MS6043 signal distribution input isolated safety barrier (one in, two out) I. Characteristics ● Provides a driving voltage of 16.5-28V to the transmitter

Product Details

MS6043signalpower distributionInput isolated safety barrier (one in, two out)

1、 Characteristics
Provide driving voltage to the transmitter16.528V.
Transfer the transmitter420mASignal isolation transmission.
selectable420mAperhaps15VSignal output, or other required DC signals.
Modular core design, with digital calibration internally, eliminating the need for zero and full adjustment potentiometers, and automatic compensation for temperature drift.
Equipped with a working power indicator light.
Single channel, one input, isolated into two outputs, intrinsically safe input circuit[Exia]IICInput circuit short circuit protection.
Plug and unplug terminal block,DINRail card installation.
2、 Description
MS6043On site power signal input isolation safety barrier is used to provide isolated power voltage to transmitters in hazardous areas on site, and to convert the power generated by the transmitters420mAThe signal is converted and distributed into two independent DC signals through this isolated safety barrier to the safety zone control system or other intelligent instruments.
Alternatively, the direct current signal of intrinsically safe equipment in hazardous areas on site can be selected,Transported through this isolated safety barrier,Isolate and convert into two independent DC signal outputs
This isolated safety barrier requires independent power supply, with electromagnetic isolation between the power supply input circuit output circuit.
3、 Technical specifications

Product model:MS6043
Model specification (code):
The code indicates the range of signal input or output, and users can freely choose it when placing an order (see selection spectrum).
Working power supply:
Power wiring: independent wiring terminals13-,14+, can be plugged and unplugged with electricity
Power supply voltage:20~35VDC
aftermathWpp:<5
Current loss: approximately80mA
Power indicator: When powered onLEDLight on: green
Input circuit(Exia IICDangerous Zone
Input channel: Terminal123 Wiring (see terminal wiring diagram)
Transmitter signal input:420mA
Distribution voltage for driving the transmitter:16.528V
Optional current source signal input:420mA020mA; or specify the current range
Input impedance: Built in input resistor50Ω
Output circuit (safe zone)
Two channel isolated output
auxiliary word for ordinal numbers One output channel:terminal10,11,12Wiring (see terminal wiring diagram)
Second output channel: terminal789 Wiring (see terminal wiring diagram)
Output current:420mA020mA; or specify the current range
Allowable load during current output:0550Ω420mA020mAWhen outputting)
Output voltage:15V05V010V; or specify voltage range
Voltage output impedance:Built in output resistor250Ω
performance index
Standard accuracy:±0.1%FS

Temperature drift:±0.015%/℃
Response time:≤1s0→ 90%
Stable time:≤3s
The impact of power supply voltage fluctuations:±0.1%(Allowable voltage range)
The impact of changes in load resistance:±0.1%/250Ω
Channel isolation: isolation between input output power supply
Insulation resistance:≥100MΩ/500VDCAC
Isolation ability:1500VAC/1minute50Hz
Isolation voltage between safe and hazardous areas:250VAC
Electromagnetic compatibility: compliant withIEC61000Related anti electromagnetic standards
Environmental parameters
Working temperature:0~+60℃
Storage and transportation temperature: -20~+80℃
ambient humidity:5~+95RH(No condensation)
Structure and external dimensions
Structure: card mounted; Modular watch core;ABSMaterial casing; Plug in terminal letters
External dimensions:W16×H116×D110mm)Refer to the external dimension diagram
Whole machine weight: approximately120g
Safety and Explosion proof Certification Parameters:
The whole machine meets the requirementsGB3836.1-2000andGB3836.42000Standard related requirements
Explosion proof grade mark: IIC

***High safety voltage (Um): 250VAC/DC

(Terminals 2-3, 4-5) Uo: 26.2V Io: 127mA Po: 0.83W Lo: 1.4mH Co: 0.05 μ F

(Terminal 1-2) Uo: 7.2V Io: 3.7mA Po: 7mW Lo: 2.4mH Co: 4 μ F

4、 Model selection

11.jpg 22.jpg

5、 Dimensions and installation diagram
install
1.35mmstandardDINRail card installation. Please pay attention to the stability and firmness of the card position during installation.
2.Install vertically as much as possible to facilitate heat dissipation inside the instrument.
Typical applications
1. Suitable for isolating and converting on-site signal inputs: one input and two outputs of the signal.
2. Suitable for devices connected to the site: two-wire or three wire non intelligent transmitters, active current signals.
3. The area where the on-site equipment is located:0District1District2DistrictIIADistrictIIBDistrictIICDistrictT4~T6Dangerous zone.
4. Safety barrier output connection: can be connected to unit combination instruments andDCS/PLCWaiting for the system to be used in conjunction.

3.jpg

External dimensions
Width (thickness)×tall×Deep=16×116×110mm

2.jpg

6、 Terminal wiring diagram
Terminal wiring: Plug and unplug terminal blocks, connected by self boosting spring type compression. The cross-sectional area of the wire shall not exceed2.5mm2Multiple bundles or single stranded cables.

1.jpg