Concrete mixing plant screw chiller, abbreviated as mixing plant chiller. Mixing plant chiller is a type of equipment specifically designed for mixing engineering concrete. In the construction of highway bridges and elevated bridges, the requirements for concrete are very high. However, when the concrete is poured and hardened, a large amount of hydration heat is generated during the cement hydration process. Due to the large volume of concrete, a large amount of hydration heat is easily accumulated inside the concrete and cannot be dissipated, resulting in a sharp increase in internal temperature. However, the heat dissipation on the surface of concrete is very fast, which causes a large temperature difference between the inside and outside of the concrete. This temperature difference will result in different degrees of thermal expansion and contraction between the inside and outside, causing a certain tensile stress on the surface of the concrete. So the use of low-temperature water for mixing concrete needs to solve this problem, so that the concrete can have higher hardness and strength after structural hardening.
Concrete mixing plant screw chiller, abbreviated as mixing plant chiller. Mixing plant chiller is a type of equipment specifically designed for mixing engineering concrete. In the construction of highway bridges and elevated bridges, the requirements for concrete are very high. However, when the concrete is poured and hardened, a large amount of hydration heat is generated during the cement hydration process. Due to the large volume of concrete, a large amount of hydration heat is easily accumulated inside the concrete and cannot be dissipated, resulting in a sharp increase in internal temperature. However, the heat dissipation on the surface of concrete is very fast, which causes a large temperature difference between the inside and outside of the concrete. This temperature difference will result in different degrees of thermal expansion and contraction between the inside and outside, causing a certain tensile stress on the surface of the concrete. So the use of low-temperature water for mixing concrete needs to solve this problem, so that the concrete can have higher hardness and strength after structural hardening.

| |
SJ-620WD |
| refrigeration power |
kcal/hr(50Hz) |
496822 |
| power supply |
V |
3∮ 380~380V- 50HZ |
| Maximum operating current |
A |
220 |
| refrigerant |
Kind |
R407C、R22、R404 |
| FILLING QUANTIT(kg) |
110 |
| compressor power |
KW |
130 |
| Number of compressors |
|
1 |
| Cooling water flow rate |
m3/h |
140 |
| water pump |
KW |
no |
| Flow rate of chilled water |
m3/hr |
100 |
| Standard inlet and outlet pipe diameters |
MM |
150 |
| Design dimensions |
L(mm) |
3070 |
| W(mm) |
1100 |
| H(mm) |
2000 |
| weight |
kg |
2730 |
The air-cooled screw chiller at the mixing plant can provide cooling water from 0-15 degrees. Calculated based on the inlet water temperature of 30 degrees for tap water and the required temperature for mixing cooling water of 10 degrees, this SJ-230AS screw chiller can supply 10T of 10 degree cold water per hour.
The unit is automatically controlled according to the set temperature, and the cold water supply pump and make-up pump can be manually controlled or timed controlled.
Information table of supporting equipment required for air-cooled screw chiller in mixing plant:
1. Water storage tank: The water tank is an insulated water tank, and its capacity is customized according to the amount of cold water required for each mixing.
2. Cold water supply pump: According to a water supply of 10T per hour, a 20-30 cubic meter flow pump can be selected.
3. Water replenishment pump: It is required to be able to quickly replenish water, and the flow rate should be the same as that of the cold water pump. After supplying the chiller, water replenishment should be carried out in the south.
4. Power supply: 3 * 50+1 * 25mm2
Q: Can you provide a certificate of origin for this chiller unit used abroad?