The lithium battery glove box dew point meter is a small, two-wire loop powered oxygen analysis transmitter with a current fuel cell probe and linear output.
Lithium battery glove box dew point meterProduct Introduction:
The lithium battery glove box dew point meter is a small, two-wire loop powered oxygen analysis transmitter with a current fuel cell probe and linear output.
In addition to the standard stainless steel type, O2X1 also has the following two types:
*It is a low-cost type, and the wet components of the transmitter use Delrin. this kind of
The type is the same as the standard stainless steel type O2X1, using a 1/8 "(3.175 mm) NPTF process connection pipeline,
Applicable to all ranges except for low PPM oxygen content.
*The second method is to cut open the lower manifold to expose the sensor,
Delrin design is suitable for detecting oxygen content in ambient air. This model comes with an aluminum mounting bracket,
O2X1 can be installed at any convenient location on the wall.
Lithium battery glove box dew point meterApplication:
O2X1 oxygen transmitter, suitable for the following industries:
Heat treatment and non oxidative annealing
Gas monomer process inspection rules
Monitoring of pure hydrocarbon gas flow
Protective welding inert gas
Glove work box leak detection
Environmental air monitoring
Power requirements
9~28 VDC loop power supply, high power 0.6 W
Sampling gas flow rate
For electrical classification/certification of process components, it is recommended to use 1.0 SCFH (500 cc/min)
European Standard
Compliant with the EMC Directive 89/336/EEC
On site programmable
measurement range
Ppm level sensor:
-0~10 ppmv O2 (OX-1 or OX-2, only for 316 stainless steel parts)
– 0~100 ppmv O2
– 0~1000 ppmv O2
– 0~10,000 ppmv O2
%Level sensor:
– 0%~1% O2
– 0%~10% O2
– 0%~25% O2
precision
± 1% of the measuring range (at the calibration point)
For the range of 0-10 ppmv, at the calibration point of ± 2% of the range (OX-1 or OX-2, only for 316 stainless steel parts)
repetitiveness
± 1% of the measuring range
For the range of 0-10 ppmv, at the calibration point of ± 2% of the range (OX-1 or OX-2, only for 316 stainless steel parts)
resolution
± 0.1% of the measuring range
linearity
± 2% of the measuring range
Installation in non hazardous areas (safe)
Do not use a Zener safety barrier
Operating temperature
32°F ~113°F (0°C~45°C)
Environmental temperature impact
Within the entire operating temperature range, within ± 3% of the reading
Sampling gas pressure
Discharged into the atmosphere during operation and calibration
Atmospheric pressure impact
Each millimeter of mercury is ± 0.13% of the reading (proportional to pressure), and during calibration, the pressure and flow rate must be constant.
process connection
316 stainless steel and Delrin process components 1/8 "NPT (inlet and outlet)
Environmental air monitoring device: none