| M18 inductive proximity switch/proximity sensor
|
| DC three wire/DC-3Wire |
| model |
NPN NO NPN NC |
3LR18-L6N1 |
3LR18-P9N1 |
| 3LR18-L6N2 |
3LR18-P9N2 |
PNP NO PNP NC |
3LR18-L6P1 |
3LR18-P9P1 |
| 3LR18-L6P2 |
3LR18-P9P2 |
|
Installation method
|
flush type |
Protruding type |
|
outline dimension
|
Φ18*48 |
Φ18*48 |
|
Maximum detection distance
|
6mm±10% |
9mm±10% |
|
Stable detection distance
|
0~4.8mm |
0~7mm |
|
movement differential
|
Within ± 10% of the working distance (using standard detection objects)
|
|
repeatability
|
≤1%
|
|
Detected object
|
Magnetic metal (non-magnetic metal reduces detection distance)
|
|
Standard test substance
|
Iron 18 × 18 × 1mm
|
|
response frequency
|
400Hz
|
350Hz
|
|
Power supply voltage (voltage range)
|
DC12V-24V (DC6-30V) pulse (p-p) below 10%
|
|
Consumption current
|
Below 10mA
|
|
control output
|
Maximum 100mA (30V)≤ 1V (when the wire is 2 meters long)
|
|
temperature range
|
-35~+70 ℃, with a variation of ± 10 ℃, detection distance≤±5%
|
|
Display light
|
360 ° visible action display light (red LED)
|
|
Output form
|
Type 1: NO Type 2: NC,
|
|
protection circuit
|
Reverse connection protection, surge absorption, load short circuit protection
|
|
Connection method
|
3-core wire with a cross-sectional area of 0.3mm ², lead out type (standard wire length of 2m or more)Customize according to requirements)
|
| DC two-wire/DC-2Wire |
| model |
2LR18-L6NO |
2LR18-P9NO |
| outline dimension |
Φ18*48 |
Φ18*48 |
| Installation method |
flush type |
Protruding type |
| Maximum detection distance |
6mm±10% |
9mm±10% |
| Stable detection distance |
0~4.8mm |
0~7mm |
| movement differential |
Within ± 10% of the working distance (using standard detection objects) |
| repeatability |
≤1% |
| Detected object |
Magnetic metal (non-magnetic metal reduces detection distance) |
| Standard test substance |
Iron 18 × 18 × 1mm |
| response frequency |
300Hz |
| Power supply voltage (voltage range) |
DC12V-24V (DC6-30V) pulse (p-p) below 10% |
| Leakage current |
Below 1mA |
| control output |
Switch capacity |
3-100mA |
| residual voltage |
≤ 3.5V (100mA. When the wire is 2M) |
| Display light |
360 ° visible action display light (red LED) |
| protection circuit |
Short circuit protection, surge absorption,Temperature range: -35 to+70 ℃, with a variation of ± 10 ℃ and a detection distance≤±5% |
| Connection method |
A 2-core wire with a cross-sectional area of 0.3mm ², with a standard wire length of 2m orCustomize according to requirements) |
| Two line communication/DC-2Wire |
| model |
NO type
|
2LR18-L6AO
|
2LR18-P9AO
|
|
NC type
|
2LR18-L6AC
|
2LR18-P9AC
|
|
Maximum detection distance
|
6mm±10%
|
9mm±10%
|
|
Stable detection distance
|
0~4.8mm
|
0~7.2mm
|
|
movement differential
|
Less than 10% of the working distance (using standard detection objects)
|
|
Detected object
|
Iron and magnetic metals (the detection distance may be reduced for non-magnetic metals)
|
|
response frequency
|
20Hz
|
|
Power supply voltage (voltage range)
|
AC100V-240V(AC60~250V) 50-60Hz
|
|
Leakage current
|
Less than 2.5mA
|
|
control output
|
3-100mA at AC220V (maximum 200mA)
|
|
Display light
|
360 ° visible action display light (red LED)
|
|
Protection circuit
|
Surge absorption
|
|
Residual Voltage
|
Less than 10V
|
|
ENVIRONMENTAL
|
Usage temperature
|
-35~+70 ℃, during storage: -30~+80 ℃ (without freezing or condensation)
|
|
Use humidity
|
35~85%RH, Storage time: 35-95% RH
|
|
withstanding voltage
|
AC1,000V 1 minute between all connection terminals and the casing
|
|
insulation resistance
|
All connection terminals to the casing, with a resistance of over 50M Ω, based on a DC500V megohmmeter
|
|
Temperature
|
Temperature range: -35 to+70 ℃, with a variation of ± 10 ℃ and a detection distance≤±5%
|
|
Protect the structure
|
IEC specification IP67
|
|
Connection method
|
0.3mm ² 2-core PVC wire, standard length 2m(customizable)
|
|
material
|
Shell: brass (nickel plated), detection unit: PC, indicator light unit: PC
|
|
attachment
|
User manual, 2 nuts, 2 toothed lock washers
|