- Phone
-
Address
806, Building 1, Yinxing Life and Health Technology Park, Pingshan District, Shenzhen
Shenzhen Jinxiao Instrument Equipment Co., Ltd
806, Building 1, Yinxing Life and Health Technology Park, Pingshan District, Shenzhen
MECT Multi Energy CT and Advanced Electronic Density Module Set805940 KitThis kit includes all components from the "Multi Energy CT" kit and the "Advanced Electronic Density" kit, including a 20 centimeter diameter head model (16 centimeters deep), a 40 × 30 centimeter torso ring (16 centimeters deep), a bracket, a wheel box, and all 41 insertion rods included in the separate kit.
Note: If you only have MECT Multi Energy CT phantom or Advanced Electronic Density phantom, you can choose the following upgrade options:
Part number 805941 Crossover Kit adds advanced electronic density functionality to MECT
Part number 805942 Crossover Kit adds MECT functionality for advanced electronic density
Gammex 1472 MECT Multi energy CT phantom comprehensive testing, tissue equivalence
Equipped with 28 types of plugins, representing different sizes and concentrations of iodine, calcium, blood, fat, and other materials of special concern to Multi Spectral CT (MECT)
• Can comprehensively test the performance of multi spectral CT scanners
Expanded the range of high-energy iodine and high-energy calcium
Dual energy CT imaging can provide quantitative results, therefore regular quality control is required. The quality control scheme for single energy CT is obviously not sufficient for dual energy CT. Multi functional CTphants can provide rigorous testing conditions to ensure system performance meets the required standards.
Multi spectral CT scanners have improved clinical differentiation capabilities, such as the ability to distinguish between blood and calcified lesions, as well as calcified lesions and iodinated contrast agents. They can also generate virtual single energy spectrum images for clinical evaluation. However, whether these advantages can be achieved depends not only on the device itself, but also on the scanning scheme adopted.
The multi spectral CT simulator from Sun Nuclear can reliably evaluate the performance of scanners.
• Use solid rods representing iodine, calcium, blood, fat, and other substances to test material identification ability
• Use solid rods representing substances such as iodine, calcium, blood, fat, etc
Ensure the effectiveness of clinical protocols for multi spectral analysis
• Verify the quantitative accuracy of multi spectral scanning
Compare the consistency and stability between different scanners
• Check for artifacts within the expanded field of view
• Supports testing in two configurations: head (20 cm) and torso (40 cm x 30 cm)
Automated analysis achieved through specialized and efficient rod marking technology
Gammex Advanced Electronic Density Model accurately converts CT values into HU values or electron densities, facilitating the transition from diagnosis to electron density
It plays an important role in the process of specific treatment plans. With the help of advanced electron density models, ICRU-44's matching tissue equivalence, automation functions, and intelligent design work together to eliminate uncertainty in the energy conversion process.
Our material manufacturing meets medical standards for human tissue density.
Using RapidCHECK ™ To achieve workflow automation, we obtained three specialized and efficient rod-shaped markers that can uniquely identify each material during CT scanning. This enables the automation of CT to density analysis, saving valuable time and reducing the risk of errors.
Using RapidCHECK ™ The software automatically searches and identifies the material of each rod-shaped marker, simplifying the calibration process from CT to electron density.
Get results instantly. Load data. Obtain analysis. Print the report. Track changes over time. If a problem is detected, it is easy to review previous scans, analyze trends, and investigate abnormal results.
Characteristics and advantages of Gammex advanced electron density module in the United States
• Size expansion
-Can extend up and down by 16.5 centimeters
-Using a rod with a total length of 16.5 centimeters instead of just 5 centimeters
-Flat spherical design, width 40cm, height 30cm
-Detachable 20cm head component
-When paired with an optional extension board, the length can reach 26.5 centimeters
• Mature technology
-Adopting zero HU CT Solid Water ® HE
-Biomimetic tissue material, compliant with ICRU-44 and ICRP specifications
MECT Multi Energy CT and Advanced Electronic Density Module Set805940 KitActual photos taken upon arrival

Note: GAMMEX has been acquired by Sun Nuclear and is part of the same group.
Our company has officially become the direct agent of Sun Nuclear/CSIS diagnostic modules in the Chinese market since January 2022. In addition, we also specialize in purchasing molds from other brands, including Phantom Lab, ACR, JJ&A, Phantom X, QRM, QMRI, CAE, Artinis, QUART, and more. Welcome to inquire.
Our company has a procurement department in the United States and a sales center located in Shenzhen, Guangdong Province. We source our European brand instruments, molds, and industrial control products from factories in the United States and look for Jinxiao!