Low speed large capacity centrifuge is suitable for separating different liquids in biochemistry, radioimmunoassay laboratories, pharmaceuticals, biopharmaceuticals, and other fields.
The low-speed large capacity centrifuge is directly driven by a motor, with special shock absorbers for vibration reduction. The rotor is precision cast from high-strength materials, making it easy to install and remove. Intelligent control, full digital display of speed and time, precise control. A rotor can replace multiple pipe racks to meet the needs of different users.
Instrument features:
The XZ-6G low-speed large capacity centrifuge is suitable for separating different liquids in biochemistry, radioimmunoassay laboratories, pharmaceuticals, biopharmaceuticals, and other fields.
Technical parameters of XZ-6G desktop low-speed large capacity centrifuge:

XZ-6G installation program:
1. The tabletop is solid and flat to prevent vibration or instrument movement during operation of the XZ-6G low-speed large capacity centrifuge.
2. The XZ-6G low-speed large capacity centrifuge power supply has an independent ground wire, and it is strictly prohibited to share the neutral wire with the ground wire to prevent electric shock and injury.
3. There should be no corrosive gases or electromagnetic field interference around the XZ-6G low-speed large capacity centrifuge to prevent premature failure of the instrument's outer protective layer and interference with electrical components.
4. The XZ-6G low-speed large capacity centrifuge is placed horizontally to ensure that the four rubber machine feet are evenly stressed.
XZ-6G low-speed large capacity centrifuge operating procedure:
1. Turn on the power supply of the low-speed large capacity centrifuge, and the centrifuge door cover will automatically open; The centrifuge tubes in the centrifugal sampling area are symmetrically placed in the rotor, and each tube of the sample can be visually inspected.
2. Press the selection key, * is the rotor number, press the ▲▼ key, then press the selection key, and press the ▲▼ key to pre select the speed.
3. Same as the pre selection time
4. After selecting your parameters, press the approval button. During operation, the centrifugal force can be directly displayed. Press the centrifugal force button (note: the speed can still be modified during operation), and then press the start button to start working.
When the time reaches zero or the stop button is pressed, the automatic shutdown door cover will automatically open.