23rd Floor, Unit 2, Building 16, Binhu City, Tianchang City, Anhui Province
Anhui Maoshu Instrument Co., Ltd
664688125@qq.com
18255085484
23rd Floor, Unit 2, Building 16, Binhu City, Tianchang City, Anhui Province
Thermocouple input signal isolator (supporting output circuit power supply)
1、 Characteristics
MS7911(1入1出)、MS7912(1入2出 )
·Suitable for thermocouples such as K, E, S, B, etc
·Output 4-20mA
Independent DC power supply and support output circuit power supply
2、 Technical specifications
|
·Suitable for thermocouple or other millivolt signal input, after isolation, converted into standard 4-20mA current signal output to control system or other instruments. ·The thermocouple temperature transmitter is powered by an independent DC power supply and supports transmission loop power supply, with isolation between the power supply input output. Standard 35mm DIN rail card installation. Plug and unplug terminal block with spring compression connection. ● Input Input thermocouple: K; E; S;B; R;T; N;W; J and other types of thermocouples Optional millivolt signal input: -5-+60mV range; ***Small millivolt range: 3mV ● Output Output current (lo): 4-20mA Output circuit power supply voltage (Ue): 12-35V Voltage drop (Ud): 5V Output load resistance (RL): Calculation formula RL ≤ (Ue Ud) ÷ 0.02 Output ripple:<10mVp-p Note: The selection of power supply voltage for the output circuit should be determined based on the size of the load. If the voltage is too high and the load is very small, it will aggravate the heating condition of the isolator. ) |
● Power supply Power supply voltage range: 20~30VDC Rated supply voltage: 24VDC Current consumption (when powered by 24VDC):<30mA (1 in 1 out) <42mA (1 in 2 out) Standard accuracy: ± 0.1% (see thermocouple type, range, and measurement error table) Cold end temperature error: ± 1 ℃ Cold end temperature compensation range: -5~+60 ℃ (Cold end compensation resistor has been installed inside the temperature transmitter) Temperature drift: Basic error/10 ℃ Response time:<10ms Compensation temperature stabilization time:<1 minute Isolation capability: 2.5KV, 1min, 50Hz between input output power supply Insulation resistance: ≥ 100M Ω/500VDC between input output power supply Working environment temperature: -20~+60 ℃ Storage environment temperature: -40~+80 ℃ Shell material/protection level: PC (polycarbonate) material/IP20 Dimensions: 16 × 116 × 110 (mm) |
3、 Model selection

![]()
![]()
4、 Dimensions and installation diagram
● Installation
1.35mm standard DIN rail card installation. Please pay attention to the stability and firmness of the card position during installation.
2. Install vertically as much as possible to facilitate heat dissipation inside the instrument.
● Typical applications
1. Used to provide distribution voltage to on-site transmitters and isolate and convert input signals.
2. Devices connected to the site: Active electrical signals from two-wire or three wire non smart transmitters.
3. Connect to the control system (or other unit combination instruments): The AI card of each DCS/PLC receives current or voltage signals.

● External dimensions
Width (thickness) x height x depth=16 x 116 x 110 (mm)

5、 Terminal wiring diagram
Terminal wiring: Plug and unplug terminal blocks, connected by self boosting spring type compression. The cross-sectional area of the wire shall not exceed 2.5mm2Multiple bundles or single stranded cables.