RP-8 lubricating oil foam property tester is applicable to GB/T12579 and ASTM D892 Determination of foam Property of Lubricating Oils. It is used to determine the tendency and stability of fire-resistant oil, lubricating oil, gear oil, hydraulic oil and other oil products to generate foam The instrument consists of a constant temperature water bath, temperature control, time control, gas diffusion head, air source, gas flow control, and other components. Adopting microcomputer intelligent adjustment and four-way automatic timing for temperature timing control. It can be widely used in departments such as power, petroleum, chemical, railway, aviation, commercial inspection, and scientific research.
RP-8Lubricating oil foam characteristic testerIt is applicable to GB/T12579 and ASTM D892 Determination of foam Characteristics of Lubricating Oils, which is used to determine the tendency and stability of fire-resistant oil, lubricating oil, gear oil, hydraulic oil and other oil products to generate foam The instrument consists of a constant temperature water bath, temperature control, time control, gas diffusion head, air source, gas flow control, and other components. Adopting microcomputer intelligent adjustment and four-way automatic timing for temperature timing control. It can be widely used in departments such as power, petroleum, chemical, railway, aviation, commercial inspection, and scientific research.
working principle
At 24 ℃, blow air at a constant flow rate for 5 minutes. At the end of each cycle, measure the volume of foam in the sample. Take the second sample and conduct the test at 93.5 ℃. When the foam disappears, repeat the test at 24 ℃.
Main Features
High precision AD, more accurate measurement
● Adopting microcomputer control and LCD display
Imported silent air pump with low noise
Adjustable four-way flow, high and low temperature controlled bathtub
PID temperature control tuning technology for more precise temperature control
When the room temperature is above 24 ° C, an input type refrigerator can be optionally selected
technical indicators
Temperature control range: 0-100 ℃ (when the room temperature is above 24 ℃, an input type refrigerator needs to be selected)
24 ℃ (low temperature tank) 93.5 ℃ (high temperature tank)
Temperature control accuracy: ± 0.3 ℃
Timing method: automatic timing, accuracy ± 1S
Timing device: 0-99.99 hours
Flow meter: equipped with regulating valve 16-160 mL/min
Air source: self-contained air source, 3L/min
Flow control: 16-160mL/min float flowmeter, adjustable
Gas flow rate: 94mL/min ± 5mL/min
Diffusion head air permeability: 3000-6000ml/min at 2.4kpa (250mmHg)
Environmental temperature: 5 ℃~40 ℃
Environmental humidity: ≤ 85% RH (no condensation)
Portable refrigerator power: 200W (optional)
Power supply voltage: AC220V ± 10% 50Hz ± 10%
Host size: 320mm × 390mm × 550mm
Weight: 35kg