project name
|
HDI
|
|
control mode
|
SPWM
|
|
Input power supply
|
380VPower Supply:330~440V;220VPower Supply:170~240
|
|
Five digit digital display
And status indicator lights
|
Display frequency, current, speed, voltage, counter, temperature, forward and reverse status, faults, etc.
|
|
Communication Control
|
RS-485
|
|
operate temperature
|
-10~40℃
|
|
humidity
|
0~95%Relative humidity (non condensing)
|
|
vibrate
|
0.5Gbelow
|
|
frequency control
|
range
|
0.10~400.00Hz
|
|
accuracy
|
Digital:0.01%(-10~40℃); Simulated:0.1%(25±10℃)
|
|
Set resolution
|
Digital:0.01Hz; Analog: Maximum operating frequency1‰
|
|
output resolution
|
0.01Hz
|
|
Keyboard setting method
|
You can directly use ←∧∨setting
|
|
Simulation setting method
|
External voltage0-5V,0-10V,4—20mA,0—20mA.
|
|
Other functions
|
The lower limit of frequency, starting frequency, stopping frequency, and three jumping frequencies can be set separately
|
|
general control
|
Acceleration and deceleration control
|
4Segment acceleration and deceleration time(0.1-6500Choose freely in seconds
|
|
V/Fcurve
|
Can be set arbitrarilyV/Fcurve
|
|
Torque control
|
Can set torque boost, maximum10%The starting torque is1.0HzTime reachable150%
|
|
Multi functional input terminal
|
6Multiple multifunctional input terminals, realizing8Segment speed control, program execution,4Switching between acceleration and deceleration,UP、DOWNFunctions such as functionality, counter, external emergency stop, etc
|
|
Multi functional output terminal
|
have5Multiple multifunctional output terminals, realizing indication and alarm of running, zero speed, counter, external abnormalities, program operation, etc
|
|
Other functions
|
Automatic voltage stabilization(AVR)Deceleration stop or free stop, DC brake, automatic reset and restart, frequency tracking,PLCProgram control, lateral control, adjustable carrier, up to20KHzclass
|
|
Protection function
|
overload protection
|
Electronic relay protection motor
Driver (constant torque)150%/1Minutes, fan class120%/1Minutes)
|
|
FUSEfuse protection
|
FUSECircuit breaker, motor stops
|
|
Overvoltage
|
220VLine: DC voltage>400V;380VLine: DC voltage>800V
|
|
Insufficient voltage
|
220VLine: DC voltage<200V;380VLine: DC voltage<400V
|
|
Instant power outage and restart
|
After a sudden stop, it can be restarted in frequency tracking mode
|
|
Stall Prevention
|
add/Preventing stall during deceleration operation
|
|
Short circuit at output end
|
Electronic circuit protection
|
|
Other functions
|
Overheating protection for heat sinks, reverse restriction, direct start-up and fault recovery after startup, parameter locking, etc.
|