1、 Characteristics
●Provide driving voltage to the transmitter16.5~28V.
●Transfer the transmitter4~20mASignal isolation transmission.
●selectable4~20mAperhaps1~5VSignal output, or other required DC signals.
●Modular core design, with digital calibration internally, eliminating the need for zero and full adjustment potentiometers, and automatic compensation for temperature drift.
●Equipped with a working power indicator light.
●Single channel, one input and one output, intrinsic safety input circuit[Exia]IICInput circuit short circuit protection.
●Plug and unplug terminal block,DINRail card installation.
2、 Description
①MS6041signalpower distributionInput isolation safety barrier is a device that provides isolated power voltage to transmitters in hazardous areas on site and converts the voltage generated by the transmitters4~20mAThe signal is converted into the required DC signal through this isolated safety barrier and sent to the safety zone control system or other intelligent instruments.
②Alternatively, the direct current signal of intrinsically safe equipment in hazardous areas on site can be selected,Transported through this isolated safety barrier,Isolate and convert to the required DC signal output.
③This isolated safety barrier requires independent power supply, with electromagnetic isolation between the power supply input circuit output circuit.
3、 Technical specifications
●Product model:MS6041 |
●performance index ***High safety voltage (Um): 250VAC/DC (Terminals 2-3, 4-5) Uo: 26.2V Io: 127mA Po: 0.83W Lo: 1.4mH Co: 0.05 μ F (Terminal 1-2) Uo: 7.2V Io: 3.7mA Po: 7mW Lo: 2.4mH Co: 4 μ F
|
4、 Model selection

5、 Dimensions and installation diagram
●install
1.35mmstandardDINRail card installation. Please pay attention to the stability and firmness of the card position during installation.
2.Install vertically as much as possible to facilitate heat dissipation inside the instrument.
●Typical applications
1. Suitable for isolating and converting on-site signal inputs: one input and two outputs of the signal.
2. Suitable for devices connected to the site: two-wire or three wire non intelligent transmitters, active current signals.
3. The area where the on-site equipment is located:0District1District2DistrictIIADistrictIIBDistrictIICDistrictT4~T6Dangerous zone.
4. Safety barrier output connection: can be connected to unit combination instruments andDCS/PLCWaiting for the system to be used in conjunction.
●External dimensions
Width (thickness)×tall×Deep=16×116×110(mm)
6、 Terminal wiring diagram
●Terminal wiring: Plug and unplug terminal blocks, connected by self boosting spring type compression. The cross-sectional area of the wire shall not exceed2.5mm2Multiple bundles or single stranded cables.