Low temperature air-cooled chiller

NegotiableUpdate on 11/10
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Low temperature air-cooled chiller, abbreviated as low-temperature chiller. Due to its liquid outlet temperature ranging from 0 to 80 degrees and cooling method being fan cooling, it is also known as air-cooled low-temperature chiller unit.

Product Details

Low temperature air-cooled chiller, abbreviated as low-temperature chiller. Due to its liquid outlet temperature ranging from 0 to 80 degrees and cooling method being fan cooling, it is also known as air-cooled low-temperature chiller unit.



SJ-20AD
refrigeration power KW/hr(50Hz) 22 (-25 discharge condition)
input power V 3∮ 380V~50HZ
operating current A 42
refrigerant model R404A
charge amount
(kg)
9
Total input power KW 13
Number of compressors 2
cooling air volume m3/h 20000
pump power KW 1.5
Flow rate of chilled water m3/hr 4
出口管径 MM 50
Overall dimensions L(mm) 1955
W(mm) 940
H(mm) 1960
Total weight kg 720
For more model parameters, please click to enter
Low temperature chillers typically use semi enclosed piston compressors, which have the following advantages:
1. The piston compressor has a wide range of applicable pressures and can be designed for low pressure, medium pressure, high pressure, and ultra-high pressure. Moreover, at equal speeds, when the exhaust pressure fluctuates, the displacement of the piston compressor remains basically unchanged.
2. The compression efficiency is high, and the process of compressing gas with a piston compressor belongs to a closed system, resulting in high compression efficiency.
3. Strong adaptability, piston compressors have a wide range of displacement, and the impact of gas density on compressor performance is not as significant as that of speed compressors, making them more suitable for low-temperature operating units.

Requirements for the use of low-temperature air-cooled chillers

1. According to different usage temperatures, there are different requirements for cooling media. It is recommended to use ethylene glycol solution from 0 to 40; -Low temperature thermal oil is recommended for temperatures below 60 degrees, and flammable liquids such as alcohol are not recommended.
2. The installation of low-temperature chiller units should be as close as possible to the equipment in use, because the farther away the distance, the greater the pump head and the higher the motor power, which increases the load on the unit. The pipeline must be insulated and protected to minimize the loss of cooling capacity.



Q: Can this low-temperature chiller use a 3-phase 220V 60Hz power supply?
Answer: Yes, the compressor motor can support a wide range of power supply standards and may also be controlled by adjusting the input/output power through a frequency converter.