MOEORW-HVA80-B low-frequency dielectric loss high-voltage generator integrates dielectric loss, capacitance, and insulation resistance measurement, and has both AC and DC withstand voltage testing functions. It has a compact structure and easy operation, with an output voltage of 0-80KV and an accuracy of up to 3%. It is an efficient solution for cable insulation quality testing

Product Details

MOEORW-HVA80 B-ultrasound low-frequency dielectric loss high-voltage generatorProduct Overview

This product is a multifunctional cable testing device that can measure cable dielectric loss, capacitance, and insulation resistance. It has both AC and DC withstand voltage testing functions and can generate insulation quality reports.The dielectric loss measurement unit is integrated into the ultra-low frequency booster, with a compact structure, small size, light weight, easy connection, and convenient operation.

MOEORW-HVA80 B-ultrasound low-frequency dielectric loss high-voltage generatortechnical indicators

Output voltage:0-80KV.

experimentfrequency0.1Hz-0.01Hz

Dielectric loss measurementScope:0.01×10-3- 655.35×10-3 For values greater than655.35×10-3ofThe value will be adjusted according to>655.35×10-3hint

Measurement accuracy of dielectric loss:1x10-3

dielectric lossResolution:1x10-4

Capacitance measurement range:0.001MF10MF

capacitanceResolution:0.001MF

Accuracy of capacitance measurement3%

Insulation resistance measurement range:1MΩ-65535MΩ, for values greater than65535MThe value of Ω will be greater than65535MΩ prompt.

Insulation resistance resolution:1MΩ

Measurement accuracy of insulation resistance3%

Voltage accuracy:3%

AC current range:0-20mA

AC current resolution:0.1mA

Accuracy of AC current:3%

DC current range:0-2000MA

DC current resolution:1MA

DC current accuracy:3%

RS232(orUSB)communication interface