Logic analyzer probe
TLP058
Product Overview and Key Features
*Basic function: Expand the FlexChannel input of an oscilloscope into 8 independent digital logic input channels for measuring multiple digital signals simultaneously.
*Core features:
*High bandwidth and sampling rate: With a bandwidth of 500 MHz and a maximum sampling rate of 6.25 GS/s, it is suitable for high-speed digital signal debugging.
*High input impedance: The input resistance is 100 k Ω, and the input capacitance is only * * 3.0 pF * *, which can effectively reduce the load impact on the tested circuit.
*Wide threshold range: The threshold voltage range reaches ± 40 V, which can adapt to a wider range of logic levels.
*High sensitivity: The minimum detectable pulse width is * * 1 ns * *, which can capture very narrow pulses.
Compatible oscilloscope models
TLP058 is designed specifically for Tektronix's MSO series with FlexChannel interface, and is mainly compatible with specific models in the following series:
*5 Series MSO: including MSO54, MSO56, MSO58, MSO58LP.
*6 series MSO: such as MSO64.
*4 Series MSO: Also supports using TLP058 to convert each FlexChannel into 8 digital channels.
Main technical specifications
*Input channel: 8 digital channels
*Input voltage range: maximum 30V
*Minimum input signal swing: 400mV p-p
*Digital to analog trigger offset: 5ns
*Probe length: 1.0 meter
*Working temperature: 0 ° C to+50 ° C
How to use and connect
1. Connect the oscilloscope: Turn the probe locking lever to the "unlocked" position, insert the probe into the FlexChannel connector of the oscilloscope until a "click" sound is heard, and then turn the locking lever back to the "locked" position. At this time, the status indicator light should be * * constantly on green * *.
2. Automatic configuration: After the probe is connected, the oscilloscope usually automatically detects and configures channels.
3. Connect the tested circuit: Use the probe wires and adapter in the accessory kit to connect the probes and ground wires of the 8 channels to the corresponding test points of the tested device.
Usage tips and suggestions
*Automatic recognition: TLP058 is designed to be plug and play, and the oscilloscope can automatically recognize the probe type after connection.
*Signal verification: If the expected signal activity cannot be seen on the digital channel, it is recommended to use an analog probe (such as a standard passive voltage probe) connected to the same test point to verify whether the signal itself is normal.
*Safe operation: To avoid damaging the equipment, it is necessary to first power off the tested circuit before connecting or disconnecting the probe.
In summary, TLP058 is a high-performance logic probe that can expand a single input of Tektronix FlexChannel MSO into 8 digital channels, making it ideal for debugging tasks that require simultaneous observation of multiple digital buses or signals (such as power timing, parallel buses, multi-channel digital IO, etc.)
Logic analyzer probe
TLP058
FlexConnect Logic Probe Instructions These instructions describe the setup, connection, and specific parameters of the TLp058 FlexChanne Universal 8-Channel Logic Probe, which is suitable for Series MSO (MSO54, MSO56, MSO58) instruments.


![]()
![]()
![]()