MS6053 DC signal input isolated safety barrier (one in, two out) I. Characteristics ● Input DC signals from various intrinsically safe equipment in hazardous sites

Product Details

MS6053DC signal input isolated safety barrier (one in, two out)

1、 Characteristics
Input the DC signals of various intrinsic safety devices at hazardous sites.
Standard analog signal electrical isolation.
Linearization conversion output, selectable420mAperhaps15VSignal and other required DC signals.
Modular core design, with digital calibration internally, eliminating the need for zero and full adjustment potentiometers, and automatic compensation for temperature drift.
Equipped with a working power indicator light.
One input, isolated into two outputs, intrinsically safe input circuit[Exia]IICInput circuit short circuit protection.
Plug and unplug terminal block,DINRail card installation.
2、 Description
MS6053DC signal input isolation safety barrier is used to isolate and limit the DC signal input connected to hazardous areas. It is then converted and distributed into two standard process signals for output to the control system or other intelligent instruments in the safety zone.
This isolated safety barrier requires independent power supply, with electromagnetic isolation between the power supply input circuit output circuit.
3、 Technical specifications

Product model:MS6053
Model specifications (code)
The code indicates the range of signal input or output, and users can freely choose it when placing an order (see selection spectrum).
Working power supply
Power wiring: independent wiring terminals13-,14+, can be plugged and unplugged with electricity
Power supply voltage:20~35VDC
aftermathWpp:<5
Current loss: approximately80mA
Power indicator: When powered onLEDThe light is on; green
Input circuit(Exia IICDangerous Zone
Input channel: Terminal1-,2+Wiring (see terminal wiring diagram)
Current signal:420mA020mA; or specify the current range
Voltage signal:15V05V010V; or specify voltage range
Input impedance: Built in input resistor50Ω
Output circuit (safe zone)
Two channel isolated output
******Output channel: terminal10,11,12Wiring (see terminal wiring diagram)
Second output channel: terminal7,8,9Wiring (see terminal wiring diagram)
Output current:420mA020mA; or specify the current range
Allowable load during current output:0550Ω420mA020mAWhen outputting)
Output voltage:15V05V010V; or specify voltage range
Voltage output impedance: Built in output resistor250Ω

Precision:±0.1%FS
Temperature drift:±0.015%/℃
Response time:≤1s0 → 90%
Stable time:≤3s
The impact of power supply voltage fluctuations:±0.1%(Allowable voltage range)
The impact of changes in load resistance:±0.1%/250Ω
Channel isolation: input-output1- Output2- Isolation between power sources
Insulation resistance:≥100MΩ/500V DCAC
Isolation ability:1500VAC/1minute50Hz
Safe and Dangerous Zones
Isolation voltage between:250VAC
Electromagnetic compatibility: compliant withIEC61000Related anti electromagnetic standards
Environmental parameters
Working temperature:0~+60℃
Storage and transportation temperature: -20~+80℃
ambient humidity:5~+95RH(No condensation)
Structure and external dimensions
structure:centralizers;Modular watch core;ABSMaterial shell;Plug in terminal
External dimensions:W16×H116×D110(mm),Refer to the external dimension diagram
Whole machine weight: approximately115g
Safety and Explosion proof Certification Parameters: The entire machine meets the requirementsGB3836.1-2000andGB3836.42000Standard related requirements
Explosion proof grade mark: IIC

***High safety voltage (Um): 250VAC/DC

(Terminals 1-2, 4-5) Uo: 7.2V Io: 3.7mA Po: 7mW Lo: 2.4mH Co: 4 μ F

4、 Model selection

11.jpg22.jpg

5、 Dimensions and installation diagram
install
1.35mmstandardDINRail card installation. Please pay attention to the stability and firmness of the card position during installation.
2.Install vertically as much as possible to facilitate heat dissipation inside the instrument.
Typical applications
1. Suitable for isolating and converting on-site signal inputs: one input and two outputs of the signal.
2. Suitable for devices connected to the site: two-wire or three wire non intelligent transmitters, active current signals.
3. The area where the on-site equipment is located:0District1District2DistrictIIADistrictIIBDistrictIICDistrictT4~T6Dangerous zone.
4. Safety barrier output connection: can be connected to unit combination instruments andDCS/PLCWaiting for the system to be used in conjunction.

3.jpg

External dimensions
Width (thickness)×tall×Deep=16×116×110mm

2.jpg

6、 Terminal wiring diagram
Terminal wiring: Plug and unplug terminal blocks, connected by self boosting spring type compression. The cross-sectional area of the wire shall not exceed2.5mm2Multiple bundles or single stranded cables.