LK-1760In situ imaging of rhizosphere enzyme activitysystem
LK-1760In situ imaging of rhizosphere enzyme activitysystemBased on the principle of fluorescence quenching generated by the reaction between fluorescently labeled substrates and soil enzymes,Being able to visualize and analyze enzyme activity in rhizosphere soil without damaging the soil and roots, in order to gain a deeper understanding of soil-root system-The interactions between microorganisms and the functions of soil enzymes in ecosystems provide powerful tools.
Main Features
lin situ detection:Directly detecting enzyme activity in soil and root environment to avoid sampling errors
lvisual analysis:Intuitively display enzyme activity distribution through fluorescent signals, easy to understand and analyze
lhigh sensitivity:Can detect low enzyme activity and capture subtle changes
lnon-destructive:Protect soil and root integrity, reduce ecological damage
lIntelligent image processing software:It is possible to obtain the average enzyme activity and enzyme activity intensity distribution of soil profiles, visualize the enzyme activity distribution, and quantify the relationship between enzyme activity and root distance.
lwidely used:Not only can it be used to study the influence of plant roots on soil enzyme activity, but it can also be used in multiple fields such as monitoring environmental pollution, soil improvement, crop breeding, etc
Technical Specifications
lMeasurable types:β -Glucosidase, cellulase, xylanase, chitinase, phosphatasewait
lbecomeLike a carrier:Polyamide filter membrane
lFilter membrane pore size:0.45um
lFilter membrane size:200mm*200mm(Customizable)
lFluorescent labeled substrate
lHatching time:≤60minute
lImaging conditions
Excitation light wavelength:355nmultraviolet
Emission wavelength:460nmblue light
lImaging system:1/1.8'CMOSGigabit Ethernet industrial area array camera;
Maximum frame rate:5.9fps;
Dynamic range:61dB
Signal to Noise Ratio:39dB
Image resolution:2000Ten thousand pixels
lRepetitive error:less than or equal to5%;
lGrayscale value analysis:16 bit
lMain accessories:Excitation light sourceLEDmatrix1Set; Ethernet industrial array camera1One;450nmoptical filter1One; Incubation filter membrane100Zhang; Shooting in the dark box1One; Substrate reagent1Set; Image analysis software1Set.
lImage processing software:It is possible to obtain the average enzyme activity and enzyme activity intensity distribution of soil profiles, visualize the enzyme activity distribution, and quantify the relationship between enzyme activity and root distance.