M30 Inductive Proximity Switch
M30 Inductive Proximity Switch |
|
|
| DC three wire/DC-3Wire |
| Proximity switch model |
NPN NO NPN NC
|
3LR30-L10N1 |
3LR30-P15N1 |
| 3LR30-L10N2 |
3LR30-P15N2 |
PNP NO PNP NC |
3LR30-L10P1 |
3LR30-P15P1 |
| 3LR30-L10P2 |
3LR30-P15P2 |
| Installation method |
flush type |
Protruding type |
| outline dimension |
Φ30*50 |
Φ30*50 |
| Detection distance (max) |
10mm±10% |
15mm±10% |
| Stable detection distance |
0~8mm |
0~12mm |
| movement differential |
Within ± 10% of the working distance (using standard detection objects) |
| repeatability |
≤5% |
| Detected object |
Magnetic metal (non-magnetic metal reduces detection distance) |
| Standard test substance |
Iron 30 × 30 × 1mm |
| response frequency |
200Hz |
| Power supply voltage (voltage range) |
DC 12V-24V (DC10-30V) pulse (p-p) below 10% |
| Consumption current |
Below 12mA |
| control output |
Maximum 200mA (at 24V) |
| Residual Voltage |
≤ 1V (when the wire is 2 meters long) |
| Display light |
Action display light (red LED) |
| Output form |
Type 1: NO Type 2: NC |
| protection circuit |
Reverse connection protection, surge absorption, short circuit (overcurrent) protection |
| Connection method |
3-core wire with a cross-sectional area of 0.3mm ², lead out type (standard wire length of 2m or customized according to requirements), connector type |
| DC two-wire/DC-2Wire |
| Proximity switch model |
2LR30-L10NO |
2LR30-P15NO |
| outline dimension |
Φ30*50 |
Φ30*50 |
| Installation method |
flush type |
Protruding type |
| Maximum detection distance |
10mm±10% |
15mm±10% |
| Stable detection distance |
0~8mm |
0~12mm |
| movement differential |
Within ± 10% of the working distance (using standard detection objects) |
| repeatability |
≤5% |
| Detected object |
Magnetic metal (non-magnetic metal reduces detection distance) |
| Standard test substance |
Iron 30 × 30 × 1mm |
| response frequency |
200Hz |
| Power supply voltage (voltage range) |
DC12V-24V (DC10-30V) pulse (p-p) below 10% |
| Leakage current |
Below 1mA |
| control output |
Switch capacity |
3-100mA |
| residual voltage |
≤ 5V (100mA. When the wire is 2M) |
| Display light |
Action display light (red LED) |
| protection circuit |
Short circuit protection, surge absorption |
| Connection method |
2-core wire with a cross-sectional area of 0.3mm ², lead out type (standard wire length of 2m or customized according to requirements), connector type |
| |
|