E-mail
info@eco-mind.cn
-
Phone
13910687836
-
Address
1st Floor, Building 2, Linda Technology Incubator, 11-2 Linda North Road, Haidian District, Beijing
Beijing Lico Huize Technology Co., Ltd
info@eco-mind.cn
13910687836
1st Floor, Building 2, Linda Technology Incubator, 11-2 Linda North Road, Haidian District, Beijing
MGA series high-precision greenhouse gas analyzerBased on mid infrared laser absorption spectroscopy technology and using quantum cascade lasers as light sources, the concentration of all gas components is directly measured, which has high recognition and accuracy while maximizing measurement sensitivity.
MGA series high-precision greenhouse gas analyzerThe analyzer hasppbtopptLevel of accuracy,Usually not disturbed by other gases. Adopting an intuitive touch screen display, the operation is simple and fast. Suitable for different applications, including monitoring greenhouse gases, environmental air pollution, and flux measurement using vorticity related methods.
Product Highlights
lmostSimultaneous measurement10Types of gases: methane, carbon monoxide, carbon dioxide, sulfur dioxide, ammonia, nitrous oxide, nitric oxide, nitrogen dioxide, water vapor, ozone, carbonyl sulfide, formaldehyde, and nitrous acid.
lDirectly measure all gas components (including nitrogen dioxide)
lHigh precision monitoring of environmental air quality and low concentration greenhouse gases
lHigher time resolution(1 Hzor10 Hz)Suitable for laboratory, field, and mobile measurements (aircraft, vehicles, ships, ground stations)
Multi domain applications
Øatmospheric science
uContinuous online monitoring of various components such as greenhouse gases and environmental air pollution gases
uAlmost no maintenance required
uDirect and accurate measurement
Øbiosphere
u可野外部署
uSupport low flow gas measurement
uNot disturbed by other gases
ØVorticity correlation method
u支持野外部署
uHigh time resolution(10Hz)
ØMobile measurement
uDurable and compact
useismic design
ulow power consumption
uMulti in one laboratory
measurement parameters
gas |
About10- GP |
About5 - GHG |
About3- GHG |
||||||
C1 |
C2 |
C3 |
C4 |
C1 |
C1 |
C2 |
C3 |
||
|
Wen room qi body |
H2O |
√ |
√ |
√ |
√ |
√ |
√ |
√ |
√ |
CO |
√ |
√ |
√ |
√ |
√ |
- |
√ |
- |
|
CO2 |
√ |
√ |
√ |
√ |
√ |
- |
- |
√ |
|
N2O |
√ |
√ |
√ |
- |
√ |
√ |
√ |
- |
|
CH4 |
√ |
√ |
- |
√ |
√ |
√ |
- |
- |
|
|
filth dye sex qi body |
NH3 |
√ |
√ |
√ |
√ |
- |
- |
- |
- |
NO |
√ |
√ |
√ |
√ |
- |
- |
- |
- |
|
NO2 |
√ |
√ |
√ |
√ |
- |
- |
- |
- |
|
O3 |
√ |
√ |
√ |
√ |
- |
- |
- |
- |
|
OCS |
- |
√ |
√ |
√ |
- |
- |
- |
- |
|
SO2 |
√ |
- |
- |
√ |
- |
- |
- |
- |
|
Home |
- |
- |
√ |
- |
- |
- |
- |
- |
|
Technical Specifications
gas |
About10- GP |
About5-GHG |
About3- GHG |
Maximum drift amount* (24Hour) |
Specification Range |
Measurement range(ppm) |
|
precision@1second/ less than200second |
precision@1second/ less than200second |
precision@1second/ less than200second |
||||
CH4(ppb) |
1 (0.2) |
1 (0.2) |
0.3 (0.1) |
5 |
1´000 - 3´000 |
0 - 200 |
CO(ppb) |
0.4 (0.1) |
0.4 (0.1) |
0.1 (0.05) |
1 |
1´000 - 3´000 |
0 - 20 |
CO2**(ppm) |
0.5 (0.05)** |
0.5 (0.05) |
0.5 (0.05) |
1 |
300 - 500 |
0 - 8´000 |
SO2(ppb) |
2 (0.2) |
- |
- |
5 |
0 - 300 |
0 - 150 |
NH3(ppb) |
0.1 (0.02) |
- |
- |
1 |
0 - 50 |
0 - 15 |
N2O(ppb) |
0.5 (0.05) |
0.2 (0.07) |
0.03 (0.01)** |
2 |
300 - 400 |
0 - 20 |
NO(ppb) |
0.8 (0.1) |
- |
- |
2 |
0 - 400 |
0 - 100 |
NO2(ppb) |
0.4 (0.04) |
- |
- |
1 |
0 - 200 |
0 - 40 |
H2O(ppb) |
20 (2) |
30 (5) |
10 (5)** |
120 |
0 - 30´000 |
0 - 100´000 |
O3(ppb) |
1 (0.2) |
- |
- |
10 |
0 - 300 |
0 - 300 |
OCS(ppb) |
0.05 (0.01) |
- |
- |
2 |
0 - 100 |
0 - 2 |
HONO (ppb) |
2 (0.4) |
- |
- |
10 |
0 - 300 |
0 - 5 |
parameter |
1 Hz |
10Hz |
ambient temperature |
15 - 30 °C |
|
environmenthumidity |
< 90% RH,No condensation |
|
Sample pressure |
700 - 1050 mbar |
|
Sample flow rate |
0.5-1.5 slpm |
15slpm |
Sample entrance accessories |
6 mm Swagelokjoint |
12 mm Swagelokjoint |
size |
W48 × H18 × D70 cm |
|
Required attachments |
Coolers, vacuum pumps |
|
weight |
20 kg(analyzer)11 kg(Cooler)9 kg(Vacuum pump) |
20 kg(analyzer)11 kg(Cooler)24 kg(Vacuum pump) |
power |
110–240 VAC / 50–60 Hz;<100 W(Analyzer), <210/300 W (Coolers and vacuum pumps) |
110–240 VAC / 50–60 Hz;<100 W(Analyzer), <450 W (Coolers and vacuum pumps) |
Installation method |
19”Rack installation or desktop installation |
|
Digital port |
RS232(Data output)USBEthernet |
|
connectivity |
The main functions of the instrument support remote access and control. It includes a personal computer for running instrument software. If network access permission is provided,All functions of the instrument can be accessed through remote control software. |
|
Electrical and laser safety |
haveCEsignEN IEC 61326-1: 2021TheEN IEC 61000-3-2: 2019TheEN 61000-3-3:2013/A2 :2021TheEN 61010-1:2010/ Al:2019/AC:2019TheEN 60825-1:2014/ All:2021/AC:2022TheEN IEC 63000:2018 |
|