Welcome Customer !

Membership

Help

Kovel (China) Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Kovel (China) Co., Ltd

  • E-mail

    2851086852@qq.com

  • Phone

    15021551716

  • Address

    Room 111, 1st Floor, Building 13, No. 89 Huguang East Road, Minhang District, Shanghai

Contact Now

Low temperature liquid mass flowmeter _ Koweiler

NegotiableUpdate on 12/16
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Low temperature liquid mass flowmeter _ Koweiler: The thermal gas mass flowmeter is designed based on the principle of thermal diffusion, and the instrument uses the constant temperature difference method to accurately measure gases. It has the advantages of small size, high degree of digitization, easy installation, and accurate measurement.
Product Details

Low temperature liquid mass flowmeter _ Koweiler

principle&structure

'The thermal gas mass flowmeter is designed based on the principle of thermal diffusion, and uses the constant temperature difference method to accurately measure gases. It has the advantages of small size, high degree of digitization, easy installation, and accurate measurement.

The sensor part consists of two reference level platinum resistance temperature sensors. When the instrument is working, one sensor continuously measures the temperature of the mediumT1The other sensor self heats up to a temperature higher than the medium temperatureT2It is used to sense fluid flow velocity and is called a velocity sensor. This temperatureΔT=T2-T1T2>T1When fluid flows through, gas molecules collide with the sensor andT2The heat is carried away, makingT2If the temperature drops, in order toΔTTo remain unchanged, we need to improveT2The power supply current, the gas flow rate, and the heat carried away are faster, and there is a fixed functional relationship between the gas flow rate and the increased heat.'

formula1image.png

among whichρg --Fluid specific gravity (related to density)

V —flow velocity

K —Balance coefficient

Q —Heating capacity (related to specific heat and structure)

ΔT —temperature difference

Due to the fact that the temperature of the sensor is always automatically and consistently higher than the temperature of the medium (environment)30℃Left and right, so the thermal gas flowmeter does not require temperature compensation in principle.

The applicable temperature range of the thermal gas mass flowmeter is-40-220℃.

1)The specific gravity and density of the fluid in the formula are related

formula2image.png

among whichρ_g —Medium density under working condition volume(kg/m3'From the formula1and2It can be concluded that the functional relationship between flow rate and operating pressure, gas density, and operating temperature has been determined.

The constant temperature differential thermal gas mass flowmeter is not affected by temperature and pressure, and does not require correction of pressure and temperature.

'

ρn —Medium density under standard conditions(101.325 KpaThe20℃) (kg/m3

P —Operating pressure(KPa

T —Operating temperature(

image.png

Low temperature liquid mass flowmeter _ Koweiler

application

All inert gases and clean gases without condensation, combustible gases such as methane, propane, hydrogen, and biogas;

and316LStainless steel compatible with corrosive gases, etc

FGMThe series thermal gas mass flowmeter is a new type of flow meter that can conveniently and accurately detect the mass flow of air, nitrogen, hydrogen, oxygen, chlorine, natural gas, flue gas, biogas, and other gases flowing in pipelines without temperature and pressure compensation. It can be widely applied in the process control and gas flow measurement of petroleum, chemical, metallurgical, power, water treatment, papermaking, food, medicine, cement, textile and various production and research units for gas production and consumption.

Typical application scenarios

*Measurement of Gas Flow in Steel and Coking Plants

*Gas flow measurement in the production process of cement, cigarettes, and glass factories

*Boiler air flow and secondary air volume measurement

*Compressed air flow measurement

*Measurement of Smoke Flow from Chimney Emissions

*Measurement of flow rates for various mixed gases such as natural gas, coal gas, liquefied gas, torch gas, argon gas, carbon dioxide, etc

*Measurement of aeration flow rate in water treatment

*Measurement of Gas Flow in Steel and Coking Plants

*Measurement of primary air, secondary air, cold air return air volume in power plants

*High pressure low flow hydrogen gas for generator cooling

*Measurement of Torch Gas in Chemical Plants

*Top blown argon gas in steel plant

feature

Without pressure and temperature compensation, directly measure the mass flow rate of gas.

High sensitivity, especially suitable for flow measurement of large pipe diameters and low flow rates.

High repeatability, high reliability, high stability, and high precision.

The pressure loss is extremely small and almost negligible.

Wide range of measurement: maximum achievable100 :1The above.

Diverse structures, flexible installation, easy loading and unloading, and convenient use.

Explosion proof and corrosion-resistant design, suitable for harsh working conditions and corrosive environments.

On site rotation angle of display screen0~270°

Technical Specifications


Nominal Diameter(mm):

Pipeline type:DN10DN125

Insertion type:DN100DN2000(Customization of special pipelines)

Measurement range:

Refer to the detailed flow parameter table

essence indeed Degree:

Pipeline type:±1.0%FS±2%FS

Insertion type:±1.5%FS±2.5%FS

heavy again Sex:

±0.25%FS

Response time:

2Reaching the final value in seconds63%(a time constant)

spirit Min Degree:

< 0.05 m/s



Power supply:

24VDCAC220V

Total power consumption:

less than20W

Output signal:

Current output photoelectric isolation 420mA0500KΩ

RS485(Modbusagreement)TheHART

Alarm signal:1-2 relay normally open contact signals

24VDC,10A; 220VAC,10A



Display content:

Mass flow rate, standard condition volume flow rate

Instantaneous flow rate, cumulative flow rate, medium flow rate, cumulative operating time

Flow percentage (instantaneous flow)6 digits, cumulative traffic of 10 digits)

Instantaneous flow unit:

Nm3/h,Nm3/min,

L/h,L/min,t/h,t/min,

kg/min,kg/h,

Record storage query:

Diary record, monthly record, annual record

Instrument shell material:

cast aluminum&glass

Sensor material:

stainless steel1.4301(304)


stainless steel1.4435(316L)

Applicable pipeline materials:

carbon steelStainless steel, plastic, etc

Protection level:

IP65

Explosion proof grade:

ExdCT26(Certification in progress)



work pressure

Pipeline type:40bar


Insertion type:25bar

Connection method:

Flanges and threaded connections can be used between flow meters and piping

Required length of straight pipe section:

upstream5DN, downstream3DN

Flow direction:

Positive, negative, net traffic



Execution standard:

DIN EN 1092-1-2002

Sales Usage Standard (Order Remarks)

LVD 2006/95/EC&EMC 2004/108/EC

EN 61326-1:2006Radiation standards(BS EN50081-1)

EN 61326-1:2006Anti-interference standard(BS EN50082-1)

EN 61010-1:2001Equipment safety requirements: General requirements



Fluid temperature:

-40+120 -40+220

Ambient temperature

-10+55

ambient humidity:

90%r.hnon-condensing

Size chart

FGM10Online pipeline type

image.png

Unitmm

path

Core size

Flange type size

Thread type size

DN

L

D(Outer diameter of flange)

Number of bolt holes

bolt hole diameter

bolt specification

center-to-center distance

Cflange thickness

external thread

15

125

115

4

14

M12

65

14

G1

20

125

115

4

14

M12

75

16

G1

25

125

115

4

14

M12

85

16

G1 1/4

32

125

115

4

18

M16

100

18

G1 1/2

40

135

150

4

18

M16

110

18

G2

50

140

165

4

18

M16

125

20

G2 1/2

65

140

165

4

18

M16

145

20

/

80

194

200

8

18

M16

160

20

/

100

230

220

8

18

M16

180

22

/

FGM20Card sleeve thread insertion typeReference flow range

pipe diameter(DN)

flow range(Nm3/h)

pipe diameter(DN)

flow range(Nm3/h)

pipe diameter(DN)

flow range(Nm3/h)

10

0.1217

150

303800

900

1000140000

15

0.340

200

506800

1000

1200170000

20

0.570

250

10010000

1200

2000240000

25

0.7100

300

15015000

1400

3000330000

32

1.2170

350

20020000

1600

3500430000

40

2270

400

25027000

1800

4000550000

50

3420

450

30035000

2000

5000680000

65

5720

500

35042000

2200

6000820000

80

81100

600

50061000

2400

7000976000

100

121700

700

60083000

2600

80001146000

125

202600

800

800100000

2800

110001526000

Note: The above flow rates are for pipeline installation methods, where the medium is air, nitrogen, or other gases that are close to ideal. For other gases or those that do not belong to the diameter listed above, please contact the sales engineer.

For plug-in flow meters, their measurement range is generally divided according to the speed mode as follows:

a)0~0.5m/s

b) 0~1.0 m/s

c)0~2.5 m/s(recommend)

d) 0~5.0 m/s(recommend)

e)0~10.0 m/s(recommend)

f) 0~25.0 m/s(recommend)

g) 0~50.0 m/s

h) 0~60.0 m/s

Selection Table

FGM10-

Thermal gas mass flowmeter (online pipeline type)

FGM20-

Thermal gas mass flowmeter (insert type with card sleeve thread), with external thread)

FGM30-

Thermal gas mass flowmeter (online installation plug-in type)Low voltage online plugging and unplugging, including ball valves and packing glands

FGM40-

Thermal gas mass flowmeter (flange insertion type)


structural form


Local header


Remote header, indicate cable length in parentheses


Nominal Diameter


DN10~DN125(Online pipeline type)


DN100~DN500(Small caliber insertion type)


DN600~DN2000(Large caliber insertion type)


power supply


24VDC±10%DC power supply


100~240VACAC power supply


output signal


No signal output


4~20mAcurrent signal


HARTProtocol type


display form


No display


Local digital jump display quality flow (instantaneous, cumulative, flow rate, flow percentage)


accuracy class


±1.5%FS


±1.5%FS


±2.0%FS


Agreed accuracy (or fine calibration interval)


(Optional accessories)


No accessories


Gas rectifier

FGM-








← Selection Example


Koweiler (China) Automation Co., Ltd. is located in Shanghai and specializes in steam flow meters, sewage flow meters, electromagnetic flow meters, vortex flow meters, turbine flow meters, gear flow meters, ultrasonic flow meters, pressure transmitters, pressure controllers, pressure switches, differential pressure transmitters, differential pressure switches, temperature transmitters, temperature controllers, temperature switches, and other products. On the basis of adhering to technological innovation, the company attaches great importance to quality management, continuously improves service levels, and achieves the healthy development of the company's business. We actively participate in promotion and industry exchange activities. In the long-term development process, our company has established long-term and good partnerships with many large domestic manufacturers based on our excellent product quality, good product performance, and technological advantages. Our service tenet is honesty, fairness, trustworthiness, reasonable price, equality and mutual benefit. With strong economic strength and adherence to the principle of honesty, the company has won the trust of many customers and gained a good reputation in the industry.