of the reed switch to be attracted and converted into a corresponding electrical signal output for indication measurement. The structure consists of a magnetic float, a measuring conduit, a signal unit, etc
Magnetic flap level gauge floatUsing a float with a magnetic ring to rise or fall with the liquid level, the corresponding position of the reed switch is attracted and converted into a corresponding electrical signal output for indication and measurement. The structure consists of a magnetic float, measuring conduit, signal unit, etc
Technical Specifications
1. Measurement range: 500-6000mm Basic error: ± 1% FS
2. Dielectric density: ≥ 0.7g/cm3 Load resistance: ≤ 750 Ω
3. Medium temperature: -20~+120 ℃ Output signal: 4~20mmA.DC
4. Work pressure:<1.6MPa Power supply: 24V DC
5. Explosion proof grade: DIIBT4 Explosion proof certificate number: GYB03163
Parameter table:
| serial number | Standard Number | DN | PN(MPa) | D | K | 突面 (RF) | n-L |
| 1 | HG20593-97 | 100 | 1.0 1.6 | 220 | 180 | 156 | 8-18 |
| 2 | 125 | 250 | 210 | 184 |
Installation and Usage
1. The installation position of the liquid level gauge should be selected at a location where the fluctuation of the liquid medium is small and the inlet and outlet of the medium should be avoided or kept as far away as possible to reduce the impact of the medium fluctuation on it.
For level gauges with a length of more than 3 meters, the bottom of the conduit should be positioned to increase its strength and stability.
3. The medium inside the tank (especially around the conduit) is not allowed to have magnetic conductors or impurities, in order to avoid jamming the float and affecting the normal operation of the level gauge.
Ordering Instructions
When selecting and ordering, please correctly indicate the various technical parameters in the product naming and specify the name of the measuring medium.
2. If the product model does not match the above product model due to special user needs, please indicate your special technical requirements or contact the relevant responsible department of our company to place a special order.